Hager 4501 Series Fire Rated Surface Vertical Rod Exit Device - 48" Wide Stile Grade 1
Heavy-Duty Commercial Fire Safety Solution
The Hager 4501 Series Fire Rated Surface Vertical Rod Exit Device delivers Grade 1 performance for demanding commercial applications. This 48" wide stile device features extruded aluminum construction with stainless steel components and is UL/cUL Listed for up to 3 hours fire rating. Designed for door widths field sizeable to 36" with minimum stile width requirements of 5-3/8" for single doors, this exit device meets ANSI/BHMA A156.3-2014 Grade 1 certification and provides dead locking stainless steel Pullman type latchbolts for premium security.
Professional Features & Benefits
- Fire Rating Performance: UL/cUL Listed for up to 3 hours fire rating on "A" label single doors with UL10C Positive Pressure and UL10B Neutral Pressure ratings.
- Grade 1 Durability: ANSI/BHMA A156.3-2014 Grade 1 certified for heavy-duty commercial applications with lifetime warranty coverage when properly applied and maintained.
- Wide Door Compatibility: 48" device field sizeable to 36" for panic or fire-rated doors with minimum stile width of 5-3/8" for single doors.
- Premium Construction: Extruded aluminum construction with stainless steel push bar cover, die cast caps and covers for superior durability and performance.
- Secure Latching System: Dead locking stainless steel Pullman type latchbolts with 3/4" throw and automatic dead-latching for enhanced security.
- Hurricane Zone Approval: Meets ANSI requirements as Severe Windstorm Components and approved for High Velocity Hurricane Zone areas with Miami-Dade County NOA certification.
- Flexible Dogging Options: Standard hex key dogging with optional cylinder dogging available for operational convenience.
- Multiple Finish Options: Available in US3, US4, US10B, US26, US26D, US32D, and BLK finishes to match architectural requirements.
Technical Specifications
- ADA Compliant: No
- ANSI/BHMA: ANSI A156.3-2014
- Applications: Heavy Duty Commercial
- Certifications: ANSI/BHMA A156.3-2014 Grade 1
- Commercial/Residential: Commercial
- Cover: Stainless steel, zinc
- Cylinder and Keyways: Rim
- Dogging: Hex key dogging standard on panic rated devices
- Door Thickness: 1-3/4" (44mm) - Standard up to 3", except with night latch which is 2-1/2".
- Door Width: 6'' (914mm) field sizeable to 30'' (762 mm) panic-rated door and 28" (711mm) fire-rated door
- Ends Caps: Standard end cap (zinc)
- Fasteners: Wood and machine screws
- Features: Provide Necessary Security and Performance At Economy Pricing
- Finishes: US3, US4, US10B, US26, US26D, US32D, BLK;
- Fire Rating: Yes
- Functions: 1 - Exit Only (device)
- Grade: Grade 1
- Lock Type: 3/4" (19mm) throw, pullman type with automatic dead-latching, stainless steel
- Notes: Recommended to be used on appropriately reinforced doors
- Projection: 3" (76mm) in undogged position
- Series: 4501
- Stile Width: 5-3/8" (137mm) - Minimum stile width required for single doors and standard 5/8" (16 mm) stop
- Strikes: Stainless steel with plated rollers - Included standard with panic devices
- Subcategory: Rim Exit Devices
- Trim: Archer, August, Charles, Johnston, Joshua, Louis, Warren, William or Withnell lever with escutcheon
Installation & Operation
- Review manufacturer specifications and verify door preparation requirements including door thickness (1-3/4" standard up to 3"), stile width (minimum 5-3/8" for single doors), and door width compatibility.
- Use manufacturer-provided templates to mark mounting hole locations accurately on door and frame surfaces for the surface vertical rod configuration.
- Prepare door and frame by drilling required holes and routing as specified in manufacturer instructions for the vertical rod mechanism and strike installation.
- Install all mounting hardware including the vertical rod assembly and secure the device to door and frame per manufacturer torque specifications using provided wood screws, machine screws, or thru-bolts as appropriate.
- Adjust operational components for proper alignment, latching, and smooth operation throughout the full range of motion, ensuring proper engagement of the dead locking Pullman type latchbolts.
- Test device operation to verify proper function including panic operation, dogging mechanism, and fire rating compliance. Make final adjustments as needed and refer to manufacturer documentation for complete installation details.
Professional Applications
- Heavy-Duty Commercial Office Buildings
- Medical Facilities and Healthcare Institutions
- Educational Facilities and Schools
- Hospitality Structures and Hotels
- Fire-Rated Door Applications
- Hurricane Zone and High Wind Areas
- Multi-Tenant Commercial Properties
Why Choose Hager Quality?
Hager 4501 Series Exit Devices deliver professional-grade reliability with extruded aluminum construction and stainless steel components engineered for heavy-duty commercial applications. ANSI/BHMA Grade 1 certification and UL fire rating up to 3 hours ensure code compliance and life safety performance. Backed by a lifetime warranty when properly applied and maintained, providing confidence from distributor to building owner in demanding commercial environments.
Grade 1 mortise exit device with integrated mortise lock chassis for superior security in high-traffic commercial openings.Manufacturer Resources
Product Specs
- ADA Compliant:
- No
- Grade:
- Grade 1
- Application:
- Heavy Duty Commercial
- ANSI/BHMA:
- ANSI A156.3-2014
- Product Group:
- Exit Devices and Trim
- Product Subgroup:
- Exit Devices - Rim
- Product Type:
- Exit Devices - Rim
- Subcategory:
- Rim Exit Devices
- Features:
- Provide Necessary Security and Performance At Economy Pricing
- Commercial/Residential:
- Commercial
- Cylinder and Keyways:
- Rim
- Series:
- 4501
- Product Model:
- 4501 SVR
- Product Size:
- 48"
- Dogging Configuration:
- Hex Key Dogging
- Fire Rating:
- Yes
- Product Substrate:
- Zinc, Stainless Steel
- Product Category:
- Exit Devices and Trim
- Department:
- Door Hardware