Eaton AFCI Circuit Breaker Fire-Guard Combination 15A Two-Pole 120/240V 10kAIC Common Trip BR Series
Professional Arc Fault Circuit Interrupter Protection
The Eaton BR AFCI Fire-Guard Combination Circuit Breaker delivers exceptional arc fault protection and electrical safety performance for residential and commercial electrical systems. This 15A two-pole circuit breaker provides reliable arc fault detection and interruption designed for professional electricians, electrical contractors, and facility managers, offering the proven Fire-Guard technology and advanced arc fault protection that professionals trust from the global leader in intelligent power management.
Professional Features & Benefits
Arc Fault Protection Performance
- 15A Two-Pole Configuration - Provides dual-pole protection with 120/240V voltage rating for comprehensive circuit protection and electrical safety
- 10 kAIC Interrupt Rating - Delivers reliable short-circuit interrupting capacity for residential and light commercial electrical applications
- Fire-Guard Combination AFCI Technology - Advanced arc fault detection and interruption prevents electrical fires caused by dangerous arcing conditions
- Common Trip Operation - Ensures both poles trip simultaneously for two-pole 240V load applications sourced by 120/240V systems
Professional Installation & Compatibility
- Type BR Loadcenter Compatibility - Designed specifically for use with Eaton Type BR loadcenters for seamless electrical panel integration
- #14-4 AWG Cu/Al Wire Compatibility - Accommodates copper and aluminum conductors from 14 AWG to 4 AWG for versatile wiring applications
- Compact Design - Measures 6 inches length, 3.5 inches width, and 1.25 inches height with lightweight 0.45 lb construction for easy installation
Safety & Compliance
- UL 1699 Certification - Meets rigorous UL standards for arc fault circuit interrupters ensuring electrical safety and code compliance
- Federal Specifications Compliance - Complies with Federal Specifications Classification W-C375 for government and institutional applications
Technical Specifications
Amperage Rating: 15A, Voltage Rating: 120/240V, Number of Poles: Two-pole, Interrupt Rating: 10 kAIC, Trip Type: Common trip, Wire Size: #14-4 AWG Cu/Al, Series: BR, Special Features: Combination arc fault protection, Used With: Type BR Loadcenters, Dimensions: 6" L x 3.5" W x 1.25" H, Weight: 0.45 lb, Certifications: UL 1699, Compliances: Federal Specifications Classification W-C375
Installation & Usage
- Verify compatibility with Type BR loadcenter and ensure proper electrical panel preparation
- Turn off main power and verify de-energized state using appropriate electrical testing equipment
- Install AFCI circuit breaker in designated panel position following manufacturer specifications
- Connect #14-4 AWG copper or aluminum conductors to circuit breaker terminals with proper torque specifications
- Test AFCI function using test and reset buttons to verify proper arc fault protection operation
- Restore power and verify circuit operation with appropriate electrical testing procedures
Professional Applications
Ideal for:
- Residential Electrical Systems - Bedroom circuits, living areas, and family rooms requiring NEC arc fault protection
- Commercial Electrical Applications - Office buildings, retail spaces, and light commercial facilities needing arc fault safety
- Multi-Wire Branch Circuits - Two-pole applications with shared neutral conductors in residential and commercial installations
- 240V Load Applications - Electric water heaters, HVAC equipment, and appliances requiring two-pole common trip protection
- Electrical Panel Upgrades - Retrofit installations upgrading existing circuits to meet current arc fault protection codes
- New Construction Projects - Residential and commercial new builds requiring NEC compliant arc fault protection
- Electrical Safety Improvements - Fire prevention upgrades in existing electrical systems with arc fault hazard concerns
- Code Compliance Projects - Electrical installations meeting National Electrical Code arc fault circuit interrupter requirements
Fire-Guard AFCI Technology Advantage
Eaton's Fire-Guard combination AFCI technology provides superior arc fault detection and interruption capabilities, protecting against both parallel and series arcing faults that can cause electrical fires. This advanced protection technology monitors electrical waveforms continuously, distinguishing between normal electrical operations and dangerous arcing conditions, providing reliable fire prevention for residential and commercial electrical systems.
Why Choose Eaton Quality?
With over a century of electrical power management innovation, Eaton leads the industry in arc fault circuit interrupter technology and electrical safety solutions. Our UL 1699 certified AFCI circuit breakers provide the reliable fire protection and electrical safety performance that electricians, electrical contractors, and facility professionals trust worldwide, backed by rigorous testing and proven field performance in residential and commercial electrical applications.
Manufacturer Resources
Product Specs
- Amperage Rating:
- 15 A
- Catalog Notes:
- Combination Fireguard/Arc Fault, Common trip refers to two-pole 240V load application sourced by 120/240V, Independent trip refers to two-pole multi-wire, home run or shared neutral circuits.
- Certifications:
- UL 1699
- Compliances:
- Federal Specifications Classification W-C375
- Interrupt Rating:
- 10 kAIC
- Main Circuit Breaker:
- BR
- Number Of Poles:
- Two-pole
- Product Height:
- 1.25 in
- Product Length Depth:
- 6 in
- Product Type:
- Afci Circuit Breaker
- Product Weight:
- .45 lb
- Product Width:
- 3.5 in
- Special Features:
- Combination arc fault
- Trip Type:
- Common trip
- Used With:
- Type BR Loadcenters
- Voltage Rating:
- 120/240 V
- Wire Size:
- #14-4 AWG Cu/Al
- Product Group:
- Electrical
- Product Subgroup:
- Circuit Breaker
- Department:
- Electrical