BEST 9KW Series Electrically L...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$1,482.00
$784.14

BEST 9KW Series Electrically Locked Function (Fail-Secure) Grade 1 Electromechanical Cylindrical Lever Locks

(No reviews yet) Write a Review

Model: 9KW37DEU14CSTK626
$1,482.00
$784.14
Selected Finish is
Selected Lever Style is
Selected Rose Style is
Selected Backset is
Selected Strike is

In Stock (leaves warehouse same day if ordered before 3pm ET)

$1,482.00
$784.14
Adding to cart… The item has been added
Free Shipping on orders over $99
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

BEST 9KW SERIES ELECTROMECHANICAL CYLINDRICAL LOCKS

Our wired mechanical locks provide a unique way to lock and unlock the door from a remote location for safety, security, or convenience.

The BEST 9KW electromechanical locks provide fail-safe (electrically locked) and fail-secure (electrically unlocked) operations through an individual switch, switch lock, relay, access control system or other automatic control system. More importantly, these locks exhibit the same features and meet the same standards and specifications as the BEST mechanical 40H mortise and 8K/9K heavy-duty cylindrical locksets.

FEATURES

  • Non-handed levers allow for ease of installation
  • Lock chassis meets the requirements as listed in the ANSI/BHMA A156.2, standard for Series 4000 Grade 1 locks
  • UL listed for GYQS Electrically controlled single point licks or latches for use on 3 hr, A label single doors (4' x 10') GYJB. The listing applies for both U.S. and Canadian applications
  • Request-to-exit sensor positioned inside lock trim
  • The ISC (Intelligent System Controller) is embedded behind the escutcheon secured and out of site
  • Request-to-exit and door contact sensors are standard in IDH MAX cylindrical locks

SPECIFICATIONS

Types

  • 12 volts AC/DC when used with supplied TCM — 0.50 amps
  • 24 volts AC/DC when used with supplied TCM — 0.18 amps
  • All EU functions: Electrically Unlocked (Fail Secure)
  • All EL functions: Electrically Locked (Fail Safe)

Approval Listings

  • UL listed for GYQS Electrically- controlled singlepoint locks or latches.
  • This product has been approved by the California State Fire Marshal (CSFM) pursuant to section 13144.1 of the California Health and Safety Code.
  • Approved by the city of New York Board of Standards and Appeals under calendar number 730-89-SA. See CSFM listing No. 4136-1175:103. It is subject to re-examination, revision and possible cancellation

Door thickness

  • Standard lock configuration designed for doors 1 3/4" – 2 1/4" thick. NOTE: All W-series locks require the use of a (TCM) Temperature Control Module. A TCM and TCM connector are supplied standard with every order.

RESOURCES & DOWNLOADS

W Series Sell Sheet
W&M Series Catalog
BEST Electronics Brochure
EAD & DHW Warranty Statement

Manufacturer Resources

Product Specs

Series:
9KW Series
Subcategory:
Bored Locksets
Grade:
Grade 1
Duty Level:
Heavy Duty
Handle Type:
Lever
Keyed Function:
Single Cylinder
Warranty:
10 Year Limited
Product Group:
Mechanical Locks
Product Subgroup:
Bored Locksets
Product Type:
Electromechanical Leversets
Keyed:
Yes
Electronic:
Yes
Commercial/Residential:
Commercial
Lock Type:
Cylindrical
Product Attribute:
Cylindrical Locks
Product Function:
Fail-Secure
Door Hand Direction:
Non-Handed
Product Category:
Mechanical Locks
Product Substrate:
Corrosion-Treated Steel

BEST 9KW37DEU14CSTK626 – Frequently Asked Questions

1) What is the difference between fail secure and fail safe operation?
Fail secure locks remain locked when power is lost. This provides maximum security but requires backup power systems for emergency egress. Fail safe locks unlock during power failure for life safety compliance.
2) What door types work with Grade 1 electromechanical cylindrical locks?
These locks fit standard commercial doors with 2-1/8" bore holes. Compatible with wood, metal, and composite doors. Verify door thickness falls within manufacturer specifications before installation.
3) How do I determine the correct handing for installation?
Stand on the outside of the door. If hinges are on the right, it's right-handed. If hinges are on the left, it's left-handed. Many electromechanical locks are field-reversible for either handing.
4) What voltage and power requirements do 9kW series locks need?
Most electromechanical locks operate on 12V or 24V DC power. Check manufacturer specifications for exact voltage and current draw requirements. Install appropriate power supplies and backup systems.
5) Do these locks meet ADA compliance requirements?
Grade 1 cylindrical locks typically meet ADA requirements when properly installed. Verify lever height, operating force, and accessible approach clearances comply with current accessibility standards.
6) What building codes apply to electrically locked doors?
Fire and life safety codes regulate electric locks. Most require instant unlock on fire alarm activation. Check local codes for egress requirements, backup power mandates, and inspection protocols.
7) What accessories are needed for complete installation?
Typical installations require power supplies, magnetic door position switches, request-to-exit devices, and emergency release hardware. Wire management accessories and backup battery systems may also be needed.
8) How do I integrate with access control systems?
Most electromechanical locks accept standard access control inputs. Connect card readers, keypads, or biometric devices according to manufacturer wiring diagrams. Verify voltage compatibility between components.
9) What maintenance do electromechanical locks require?
Regular maintenance includes cleaning contacts, lubricating moving parts, and testing emergency release functions. Check battery backup systems quarterly. Schedule professional inspections per manufacturer recommendations.
10) Can I retrofit existing cylindrical lock preparations?
Most electromechanical cylindrical locks fit standard 2-1/8" bore preparations. Additional drilling may be required for wire routing and mounting hardware. Verify existing door thickness and material compatibility.
11) How do extreme temperatures affect lock performance?
Electronic components have specified operating temperature ranges. Cold weather increases power consumption while heat affects component life. Install appropriate environmental protection for outdoor applications.
How fast can I get the BEST 9KW37DEU14CSTK626 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the BEST 9KW37DEU14CSTK626 come with a warranty?
Absolutely. The BEST 9KW37DEU14CSTK626 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the BEST 9KW37DEU14CSTK626?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the BEST 9KW37DEU14CSTK626 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.