ABB TLM-CCU 20-Circuit 200A Co...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$774.06

ABB TLM-CCU 20-Circuit 200A Convertible Load Center, 1 Phase

(No reviews yet) Write a Review

Model: TLM2020CCU

In Stock (leaves warehouse same day if ordered before 3pm ET)

$774.06
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

ABB TLM-CCU 20-Circuit 200A Convertible Load Center, 1 Phase

The ABB TLM-CCU Convertible Load Center is engineered for dependable electrical distribution in indoor commercial, industrial, and residential installations. Rated for 120/240V ac service at 200 A with a 65 kAIC interrupt rating, this 1 Phase, 3 Wire load center accepts either a main breaker or main lug feeder configuration, giving electrical contractors flexibility during rough-in and panel scheduling. This load center is available in 20" and 40" enclosure sizes to fit a range of circuit-count and panel-layout requirements. Built to UL standards, it is designed to deliver safe, code-compliant performance for panelboard and branch-circuit distribution applications.

Key Features

  • Available Sizes: Offered in 20" and 40" enclosure sizes to match job-specific circuit capacity needs.
  • Amperage Rating: 200 A main rating supports demanding branch-circuit and feeder loads in indoor panelboard installations.
  • Convertible Feeder Design: Number of Feeders is listed as Either, allowing the load center to be configured with a main breaker or main lug assembly to match job requirements.
  • Interrupt Rating: 65 kAIC interrupt rating helps protect the electrical system against fault-current conditions.
  • Wiring Configuration: 3 Wire configuration supports standard single-phase residential and light commercial distribution.
  • Phase: 1 Phase design for typical single-phase service entrances and subpanels.
  • Voltage Rating: 120/240V ac load regulation matches common single-phase utility service.
  • Enclosure: Indoor enclosure rating suited for interior electrical rooms, utility closets, and finished mechanical spaces.

Certifications & Compliance

  • UL Listed (Standard: UL)

Technical Specifications

  • Available Sizes: 20", 40"
  • Interrupt Rating: 65 kAIC
  • Standard: UL
  • Amperage Rating: 200 A
  • Phase: 1 Phase
  • Wiring Configuration: 3 Wire
  • Enclosure: Indoor
  • Load Regulation: 120/240V ac
  • Number Of Feeders: Either
  • Packaging: 1 EA

Typical Applications

  • Residential and Light Commercial Electrical Panels
  • Main Breaker or Main Lug Panelboard Installations
  • Branch-Circuit Distribution Systems
  • Indoor Electrical Rooms and Utility Closets
  • New Construction and Service Panel Upgrades

Why ABB?

ABB engineers the TLM-CCU convertible load center to UL standards with a 65 kAIC interrupt rating, giving electrical professionals a dependable, code-compliant solution for indoor panelboard installations across 20" and 40" enclosure sizes. The flexible either-feeder design, 3 Wire configuration, and 120/240V ac, 200 A rating make it a practical, trusted choice for demanding single-phase electrical distribution needs.

Product Specs

Product Type:
Load Center
Amperage Rating:
200A
Voltage Rating:
120/240V
Configuration:
Main Breaker or Main Lug
Listing:
UL Listed
Product Size:
20"
Product Size:
40"
Department:
Electrical
Product Group:
Power Distribution
Trade Size:
20" - 40"
Product Subgroup:
Panelboards & Load Centers

ABB TLM2020CCU – Frequently Asked Questions

1) Can the ABB TLM load center be set up as a main breaker panel or does it have to be main lugs?
Either. The ABB 20-circuit 200A convertible load center ships convertible, so it can be configured with a main breaker assembly or as a main lug feeder panel. That is what makes it usable both as a service entrance panel and as a downstream subpanel without stocking two different enclosures. The main breaker or main lug kit is a separate item you specify to match the job.
2) Can I mount this ABB load center outside on the side of a building?
No. The ABB TLM convertible load center is an indoor enclosure only, meant for electrical rooms, utility closets, and finished mechanical spaces. For an exterior service entrance or any wet location you need a rainproof enclosure instead. Installing an indoor-rated panel outdoors will fail inspection.
3) Will a 200A 1 phase 3 wire load center work on my 3 phase service?
No. The ABB TLM is a 1 phase, 3 wire panel rated 120/240V ac, which is standard single phase service with two hots and a neutral. If your service is 3 phase, 208Y/120 or 480Y/277, you need a three phase panelboard, not this load center.
4) What is the closest Square D equivalent to the ABB TLM2020CCU convertible load center?
The nearest peer is the Square D QO convertible main lugs load center, a NEMA 1 panel from the QO series that, like the ABB TLM series, ships convertible so it can be set up for main lug or main breaker service. The ABB unit is rated 200A at 120/240V AC, single phase, three wire, UL Listed, in an indoor enclosure. The QO peer differs in that it uses a plug-on neutral bus, which changes how QO plug-on neutral breakers land on the interior; ABB TLM panels take ABB/Thomas & Betts style branch breakers instead, so breaker stock is not shared between the two.
5) I need more than 20 circuits in one panel. What should I use instead of the ABB 200A convertible load center?
Step up to the Square D Homeline 60-space, 120-circuit 225A convertible main lugs load center in a NEMA 1 enclosure. It carries a higher 225A main rating and far more spaces than the 20-circuit ABB TLM panel, which is rated 200A at 120/240V AC. Both are convertible designs, so either can be fed through main lugs or fitted with a main breaker. Confirm your service size and available wall width before ordering the larger Homeline can.
6) Is 65 kAIC enough for a service with a high available fault current?
The ABB TLM convertible load center carries a 65 kAIC interrupt rating, which is well above the 10 kAIC and 22 kAIC ratings common on residential-grade load centers. That matters on services close to a large utility transformer, where the available fault current at the panel can exceed a standard panel's rating. Confirm the utility's available fault current at your service point against the 65 kAIC figure, and remember the branch breakers installed in it carry their own AIC ratings.
7) How many breakers does the ABB 20-circuit load center hold?
Twenty circuits. That's the count for both the 20 inch and 40 inch enclosure versions of this 200A ABB convertible load center, so stepping up to the taller box buys gutter and wiring room rather than more spaces. If you need substantially higher circuit density, look at something like the Square D Homeline 60-space, 120-circuit 225A convertible main lugs load center instead.
8) What else could I use instead of the ABB TLM if I want a plug-on neutral panel?
The Square D QO convertible main lugs load center is a plug-on neutral, NEMA 1 panel, which lets combination AFCI and GFCI breakers snap onto the neutral bar instead of running a pigtail to a neutral lug. The ABB TLM is a conventional convertible load center. If your job is heavy on AFCI/GFCI branch circuits, the plug-on neutral design cuts wiring time in the gutter noticeably.
9) Can I use this ABB panel as a subpanel fed from an existing main?
Yes, that's the main lug configuration. Set up as main lugs, the ABB TLM takes a feeder from an upstream overcurrent device and distributes branch circuits, which is the normal subpanel arrangement. Used that way you bond nothing at the panel: the neutral and ground bars stay separate and the equipment ground runs back to the service. As a main breaker panel at the service entrance, the bonding is made at the panel.
10) Does the ABB 200A load center come with breakers or a main breaker?
Packaging is 1 EA, the load center enclosure and interior itself. The main breaker or main lug assembly is chosen to suit the feeder configuration, and branch breakers are ordered separately. Price the panel, the main device, and the branch breakers as three line items when you're bidding the job.
11) Is the Square D Homeline 225A panel a drop-in replacement for an ABB TLM4020CCU?
No. The Homeline 60-space 120-circuit 225A convertible main lugs load center is a much larger enclosure with a higher amperage rating than the ABB TLM4020CCU, which is a 20-circuit 200A panel rated 120/240V AC for indoor use. The can size, gutter space, and feeder conductor sizing all differ, and Homeline branch breakers are not interchangeable with ABB TLM breakers. Treat it as a capacity upgrade requiring new rough-in, not a swap.
How fast can I get the ABB TLM2020CCU delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the ABB TLM2020CCU come with a warranty?
Absolutely. The ABB TLM2020CCU is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the ABB TLM2020CCU?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the ABB TLM2020CCU from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.