Eaton Dual Function Arc Fault Ground Fault Circuit Breaker
Professional Electrical Protection Equipment
The Eaton Dual Function Arc Fault Ground Fault Circuit Breaker delivers exceptional electrical power management and control performance for residential and commercial electrical protection applications. This 15A single-pole dual function circuit breaker provides reliable electrical protection designed for professional electricians, electrical contractors, and facility managers, offering the proven reliability and advanced technology that professionals trust from the global leader in intelligent power management.
Professional Features & Benefits
Advanced Electrical Protection
- 15A Single-Pole Configuration - Provides precise current protection with single-pole design for 120V branch circuits and residential electrical applications
- Dual Function AF/GF Protection - Combines arc fault and ground fault protection in one device for comprehensive electrical safety and code compliance
- 10kAIC Interrupt Rating - Delivers reliable short circuit protection with 10,000 ampere interrupting capacity for residential electrical systems
- CH Series Compatibility - Engineered specifically for Eaton CH load centers and electrical panels for seamless professional installation
Installation & Connection Features
- Pigtail Connection Design - Features pigtail wiring connection for flexible installation and neutral wire connection in electrical panels
- UL Listed Certification - Meets rigorous electrical safety standards and code requirements for professional electrical installations
- Compact Design - Measures 4.5" x 3.25" x 0.75" with 0.5 lb weight for space-efficient panel installation
Technical Specifications
Amperage Rating: 15A, Number of Poles: Single-pole, Interrupt Rating: 10kAIC, Circuit Breaker Type: CH Series, Connection: Pigtail, Dimensions: 4.5" L x 3.25" H x 0.75" W, Weight: 0.5 lb, Certifications: UL Listed, Product Type: Dual Function Arc Fault/Ground Fault Circuit Breaker
Installation & Usage
- Verify power is OFF and test electrical panel with appropriate safety equipment before installation
- Remove existing circuit breaker from CH load center and disconnect branch circuit wiring
- Install dual function breaker into designated panel slot ensuring proper alignment with bus bar connection
- Connect branch circuit hot wire to breaker terminal and pigtail neutral wire to panel neutral bar
- Verify all connections are secure and properly torqued according to manufacturer specifications
- Test breaker operation using test and reset buttons before restoring power to circuit
Professional Applications
Ideal for:
- Residential Electrical Systems - Bedroom circuits, living areas, and other locations requiring AFCI/GFCI protection per NEC requirements
- Kitchen and Bathroom Circuits - Areas requiring ground fault protection combined with arc fault detection for comprehensive safety
- Bedroom and Living Area Protection - Branch circuits serving outlets in bedrooms, family rooms, and similar residential spaces
- Code Compliance Applications - Installations requiring dual function protection to meet current National Electrical Code standards
- Electrical Panel Upgrades - Retrofit applications upgrading existing CH panels with enhanced arc fault and ground fault protection
- New Construction Projects - Residential electrical installations requiring modern safety protection in CH load centers
- Electrical Safety Systems - Applications prioritizing occupant protection from electrical fires and shock hazards
- Professional Electrical Installations - Commercial and residential projects requiring reliable dual function circuit protection
Dual Function Protection Advantage
The dual function design combines arc fault circuit interrupter (AFCI) and ground fault circuit interrupter (GFCI) protection in a single device, providing comprehensive electrical safety by detecting dangerous arc faults that can cause electrical fires while simultaneously protecting against ground faults that can cause electrical shock, making it ideal for modern electrical installations requiring both types of protection.
Why Choose Eaton Quality?
Eaton's century-plus experience in electrical power management innovation, commitment to electrical safety and reliability, UL Listed certification, and trusted performance for electricians, electrical contractors, and facility professionals worldwide. The CH series represents decades of proven electrical protection technology with advanced dual function capabilities that meet the evolving needs of modern electrical systems and safety codes.
Manufacturer Resources
Product Specs
- Amperage Rating:
- 15 A
- Application:
- CH Dual Function AF/GF Breaker, 15A, Pigtail, 10kAIC
- Certifications:
- UL Listed
- Circuit Breaker Type:
- CH
- Connection:
- Pigtail
- Interrupt Rating:
- 10 kAIC
- Number Of Poles:
- Single-pole
- Product Height:
- 3.25 in
- Product Length Depth:
- 4.5 in
- Product Type:
- Dual Circuit Breaker
- Product Weight:
- .5 lb
- Product Width:
- .75 in
- Product Group:
- Electrical
- Product Subgroup:
- Circuit Breaker
- Department: