Eaton GFCI Circuit Breaker 40A Two-Pole 120/240V 10kAIC Plug-In CH Series Common Trip 5mA

(No reviews yet) Write a Review

Model: CHN240GF

In Stock (leaves warehouse same day if ordered before 3pm ET)

$257.79
$199.87
Adding to cart… The item has been added
Free Shipping on orders over $99
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Eaton CH GFCI Circuit Breaker 40A Two-Pole 120/240V

Professional Ground Fault Circuit Interrupter Protection

The Eaton CH GFCI Circuit Breaker delivers exceptional electrical protection and ground fault circuit interruption for residential and commercial electrical systems. This 40A two-pole 120/240V circuit breaker with 10kAIC interrupt rating provides reliable ground fault protection designed for professional electricians, electrical contractors, and facility managers, offering the proven reliability and advanced GFCI technology that professionals trust from the global leader in intelligent power management.

Professional Features & Benefits

Ground Fault Protection Performance

  • 40A Two-Pole Configuration - Provides robust current capacity for high-demand 240V circuits including water heaters, electric dryers, and HVAC equipment requiring GFCI protection
  • 5mA Ground Fault Sensitivity - Advanced ground fault detection technology trips at 5 milliamps to protect against dangerous ground faults and electrical shock hazards
  • 10kAIC Interrupt Rating - Professional-grade interrupting capacity handles fault currents up to 10,000 amperes for reliable circuit protection in residential and light commercial applications
  • 120/240V Voltage Rating - Dual voltage capability protects both line-to-neutral and line-to-line circuits in standard residential electrical systems

Installation & Safety Features

  • Plug-In Design - Quick and secure installation into CH series load centers with positive connection to panel bus bars
  • Common Trip Operation - Both poles trip simultaneously for complete circuit isolation and enhanced electrical safety protection
  • UL 489 Certified - Meets rigorous safety standards for molded case circuit breakers ensuring professional electrical code compliance

Technical Specifications

Amperage Rating: 40A, Voltage Rating: 120/240V, Number of Poles: Two-pole, Interrupt Rating: 10kAIC, Trip Type: Common, Ground Fault Sensitivity: 5mA, Series: CH, Mounting: Plug-in, Dimensions: 6" L x 3.5" W x 2.25" H, Weight: 0.8 lb, Certifications: UL 489

Installation & Usage

  1. Verify electrical panel compatibility with CH series circuit breakers and confirm proper voltage rating
  2. Turn off main power and verify de-energized state using appropriate electrical testing equipment
  3. Remove knockout from electrical panel and position GFCI breaker in designated two-pole space
  4. Connect hot conductors to breaker terminals ensuring proper torque specifications per manufacturer requirements
  5. Connect neutral conductor to breaker neutral terminal and equipment grounding conductor to panel ground bar
  6. Test GFCI function using test and reset buttons before energizing circuit and placing into service

Professional Applications

Ideal for:

  • Residential GFCI Protection - Water heater circuits, electric dryer circuits, and outdoor receptacle circuits requiring ground fault protection
  • Bathroom and Kitchen Circuits - High-amperage appliance circuits in wet locations where GFCI protection is required by electrical code
  • Pool and Spa Equipment - Pump motors, heaters, and electrical equipment serving swimming pools and hot tubs requiring GFCI protection
  • Outdoor Electrical Systems - Exterior lighting, receptacles, and equipment circuits exposed to moisture requiring ground fault protection
  • Commercial Wet Locations - Restaurant equipment, laundry facilities, and commercial kitchen circuits requiring GFCI protection
  • Workshop and Garage Circuits - High-amperage tool circuits and equipment in areas where ground fault protection enhances electrical safety
  • HVAC Equipment Protection - Air conditioning units, heat pumps, and ventilation equipment requiring both overcurrent and ground fault protection
  • Electric Vehicle Charging - Dedicated circuits for EV charging stations requiring GFCI protection per electrical code requirements

CH Series Advantage

The CH series represents Eaton's commitment to residential and light commercial electrical protection with proven thermal-magnetic trip technology combined with advanced ground fault circuit interruption. This plug-in design ensures quick installation and reliable connection to CH load centers, while the common trip mechanism provides complete circuit isolation for enhanced electrical safety in ground fault conditions.

Why Choose Eaton Quality?

With over a century of electrical power management innovation, Eaton delivers the reliability and safety performance that electrical professionals demand. Our UL 489 listed circuit breakers undergo rigorous testing to ensure dependable protection, while our commitment to electrical safety standards and professional-grade construction makes Eaton the trusted choice for electricians, electrical contractors, and facility professionals worldwide who require proven ground fault protection technology.

Manufacturer Resources

Product Specs

Amperage Rating:
40 A
Certifications:
UL 489
Indicators:
GFI
Interrupt Rating:
10 kAIC
Main Circuit Breaker:
CH
Number Of Poles:
Two-pole
Product Height:
2.25 in
Product Length Depth:
6 in
Product Type:
Gfci Circuit Breaker
Product Weight:
.8 lb
Product Width:
3.5 in
Protection:
5 mA
Trip Type:
Common
Voltage Rating:
120/240 V
Product Group:
Electrical
Product Subgroup:
Circuit Breaker
Department:
Electrical

Eaton CHN240GF – Frequently Asked Questions

How fast can I get the Eaton CHN240GF delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Eaton CHN240GF come with a warranty?
Absolutely. The Eaton CHN240GF is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Eaton CHN240GF?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Eaton CHN240GF from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.