Eaton Dual Function Circuit Breaker Arc Fault Ground Fault 20A Single-Pole BR Series
Professional Dual Protection Electrical Circuit Breaker
The Eaton Dual Function Circuit Breaker delivers exceptional electrical protection combining both arc fault and ground fault detection in a single 20A single-pole unit designed for residential and commercial electrical applications. This dual function AFCI/GFCI circuit breaker provides comprehensive electrical protection for branch circuits, offering the proven reliability and advanced safety technology that professional electricians and electrical contractors trust from the global leader in intelligent power management.
Professional Features & Benefits
Advanced Dual Protection Technology
- Arc Fault Circuit Interrupter (AFCI) Protection - Detects dangerous arc faults that can cause electrical fires, providing enhanced safety for branch circuit wiring
- Ground Fault Circuit Interrupter (GFCI) Protection - Protects against ground faults and electrical shock hazards in wet locations and areas requiring GFCI protection
- 20 Ampere Current Rating - Handles standard residential and light commercial electrical loads with reliable overcurrent protection
- 10kAIC Interrupt Rating - Provides robust short circuit protection capability for most residential and commercial electrical panel applications
Professional Installation Features
- Single-Pole Configuration - Standard single-pole design for 120V branch circuit protection in residential and commercial electrical panels
- Pigtail Neutral Connection - Convenient pigtail neutral wire for easy installation and proper AFCI/GFCI functionality in electrical panels
- BR Series Compatibility - Designed specifically for Eaton BR series electrical panels and load centers for seamless integration
Quality Construction & Compliance
- UL Listed Certification - Meets rigorous safety standards for electrical protection devices and code compliance requirements
- Compact Design - Space-efficient 2.9" x 2.9" x 0.9" dimensions fit standard electrical panel spaces without overcrowding
Technical Specifications
Amperage Rating: 20A, Configuration: Single-pole, Interrupt Rating: 10kAIC, Circuit Breaker Type: BR Series, Protection Type: Dual Function Arc Fault/Ground Fault, Special Features: Pigtail neutral connection, Dimensions: 2.9" L x 2.9" W x 0.9" H, Weight: 0.4 lb, Certifications: UL Listed, Product Type: Dual Circuit Breaker
Installation & Usage
- Turn off main electrical power and verify power is off using appropriate electrical testing equipment
- Remove existing circuit breaker from BR series electrical panel if replacing an existing breaker
- Install the dual function circuit breaker into the appropriate single-pole slot in the BR series panel
- Connect the pigtail neutral wire to the panel's neutral bus bar according to manufacturer specifications
- Connect the branch circuit hot wire to the circuit breaker load terminal
- Test AFCI and GFCI functions using the test and reset buttons before energizing the circuit
- Restore power and verify proper operation of both arc fault and ground fault protection functions
Professional Applications
Ideal for:
- Residential Electrical Systems - Bedroom circuits, living areas, and other locations requiring both AFCI and GFCI protection per NEC requirements
- Kitchen and Bathroom Circuits - Areas requiring ground fault protection combined with arc fault detection for comprehensive electrical safety
- Laundry Room Applications - Washing machine and dryer circuits where both arc fault and ground fault protection enhance electrical safety
- Garage and Workshop Circuits - Areas with both wet location concerns and potential arc fault hazards from power tools and equipment
- Basement and Utility Areas - Electrical circuits in areas prone to moisture while requiring arc fault protection for general use outlets
- Commercial Light Duty Applications - Office spaces, retail areas, and light commercial applications requiring dual protection functionality
- Renovation and Upgrade Projects - Electrical panel upgrades where modern dual protection is required to meet current electrical codes
- New Construction Installations - Meeting current NEC requirements for both arc fault and ground fault protection in single device
Dual Function Protection Advantage
Eaton's dual function technology combines both arc fault circuit interrupter (AFCI) and ground fault circuit interrupter (GFCI) protection in a single space-saving device. This innovative design provides comprehensive electrical safety by detecting both dangerous arc faults that can cause fires and ground faults that can cause electrical shock, making it ideal for applications where both types of protection are required by electrical codes while maximizing available panel space.
Why Choose Eaton Quality?
With over a century of electrical power management innovation, Eaton leads the industry in intelligent power solutions and electrical safety technology. Our dual function circuit breakers represent the latest advancement in electrical protection, combining proven thermal-magnetic overcurrent protection with state-of-the-art arc fault and ground fault detection. UL Listed for safety and reliability, Eaton circuit breakers are trusted by professional electricians, electrical contractors, and facility managers worldwide for their dependable performance, quality construction, and commitment to electrical safety in residential, commercial, and industrial applications.
Manufacturer Resources
Product Specs
- Amperage Rating:
- 20 A
- Certifications:
- UL Listed
- Circuit Breaker Type:
- BR
- Interrupt Rating:
- 10 kAIC
- Number Of Poles:
- Single-pole
- Product Height:
- .9 in
- Product Length Depth:
- 2.9 in
- Product Type:
- Dual Circuit Breaker
- Product Weight:
- .4 lb
- Product Width:
- 2.9 in
- Special Features:
- Pigtail neutral
- Product Group:
- Electrical
- Product Subgroup:
- Circuit Breaker
- Department:
- Electrical