Eaton Type CCV Tenant Main Circuit Breaker
Professional Electrical Main Breaker Protection
The Eaton Type CCV Tenant Main Circuit Breaker delivers exceptional electrical power management and control performance for tenant electrical distribution applications. This 150A two-pole main circuit breaker provides reliable electrical protection designed for professional electricians, electrical contractors, and facility managers, offering the proven reliability and advanced technology that professionals trust from the global leader in intelligent power management.
Professional Features & Benefits
Electrical Performance Excellence
- 150 Ampere Rating - High-capacity current handling for demanding tenant electrical distribution systems with reliable overcurrent protection
- Two-Pole Configuration - Dual-pole design provides simultaneous protection for both hot conductors in 120/240V electrical systems
- 10 kAIC Interrupt Rating - Professional-grade interrupting capacity safely clears fault currents up to 10,000 amperes for enhanced electrical safety
- 120/240V Voltage Rating - Versatile voltage compatibility for standard residential and light commercial electrical applications
Professional Installation & Protection
- Type ECC Unit Enclosure Compatibility - Engineered specifically for Type ECC unit enclosures ensuring proper fit and electrical performance
- Wire Size Flexibility - Accommodates #2/0 AWG through 300 kcmil copper and aluminum conductors for versatile installation options
- UL 489 Certified - Meets rigorous UL safety standards for molded case circuit breakers ensuring code compliance and electrical safety
Technical Specifications
Amperage Rating: 150A, Voltage Rating: 120/240V, Number of Poles: Two-pole, Interrupt Rating: 10 kAIC, Wire Size: #2/0 AWG-300 kcmil Cu/Al, Main Circuit Breaker Type: CCV, Used With: Type ECC Unit Enclosures, Certifications: UL 489, Product Dimensions: 7.7" L x 5.4" H x 4.5" W, Product Weight: 2.9 lb, Terminal Type: Standard lugs suitable for copper or aluminum wire
Installation & Usage
- Verify electrical system compatibility with 150A two-pole main breaker requirements and 120/240V voltage rating
- Ensure Type ECC unit enclosure is properly prepared and meets installation specifications
- Install circuit breaker in designated main breaker position following manufacturer guidelines and local electrical codes
- Connect incoming service conductors to main breaker terminals using appropriate wire sizes (#2/0 AWG-300 kcmil Cu/Al)
- Verify proper torque specifications for terminal connections and ensure secure electrical connections
- Test circuit breaker operation and verify proper electrical protection functionality before energizing system
Professional Applications
Ideal for:
- Tenant Electrical Distribution - Primary main breaker protection for individual tenant electrical service in multi-tenant buildings
- Commercial Electrical Systems - Main overcurrent protection for small to medium commercial electrical installations
- Residential Service Panels - Main breaker applications in residential electrical distribution systems requiring 150A capacity
- Light Industrial Applications - Electrical protection for light industrial facilities and workshop electrical systems
- Electrical Service Upgrades - Replacement main breakers for electrical system modernization and capacity improvements
- Multi-Family Housing - Individual unit main protection in apartment complexes and condominium electrical systems
- Small Business Electrical - Main electrical protection for retail stores, offices, and small commercial establishments
- Electrical Safety Systems - Primary overcurrent protection ensuring electrical safety and code compliance
CCV Type Design Advantage
The CCV type design provides specialized tenant main circuit breaker functionality with optimized performance for Type ECC unit enclosures. This professional-grade design ensures reliable electrical protection with standard lug terminals suitable for both copper and aluminum conductors, offering installation flexibility while maintaining superior electrical performance and safety standards.
Why Choose Eaton Quality?
Eaton's century-plus experience in electrical power management innovation delivers unmatched reliability and performance. With rigorous UL 489 certification and commitment to electrical safety standards, Eaton main circuit breakers provide the trusted performance that electricians, electrical contractors, and facility professionals depend on worldwide for critical electrical protection applications.
Manufacturer Resources
Product Specs
- Amperage Rating:
- 150 A
- Catalog Notes:
- Terminals-standard lugs (wire connectors) suitable for copper or aluminum wire.
- Certifications:
- UL 489
- Circuit Breaker Frame Type:
- CCV
- Interrupt Rating:
- 10 kAIC
- Main Circuit Breaker:
- CCV
- Number Of Poles:
- Two-pole
- Product Height:
- 5.4 in
- Product Length Depth:
- 7.7 in
- Product Type:
- Main Breaker
- Product Weight:
- 2.9 lb
- Product Width:
- 4.5 in
- Used With:
- Type ECC Unit Enclosures
- Voltage Rating:
- 120/240 V
- Wire Size:
- #2/0 AWG-300 kcmil Cu/Al
- Product Group:
- Electrical
- Product Subgroup:
- Circuit Breaker
- Department:
- Electrical