Eaton GFCI Circuit Breaker 60A Two-Pole 120/240V 10kAIC CH Series Ground Fault Self-Test
Professional Ground Fault Circuit Interrupter Protection
The Eaton CH Series GFCI Circuit Breaker delivers exceptional electrical protection and ground fault interruption for residential and commercial electrical systems. This 60A two-pole 120/240V circuit breaker with 10kAIC interrupt rating provides reliable ground fault protection designed for professional electricians, electrical contractors, and facility managers, offering the proven reliability and advanced ground fault self-test technology that professionals trust from the global leader in intelligent power management.
Professional Features & Benefits
Ground Fault Protection Performance
- 60A Two-Pole Configuration - High-capacity ground fault protection for 240V circuits including water heaters, pool equipment, and heavy-duty appliances requiring GFCI protection
- 10kAIC Interrupt Rating - Professional-grade interrupting capacity for reliable fault clearing in residential and light commercial electrical systems
- 120/240V Voltage Rating - Dual voltage capability for versatile installation in split-phase electrical panels and load centers
- Ground Fault Self-Test Technology - Advanced self-testing capability ensures continuous GFCI protection reliability and compliance with latest electrical safety standards
Installation & Connection Features
- Plug-On Connection Design - Quick and secure installation with CH series load centers and electrical panels for efficient electrical contractor installation
- #14-4 AWG Wire Compatibility - Accommodates wide range of wire sizes for flexible electrical system design and professional wiring applications
- Common Trip Operation - Both poles trip simultaneously for complete circuit isolation and enhanced electrical safety protection
Technical Specifications
Amperage Rating: 60A, Voltage Rating: 120/240V, Number of Poles: Two-pole, Interrupt Rating: 10kAIC, Series: CH, Trip Type: Common, Connection: Plug-on, Wire Size: #14-4 AWG, Special Features: Ground Fault Self Test, Circuit Protection: Ground fault self test, Certifications: UL 489, Product Dimensions: 4.5" L x 2.75" W x 2" H, Weight: 0.7 lb, Federal Spec Classification: W-C375
Installation & Usage
- Verify electrical panel compatibility with CH series circuit breakers and confirm proper voltage rating
- Turn off main electrical power and verify de-energized state using appropriate electrical testing equipment
- Remove knockout from electrical panel and position GFCI breaker in designated two-pole space
- Connect load wires to GFCI breaker terminals according to manufacturer wiring diagram and local electrical codes
- Plug breaker onto panel bus bars ensuring secure mechanical and electrical connection
- Test GFCI function using test and reset buttons before energizing circuit and placing into service
Professional Applications
Ideal for:
- Residential GFCI Protection - Water heater circuits, pool and spa equipment, outdoor receptacles, and bathroom/kitchen appliance circuits requiring ground fault protection
- Commercial Ground Fault Applications - Restaurant equipment, outdoor lighting systems, construction temporary power, and wet location electrical installations
- Pool and Spa Electrical Systems - Pump motors, heaters, lighting systems, and other pool equipment requiring GFCI protection per NEC requirements
- Outdoor Electrical Circuits - Landscape lighting, outdoor receptacles, irrigation systems, and exterior electrical equipment installations
- Bathroom and Kitchen Circuits - High-amperage appliance circuits in wet locations requiring ground fault circuit interrupter protection
- Workshop and Garage Applications - Power tool circuits, electric vehicle charging, and other high-current applications in potentially wet environments
- Construction and Temporary Power - Job site electrical distribution, temporary electrical services, and construction equipment power feeds
- Industrial Wet Location Protection - Manufacturing equipment, wash-down areas, and industrial processes requiring ground fault protection
Ground Fault Self-Test Advantage
The integrated ground fault self-test technology automatically verifies GFCI protection functionality, ensuring continuous electrical safety compliance and reducing maintenance requirements. This advanced feature provides peace of mind for electrical professionals and building owners by confirming proper ground fault protection operation without manual testing, meeting the latest electrical safety standards and NEC requirements for GFCI reliability.
Why Choose Eaton Quality?
Eaton's century-plus experience in electrical power management innovation delivers the reliability and performance that electrical professionals demand. With UL 489 certification and compliance with Federal Spec Classification W-C375, this CH series GFCI circuit breaker represents Eaton's commitment to electrical safety and quality construction. Trusted by electricians, electrical contractors, and facility professionals worldwide, Eaton continues to lead in ground fault protection technology and intelligent power management solutions for residential, commercial, and industrial electrical applications.
Manufacturer Resources
Product Specs
- Amperage Rating:
- 60 A
- Catalog Notes:
- Meets Federal Spec Classification W-C375
- Certifications:
- UL 489
- Circuit Protection:
- Ground fault self test
- Connection:
- Plug-on
- Indicators:
- GFI
- Interrupt Rating:
- 10 kAIC
- Main Circuit Breaker:
- CH
- Number Of Poles:
- Two-pole
- Product Height:
- 2 in
- Product Length Depth:
- 4.5 in
- Product Type:
- Gfci Circuit Breaker
- Product Weight:
- .7 lb
- Product Width:
- 2.75 in
- Special Features:
- Ground Fault Self Test
- Trip Type:
- Common
- Voltage Rating:
- 120/240 V
- Wire Size:
- #14-4 AWG
- Product Group:
- Electrical
- Product Subgroup:
- Circuit Breaker
- Department:
- Electrical