LCN 8310 Series Senior Swing Independent Pair Sensor Package with Header and Door Mount Sensors
Complete Healthcare Touchless Activation System
The LCN 8310-3892 Senior Swing Independent Pair Package provides a comprehensive touchless activation solution specifically designed for healthcare environments. This complete system includes (2) 8310-877 header mount sensors, (2) 8310-877S header mount spacers, (4) 8310-804-2 door mount sensors for approach and safety side coverage, and (2) 8310-847 harnesses for seamless integration with Senior Swing automatic door operators. The touchless technology allows pedestrians to simply wave their hand in front of the sensor to activate door operation without any physical contact with actuators, door handles, or push bars.
Professional Features & Benefits
- Complete System Package: Includes all necessary components - (2) header sensors, (2) spacers, (4) door safety sensors, and (2) harnesses for independent pair door configurations.
- Touchless Activation Technology: Motion-sensing technology acknowledges intent to enter without requiring contact with actuators, door handles, push bars, or doors for enhanced hygiene.
- Healthcare-Specific Design: Health Care II configuration optimized for medical facility requirements with approach and safety side sensor coverage.
- Senior Swing Compatibility: Engineered specifically for use with Senior Swing automatic door operators with dedicated harness connections.
- Independent Pair Configuration: Designed for dual-door installations with separate sensor control for each door leaf.
- Professional Installation Components: Includes header mount spacers and proper harnesses for clean, code-compliant installations.
- Enhanced Safety Coverage: Four door mount sensors provide comprehensive approach and safety side monitoring for pedestrian protection.
Technical Specifications
- Refer to manufacturer documentation for complete technical specifications.
Installation & Operation
- Verify electrical requirements match available power supply and confirm compatibility with existing Senior Swing automatic door operator systems.
- Disconnect power supply before beginning installation. Follow all applicable electrical codes and safety procedures.
- Mount header sensors in specified locations ensuring adequate clearance for wiring access and proper detection zone coverage.
- Install header mount spacers as required for proper sensor positioning and alignment with door operation.
- Position door mount sensors on both approach and safety sides according to manufacturer templates and healthcare facility requirements.
- Route and connect wiring using provided harnesses according to manufacturer wiring diagrams. Use appropriate connections for the application.
- Configure operational settings including detection zones and timing per healthcare application requirements.
- Restore power and test all functions including normal activation, safety sensor operation, and integration with Senior Swing door operators.
- Complete final inspection and document settings. Refer to manufacturer documentation for complete wiring diagrams, programming instructions, and troubleshooting.
Professional Applications
- Healthcare Institutions and Medical Centers
- Hospital Patient Care Areas
- Medical Office Buildings
- Assisted Living Facilities
- Rehabilitation Centers
- Emergency Department Entrances
- Clean Room and Sterile Environment Access
Why Choose LCN Quality?
LCN 8310 Series sensor packages deliver professional-grade touchless activation technology engineered specifically for demanding healthcare applications. The comprehensive package design ensures all necessary components are included for complete independent pair installations. Designed for seamless integration with Senior Swing automatic door operators where reliable, hygienic access control is essential for patient and staff safety.
Product Documentation & Resources
- [Catalog] LCN Full Line Catalog
- [Catalog] LCN Automatic Operators Catalog
- [Installation Guide] 8310-813 Touchless Actuator Install
- [Installation Guide] 8310-806KP Remote Switch Install
- [Installation Guide] 8310-876 6" Escutcheon Install
- [Installation Guide] 8310-889 Safety Module Install
- [Installation Guide] 8310-845 Time-Delay Module Install
- [Installation Guide] 8310-865 433 MHz Transmitters/Receivers Install
- [Installation Guide] 8310-877 Header-Mounted Safety Sensor Install
- [Installation Guide] 8310-866 Bollard Install
- [Installation Guide] 8310-852WP/853WP Wireless Push Plates Install
- [Spec Sheet] LCN Actuators and Sensors Data Sheet
- [Sell Sheet] LCN Senior Swing Product Brochure
- [Parts Manual] LCN Closers & Auto Operators Parts Manual
Manufacturer Resources
Product Specs
- Series:
- 8310 Series
- Application:
- Used with 8310-877 (2) Header Mount Sensor, 8310-877S (2) Header Mount Spacer, 8310-804-2 (4) Door Mount Sensor (approach/safety side), 8310-847 (2) Harness (Used with Senior Swing only)
- Subcategory:
- Closer Parts and Accessories
- Product Group:
- Electronic Access Controls
- Product Subgroup:
- Parts and Accessories
- Product Type:
- Safety Packages
- Commercial/Residential:
- Commercial
- Electronic:
- Yes
- ADA Compliant:
- Yes
- Parts and Accessories Type:
- Installation Accessories
- Product Attribute:
- Parts and Accessories
- Package:
- Yes
- Package Qnty:
- 10
- Product Model:
- 8310-3892C
- Product Category:
- Electronic Access Controls
- Department:
- Door Hardware