Generac Air Cooled Oil Heater ...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$281.04

Generac Air Cooled Oil Heater Cold Weather Accessory 7102 Generator Compatibility

(No reviews yet) Write a Review

Model: 7102
Selected Model is

In Stock (leaves warehouse same day if ordered before 3pm ET)

$281.04
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Generac Air Cooled Oil Heater Cold Weather Accessory

Professional Generator Cold Weather Protection System

The Generac Air Cooled Oil Heater delivers essential cold weather protection for reliable generator operation in freezing temperatures. This professional cold weather accessory provides dependable oil warming solutions designed for Generac generators manufactured 2008 to present, offering the proven reliability and advanced engineering that customers trust from America's leading generator manufacturer for consistent backup power performance.

Professional Features & Benefits

Cold Weather Performance

  • Temperature Protection Below 32°F - Recommended for locations that regularly experience freezing temperatures, ensuring reliable generator starting and operation during cold weather conditions
  • Direct Oil Filter Installation - Oil warmer slips directly under the oil filter for efficient heat transfer and optimal oil warming performance
  • 2008-Present Compatibility - Only compatible with Generac units manufactured from 2008 to present, ensuring proper fit and reliable operation
  • CSA Certified Safety - Professional certification ensures safe operation and compliance with electrical safety standards

Installation & Operation

  • Professional Installation Requirements - Requires 5W-30 synthetic oil replacement when installing any cold weather accessories for optimal performance
  • Compact Design - Measures 10.0 inches length, 6.0 inches width, 3.0 inches height with 6.0 lbs assembled weight for efficient installation
  • Durable Construction - Orange finish with rubber frame material for weather resistance and long-term reliability

Technical Specifications

Dimensions: 10.0" L x 6.0" W x 3.0" H, Weight: 6.0 lbs assembled (2.0 lbs unit weight), Frame Material: Rubber construction, Color: Orange finish, Compatibility: Generac generators manufactured 2008 to present, Certification: CSA Certified, Installation: Direct oil filter mounting, Required Oil: 5W-30 synthetic oil replacement, Warranty: 1 Year Limited Parts, Country of Origin: United States, CARB Compliant: Yes

Installation & Operation

  1. Verify generator compatibility with 2008 or newer Generac manufacturing date
  2. Position oil heater directly under existing oil filter location
  3. Secure heater assembly according to installation instructions
  4. Replace existing oil with 5W-30 synthetic oil as required for cold weather operation
  5. Connect electrical connections following CSA certified installation procedures
  6. Test heater operation before cold weather season begins

Professional Applications

Ideal for:

  • Cold Climate Backup Power - Essential for homes and businesses in regions with regular freezing temperatures
  • Winter Emergency Preparedness - Ensures reliable generator starting during winter power outages and emergency situations
  • Commercial Cold Weather Operations - Critical for businesses requiring dependable backup power in cold climates
  • Remote Location Generators - Perfect for generators in unheated locations exposed to freezing temperatures
  • Seasonal Property Protection - Ideal for vacation homes, cabins, and seasonal properties with generator systems
  • Industrial Cold Weather Applications - Essential for industrial facilities requiring reliable backup power in cold environments
  • Agricultural Operations - Critical for farm and agricultural facilities with generator systems in cold climates
  • Construction Site Winter Power - Necessary for construction generators operating through winter months

Cold Weather Protection Advantage

Generac's air cooled oil heater provides essential protection against cold weather starting problems and oil thickening that can prevent reliable generator operation. The direct oil filter mounting design ensures efficient heat transfer while the CSA certified construction guarantees safe operation. This professional accessory extends generator reliability into freezing temperatures, ensuring backup power availability when needed most during winter emergencies and cold weather power outages.

Why Choose Generac Quality?

Generac's commitment to reliable power generation extends to comprehensive cold weather protection accessories designed specifically for their generator systems. Advanced engineering ensures proper compatibility with 2008-present generator models while CSA certification provides safety assurance. Comprehensive testing and quality control deliver trusted backup power solutions for homes and businesses, with innovative cold weather features for ease of use and America's #1 selling generator brand reputation for dependable performance in all weather conditions.

Manufacturer Resources

Product Specs

Assembled Weight:
6.0 lbs
Carb Compliant:
Yes
Color Finish:
Orange
Country Of Origin:
United States
Engine Displacement:
0.0 cc
Frame Material:
Rubber
Fuel Type:
Natural Gas
Horsepower:
0.0 hp
Low Oil Shut Down:
No
Manufacturer Warranty:
1 Year
Portable Generator Starting Type:
Electric
Rated Wattage:
0
Restrictions:
No
Surged Wattage:
0
Voltage Rating:
0
Warranty Type:
Limited - Parts
Wheel Kit Included:
No
Department:
Electrical
Product Group:
Accessories
Product Subgroup:
Heater Kit
Product Length:
10.0 in
Product Height:
3.0 in
Product Weight:
2.0 lbs
Product Width:
6.0 in

Generac 7102 – Frequently Asked Questions

1) Will the Generac 7102 oil heater fit my air cooled standby generator?
The Generac 7102 oil heater fits Generac air cooled units manufactured from 2008 to present only. On older pre-2008 units it is not a compatible accessory. Check the manufacture date on the generator's data decal before ordering.
2) How does the Generac oil heater mount, and do I need to modify the generator?
It slips directly under the oil filter, so there is no cutting or drilling. You position the heater at the existing oil filter location, secure the assembly, then make the electrical connections. The unit itself is small, 10 inches long by 6 wide by 3 high, so it sits in the enclosure without interfering with service access.
3) Do I have to change the generator oil when I install a cold weather kit?
Yes. Installing any cold weather accessory calls for replacing the existing oil with 5W-30 synthetic. Budget for an oil change at the same visit so the crew is not making a second trip.
4) At what outdoor temperature does a generator actually need an oil heater?
Generac recommends the oil warmer for sites that regularly drop below 32 degrees F. Cold oil thickens and resists cranking, which is the usual reason a standby unit fails to start in a winter outage. If your location only sees occasional light frost, it is optional; in a climate with sustained freezing weather it is the accessory that keeps the start reliable.
5) Is the Generac 7102 oil warmer safety certified for permanent outdoor generator installation?
It is CSA certified, and it is made in the United States. It is also CARB compliant. The housing uses a rubber frame for weather resistance and is finished in orange so it is easy to spot inside the enclosure during service.
6) What part number do I order for the Generac air cooled oil warmer?
Order Generac 7102. That is the model and manufacturer part number for the air cooled oil heater cold weather accessory. The shipped kit weighs 6 lbs assembled; the heater itself is 2 lbs.
7) Does the 7102 oil heater add any electrical load or output to the generator?
No. It is an accessory heater, not a power producing component: rated wattage, surge wattage and voltage rating are all listed at 0, and there is no engine displacement or horsepower associated with it. It draws from the generator's accessory circuit and is wired in during installation.
8) When should I install and test a generator oil heater for the winter?
Install and test it before the cold season starts, not during the first outage. The sequence is: confirm the unit is a 2008 or newer Generac air cooled model, mount the warmer under the oil filter, swap in 5W-30 synthetic, make the electrical connections, then run a test of heater operation ahead of freezing weather.
How fast can I get the Generac 7102 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Generac 7102 come with a warranty?
Absolutely. The Generac 7102 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Generac 7102?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Generac 7102 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.