Eaton CH Thermal Magnetic Circuit Breaker Type CHF
Professional 30A Two-Pole Circuit Protection with Trip Flag Indication
The Eaton CH Thermal Magnetic Circuit Breaker Type CHF delivers exceptional electrical protection performance for residential and commercial electrical systems. This 30A two-pole 120/240V circuit breaker provides reliable thermal-magnetic protection designed for professional electricians, electrical contractors, and facility managers, offering the proven reliability and advanced technology that professionals trust from the global leader in intelligent power management.
Professional Features & Benefits
Thermal-Magnetic Protection Performance
- 30 Ampere Rating - Provides reliable overcurrent protection for medium-load residential and commercial circuits with precise thermal-magnetic trip characteristics
- Two-Pole Common Trip Design - Ensures simultaneous disconnection of both poles for enhanced electrical safety and code compliance in 240V applications
- 10 kAIC Interrupt Rating - Delivers dependable short-circuit protection capability for standard residential and light commercial electrical installations
- 120/240V Voltage Rating - Compatible with standard residential electrical systems and split-phase power distribution applications
Professional Installation & Safety Features
- Trip Flag Indication - Visual trip indicator provides immediate identification of tripped breakers for faster troubleshooting and electrical system maintenance
- 3/4-Inch Width Design - Space-efficient form factor maximizes panel capacity while maintaining full electrical protection performance
- Type CH Loadcenter Compatibility - Engineered specifically for Eaton Type CH electrical panels ensuring proper fit and optimal electrical performance
Technical Specifications
Amperage Rating: 30A, Voltage Rating: 120/240V, Number of Poles: Two-pole, Interrupt Rating: 10 kAIC, Circuit Breaker Type: CHF, Trip Type: Trip flag indication, Wire Size: (1) #14-8 AWG, Product Dimensions: 2.6" H x 0.75" W x 1.5" D, Weight: 0.28 lb, Certifications: UL 489, Compliances: HACR Rated, Used With: Type CH Loadcenters, Common Trip: Yes
Installation & Usage
- Verify power is completely disconnected from the electrical panel and test with appropriate electrical testing equipment
- Remove panel cover and identify appropriate two adjacent 3/4-inch breaker spaces in Type CH loadcenter
- Install CHF circuit breaker by engaging mounting clip with panel bus and pressing firmly until fully seated
- Connect circuit wiring to breaker terminals using appropriate wire sizes (#14-8 AWG) and proper torque specifications
- Verify proper breaker operation by testing trip flag function and reset mechanism before energizing circuit
- Replace panel cover and label circuit directory with appropriate circuit identification for future maintenance
Professional Applications
Ideal for:
- Residential Electrical Systems - Kitchen appliance circuits, electric water heaters, air conditioning units, and other 240V household equipment protection
- Commercial Building Applications - Small commercial HVAC systems, lighting panels, and general power distribution in office buildings and retail spaces
- Split-Phase Power Distribution - Two-pole protection for 240V loads requiring common trip operation and simultaneous disconnection
- HACR Rated Applications - Heating, air conditioning, and refrigeration equipment protection with specialized motor load characteristics
- Electrical Panel Upgrades - Replacement and modernization of existing circuit protection in Type CH electrical distribution systems
- Code Compliance Projects - Meeting NEC requirements for two-pole protection in residential and commercial electrical installations
- Maintenance and Repair - Professional electrical service work requiring reliable circuit protection with visual trip indication
- New Construction - Electrical contractors installing complete electrical systems in residential and light commercial buildings
Trip Flag Technology Advantage
The integrated trip flag indication system provides immediate visual confirmation when the circuit breaker has operated, enabling faster electrical troubleshooting and reducing service call time. This professional feature helps electricians and facility managers quickly identify tripped breakers in electrical panels, improving electrical system maintenance efficiency and reducing downtime in critical applications.
Why Choose Eaton Quality?
Eaton's century-plus experience in electrical power management innovation ensures this CHF circuit breaker delivers the reliability and performance that electrical professionals demand. With UL 489 certification and HACR rating compliance, this thermal-magnetic circuit breaker represents Eaton's commitment to electrical safety and dependable protection, trusted by electricians, electrical contractors, and facility professionals worldwide for critical electrical power distribution and circuit protection applications.
Manufacturer Resources
Product Specs
- Amperage Rating:
- 30 A
- Catalog Notes:
- HACR Rated. Two-Pole 120/240V Common Trip Requires Two 3/4-Inch Spaces. With Trip Indication
- Certifications:
- UL 489
- Circuit Breaker Type:
- CHF
- Compliances:
- HACR Rated
- Interrupt Rating:
- 10 kAIC
- Main Circuit Breaker:
- CHF
- Number Of Poles:
- Two-pole
- Product Height:
- 2.6 in
- Product Length Depth:
- 1.5 in
- Product Type:
- Thermal Magnetic Circuit Breaker
- Product Weight:
- .28 lb
- Product Width:
- .75 in
- Trip Type:
- Trip flag
- Used With:
- Type CH Loadcenters
- Voltage Rating:
- 120/240 V
- Wire Size:
- (1) #14-8 AWG
- Product Group:
- Electrical
- Product Subgroup:
- Circuit Breaker
- Department:
- Electrical