ACSI M1510M-1-8205-LW1-R Sarge...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$1,188.00
$1,103.71

ACSI M1510M-1-8205-LW1-R Sargent 8200 Series Office, Entry Mortise Lever Lock Fail Safe LW1 Escutcheon Design, Reversible

(No reviews yet) Write a Review

Model: ACSI-M1510M-1-8205-LW1B-26D-LC
From the 1500 Series Collection
$1,188.00
$1,103.71
Selected Finish is

In Stock (leaves warehouse same day if ordered before 3pm ET)

$1,188.00
$1,103.71
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

ACSI M1510M-1-8205-LW1-R SARGENT 8200 SERIES OFFICE, ENTRY MORTISE LEVER LOCK FAIL SAFE OVERVIEW

M1510M-1-8205-LW1-R Sargent 8200 Series Office, Entry Mortise Lever Lock Fail Safe LW1 Escutcheon Design, Reversible. Sargent 8200 Series Office or Entry Mortise Lever Lock Modified with Fail Safe Operation (Power Lock), Standard Control Locks Outside (Secure Side) Trim, Motor Controlled, Less Cylinder.

ACSI Series 1500 Electric Mortise Locks provide safety and security for stairtower doors or controlled areas where both locking and latching are required. The locks are available in motor-controlled or solenoid-controlled to allow remote electric locking or unlocking while conforming to life-safety codes.

Buy the ACSI M1510M-1-8205-LW1-R Sargent 8200 Series Office, Entry Mortise Lever Lock Fail Safe LW1 Escutcheon Design, Reversible for easy installation and dependable door hardware solution.

ACSI M1510M-1-8205-LW1-R SARGENT 8200 SERIES OFFICE, ENTRY MORTISE LEVER LOCK FAIL SAFE PRODUCT FEATURES

  • Function: 1510M-Fail Safe Control
  • Product Type: Lock Part/Accessory
  • ADA Compliant: No
  • Standards: UL Listed; California State Fire Marshall Approved; Continuous Duty Rated
  • Function Family: Part/Component
  • Features: Motor Controlled; Low Power Consumption; Unlocks Outside Lockset in the Event of a Power Failure
  • For Use With: Sargent 8200 Series Office or Entry Mortise Lock
  • Manufacturer Parent: ACSI

ACSI-M1510M-1-8205-LW1-R ELECTRIFIED MORTISE LOCKS AVAILABLE CONFIGURATION

ACSI M1510M-1-8205-LW1-R Sargent 8200 Series Office, Entry Mortise Lever Lock Fail Safe LW1 Escutcheon Design, Reversible
ACSI M1510M-1-8205-LW1B-26D-LC Sargent 8200 Series Mortise Lock Fail Safe LW1 Escutcheon Design, B Lever Design
ACSI M1510M-1-8205-LW1F-26D-LC Sargent 8200 Series Mortise Lock Fail Safe LW1 Escutcheon Design, F Lever Design
ACSI M1510M-1-8205-LW1J-26D-LC Sargent 8200 Series Mortise Lock Fail Safe LW1 Escutcheon Design, J Lever Design
ACSI M1510M-1-8205-LW1L-26D-LC Sargent 8200 Series Mortise Lock Fail Safe LW1 Escutcheon Design, L Lever Design
ACSI M1510M-1-8205-LW1P-26D-LC Sargent 8200 Series Mortise Lock Fail Safe LW1 Escutcheon Design, P Lever Design

Product Specs

Series:
1500 Series
Collection:
1500 Series
Product Type:
Electronic Mortise Locks
ADA Compliant:
Yes
Features:
Simple User Selectable Fail Safe/Fail Secure Operation in Motor Controlled Locks, Continuous Duty Rated, Low Power Consumption, Interface With Life Safety Systems
Subcategory:
Electrified Mortise Locks
ANSI/BHMA:
UL Listed, California State Fire Marshall Approved, ANSI/BHMA A156.13 Series 1000 Operational Grade 1 and Security Grade 1 with All Standard Trims, UL and cUL Listed, ANSI/UL 10C, Positive Pressure Fire Test of Door Assemblies
Commercial/Residential:
Commercial
Electronic:
Yes
Lock Type:
Mortise
Handle Type:
Lever
Fail-safe / Fail-secure:
Field Selectable
Product Group:
Mechanical Locks
Product Subgroup:
Mortise Locks and Trim
Product Function:
Fail Safe
Electrical Configuration:
Latchbolt Monitor
Product Category:
Mechanical Locks
Department:
Door Hardware

ACSI ACSI-M1510M-1-8205-LW1B-26D-LC – Frequently Asked Questions

1) What exactly is the ACSI M1510M-1-8205 and does it replace a Sargent 8200 mortise lock or modify one?
It is a Sargent 8200 Series office/entry mortise lever lock that ACSI has factory-modified for electric control. You are buying the complete electrified lock, not a kit you add to a lock you already own. The modification is the motor-controlled 1510M fail safe function, built into the Sargent 8200 case with LW1 escutcheon trim.
2) On the ACSI 1510M fail safe mortise lock, what happens to the door when power drops?
Power failure unlocks the outside lockset. The lever on the secure side becomes free to retract the latch, so people can get in as well as out. That is why this function suits stairtower doors and controlled areas that have to release on a fire alarm or power loss. Locking is motor-controlled and the lock is continuous duty rated with low power draw, so it can sit energized all day.
3) Can this ACSI motor-controlled mortise lock be switched to fail secure in the field?
Yes. Fail safe versus fail secure is user selectable on the motor controlled locks, so the same lock can be set to unlock on power loss or to stay locked on power loss. That matters if you are standardizing hardware across a building where stair doors need fail safe and tenant suites need fail secure. Solenoid-controlled versions of the 1500 Series are fixed function, so specify the motor version when you want the choice.
4) Does the ACSI 1500 Series electrified mortise lock come with a cylinder?
No. It ships less cylinder on every configuration, so you supply the mortise cylinder and cam to match your keyway and master key system. For a locksmith that is usually the preferred way to buy it, since the cylinder gets keyed into the existing system rather than shipped in a random keyway.
5) Will this lock work on a fire-rated stair door and meet code for an institutional facility?
It carries UL and cUL Listing, California State Fire Marshal approval, and ANSI/UL 10C positive pressure fire test of door assemblies. It is rated ANSI/BHMA A156.13 Series 1000 Operational Grade 1 and Security Grade 1 with all standard trims, and the lock is ADA compliant. That combination is what a hospital, school, or government spec normally calls for on a stairtower opening.
6) Can the access control system see whether the door actually latched?
Yes. The lock is configured with a latchbolt monitor, so the head end gets a signal telling it the latchbolt is thrown rather than just that the lock was commanded to lock. On a stair or perimeter door that is the difference between knowing the opening is secure and assuming it. The 1500 Series is also built to interface with life safety systems for alarm release.
7) Which side does the electric control lock on this ACSI 1510M, the inside or the outside lever?
Control locks the outside, secure side trim. The inside lever always retracts the latch for free egress; only the outside lever is locked and unlocked electrically. That is the standard arrangement for stair re-entry and controlled entry openings.
8) Which lever designs and finish are available on the ACSI M1510M LW1 escutcheon mortise lock?
Five Sargent lever designs are offered on the LW1 escutcheon: B, F, J, L and P. All are supplied in 26D satin chrome. Pick the lever design that matches the mechanical 8200 locks already hanging on the other doors so the electrified opening does not look like an afterthought.
9) Is this ACSI electrified mortise lock handed, or will one part number work on either door swing?
The base M1510M-1-8205-LW1-R is reversible, so the same lock handles either swing and you do not have to commit to a hand at order time. Good news for a property manager stocking a spare: one unit covers whichever stair door fails first.
10) Should I use an electrified mortise lock like this or an electric strike on a controlled stair door?
Use the electrified mortise lock when the opening has to both lock and latch and you need to control the lever itself, which is the case on stairtower and controlled-area doors. An electric strike releases the frame side and leaves the lever locked, so it does not give you stair re-entry through the lever and it does not report latchbolt position the way this lock does with its latchbolt monitor. The lock also keeps the door's fire-rated latching intact, since it is UL 10C tested as part of the door assembly.
11) Is the ACSI 1500 Series lock suitable for residential use?
No, it is a commercial product. The 1500 Series electric mortise lock is built for continuous duty on commercial openings with access control wiring behind them, and it needs a power supply and a control system to do anything. For a house, a standard mechanical mortise or cylindrical lockset is the right call.
How fast can I get the ACSI ACSI-M1510M-1-8205-LW1B-26D-LC delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the ACSI ACSI-M1510M-1-8205-LW1B-26D-LC come with a warranty?
Absolutely. The ACSI ACSI-M1510M-1-8205-LW1B-26D-LC is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the ACSI ACSI-M1510M-1-8205-LW1B-26D-LC?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the ACSI ACSI-M1510M-1-8205-LW1B-26D-LC from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.