Eaton GFCI Circuit Breaker 20A Single-Pole 120/240V 10kAIC BR Series Ground Fault Plug-On
Professional Ground Fault Circuit Interrupter Protection
The Eaton GFCI Circuit Breaker delivers exceptional ground fault protection and electrical safety performance for residential and commercial electrical applications. This 20A single-pole ground fault circuit interrupter provides reliable electrical protection with 5 mA sensitivity designed for professional electricians, electrical contractors, and facility managers, offering the proven reliability and advanced technology that professionals trust from the global leader in intelligent power management.
Professional Features & Benefits
Ground Fault Protection Performance
- 20 Ampere Current Rating - Professional-grade current capacity for standard residential and light commercial electrical circuits with reliable overcurrent protection
- 5 mA Ground Fault Sensitivity - Advanced ground fault detection technology provides superior electrical safety protection against dangerous ground fault conditions
- 10 kAIC Interrupt Rating - High interrupting capacity safely clears electrical faults and short circuits in typical residential and commercial electrical systems
- Single-Pole Configuration - Compact design for single-phase electrical circuits with efficient space utilization in electrical panels and load centers
Installation & Connection Features
- Plug-On Connection Design - Quick and secure installation with reliable electrical connection to panel bus bars for professional electrical installation efficiency
- Trip-to-Center Indication - Clear visual indication of tripped condition for easy identification during electrical troubleshooting and maintenance procedures
- #14-8 AWG Wire Compatibility - Accommodates standard electrical wire sizes for versatile residential and commercial wiring applications
Technical Specifications
Amperage Rating: 20A, Voltage Rating: 120/240V, Number of Poles: Single-pole, Interrupt Rating: 10 kAIC, Ground Fault Sensitivity: 5 mA, Wire Size Compatibility: #14-8 AWG, Connection Method: Plug-on, Trip Indication: Trip-to-center, Circuit Protection: Ground fault circuit interrupter, Dimensions: 4" L x 3.5" W x 1" H, Weight: 0.45 lb, Main Circuit Breaker: BRN
Installation & Usage
- Verify electrical panel compatibility and ensure power is safely disconnected before beginning GFCI circuit breaker installation
- Remove existing circuit breaker and carefully disconnect electrical wiring following proper electrical safety procedures
- Install Eaton GFCI circuit breaker by firmly pressing onto panel bus bar until secure plug-on connection is achieved
- Connect circuit wiring to GFCI breaker terminals ensuring proper wire size compatibility and secure electrical connections
- Test GFCI function using test and reset buttons to verify proper ground fault protection operation
- Restore electrical power and verify circuit operation while confirming GFCI protection is functioning correctly
Professional Applications
Ideal for:
- Residential Electrical Protection - Kitchen, bathroom, laundry room, and outdoor electrical circuits requiring ground fault protection per NEC requirements
- Commercial Electrical Safety - Office buildings, retail spaces, and light commercial facilities needing reliable ground fault circuit protection
- Wet Location Protection - Areas with moisture exposure where ground fault protection is essential for electrical safety compliance
- Electrical Panel Upgrades - Modernizing electrical systems with advanced ground fault protection technology for enhanced electrical safety
- Code Compliance Applications - Meeting National Electrical Code requirements for GFCI protection in specified electrical locations
- Electrical Renovation Projects - Upgrading existing electrical circuits with modern ground fault protection during electrical system improvements
- Professional Electrical Installation - New construction and electrical system installations requiring reliable ground fault circuit protection
- Electrical Safety Systems - Critical electrical protection applications where ground fault detection is essential for personnel safety
Ground Fault Protection Advantage
Eaton's advanced ground fault circuit interrupter technology provides superior electrical safety protection with 5 mA sensitivity detection, ensuring rapid disconnection of electrical circuits when dangerous ground fault conditions occur. The trip-to-center indication feature allows electrical professionals to quickly identify tripped conditions during troubleshooting, while the plug-on connection design ensures reliable electrical connection and efficient installation in electrical panels and load centers.
Why Choose Eaton Quality?
Eaton's century-plus experience in electrical power management innovation delivers proven reliability and electrical safety performance that electricians, electrical contractors, and facility professionals trust worldwide. Our commitment to electrical safety standards, UL/CSA certification compliance, and advanced ground fault protection technology ensures dependable electrical protection for residential and commercial applications, backed by Eaton's reputation for quality construction and intelligent power management solutions.
Manufacturer Resources
Product Specs
- Amperage Rating:
- 20 A
- Certifications:
- Contact Manufacturer
- Circuit Protection:
- Ground fault circuit interrupter
- Connection:
- Plug-on
- Indicators:
- GFI
- Interrupt Rating:
- 10 kAIC
- Main Circuit Breaker:
- BRN
- Mounting Method:
- Plug-on
- Number Of Poles:
- Single-pole
- Product Height:
- 1 in
- Product Length Depth:
- 4 in
- Product Weight:
- .45 lb
- Product Width:
- 3.5 in
- Protection:
- 5 mA
- Trip Rating:
- 20 A
- Trip Type:
- Trip-to-center
- Voltage Rating:
- 120/240 V
- Wire Size:
- #14-8 AWG
- Product Type:
- Gfci Circuit Breaker
- Product Group:
- Electrical
- Product Subgroup:
- Circuit Breaker
- Department:
- Electrical