Electrical

Eaton breakers, loadcenters, meter sockets and disconnects: which part fits the gear on your wall

Which Eaton breaker, loadcenter, meter socket or disconnect do I need?

  • Spa or well pump: Eaton BR Series GFCI Circuit Breaker, Two-Pole, 120/240V
  • Subpanel for BR breakers: Eaton Type BR Main Lug Loadcenter 125A 6/12 Circuit Single-Phase
  • Subpanel for CH breakers: Eaton Type CH Main Lug Loadcenter, Single-Phase 120/240V, Copper Bus
  • Fused motor disconnect: Eaton DH Heavy-Duty Fusible Safety Switch, Three-Pole, 600V
  • Tenant meter swaps: Eaton 200A Single-Phase Meter Socket with Lever Bypass and Barrel Lock
  • Warehouse or parking lot lighting: Eaton BAB Series Quicklag Thermal-Magnetic Circuit Breaker, Bolt-On
  • Main breaker for a 480V three-phase panelboard: Eaton Pow-R-Xpress Convertible Main Circuit Breaker Kit

Read the label inside the panel door first: the Eaton BR Series AFCI Circuit Breaker 15A/20A Single-Pole 120V 10kAIC Plug-On fits only a Type BR loadcenter, and the Eaton CH Series Two-Pole Thermal Magnetic Circuit Breaker 240V 10kAIC Common Trip only a Type CH loadcenter.

On this page

Will an Eaton BR AFCI breaker fit my existing panel?

Eaton BR Series AFCI Circuit Breaker 15A/20A Single-Pole 120V 10kAIC Plug-On

The Eaton BR Series AFCI Circuit Breaker 15A/20A Single-Pole 120V 10kAIC Plug-On fits only a Type BR loadcenter, because its plug-on footprint is BR specific.

  • Check the label inside the panel door for Type BR before ordering.
  • It gives arc fault (AFCI) protection only, for bedroom, living area and general lighting circuits.
  • The pigtail version, with a white neutral wire for the neutral bar, fits any Type BR loadcenter, old or new.
Eaton BR Series AFCI Circuit Breaker 15A/20A Single-Pole 120V 10kAIC Plug-On
Feature Option Plug-on Neutral, Pigtail
Choose Amperage Rating 15A, 20A

Should I put a 15A or a 20A Eaton BR AFCI breaker on this circuit?

Match the Eaton BR Series AFCI Circuit Breaker 15A/20A Single-Pole 120V 10kAIC Plug-On to the wire in the wall: #14 conductor takes the 15A, #12 conductor takes the 20A.

  • A 20A breaker on #14 wire is the classic mistake, and it defeats the overcurrent protection.
  • The breaker lug takes #14 through #8 AWG, copper or aluminum.

Does the Eaton BR AFCI breaker also give me GFCI protection for a kitchen or bath circuit?

No, the Eaton BR Series AFCI Circuit Breaker 15A/20A Single-Pole 120V 10kAIC Plug-On is arc fault only, so a kitchen counter or bath circuit takes the Eaton GFCI Circuit Breaker Single-Pole 120V 10kAIC Plug-On Ground Fault Protection.

  • The single-pole GFCI breaker gives ground fault protection at 5 mA, the sensitivity used where people and water meet.
  • Bedroom, living area and general lighting circuits that only call for arc fault are what the AFCI breaker is for.

Will the Eaton single-pole GFCI breaker fit my existing panel?

Eaton GFCI Circuit Breaker Single-Pole 120V 10kAIC Plug-On Ground Fault Protection

It fits a load center that takes Eaton BR-style plug-on breakers, because the Eaton GFCI Circuit Breaker Single-Pole 120V 10kAIC Plug-On Ground Fault Protection seats directly onto the panel bus.

  • It is not a bolt-on breaker and will not mount in a panel that needs bolt-on attachment.
  • A single-pole unit takes one 1-inch space, with a body depth of 4 inches.
  • When it trips on a ground fault, the handle goes to center and the GFI indicator shows.

Can the Eaton single-pole GFCI breaker be used on a 240V circuit?

No, the Eaton GFCI Circuit Breaker Single-Pole 120V 10kAIC Plug-On Ground Fault Protection wires as one hot and a neutral, so a 240V load takes the Eaton BR Series GFCI Circuit Breaker, Two-Pole, 120/240V.

  • The two-pole GFCI comes in 30A and 60A, and the 30A covers a well pump or a spa feeder.
  • Its common trip opens both poles together during a fault.
  • The 50A and 60A single-pole GFCI parts are still 120V, so do not use them as a two-pole substitute.
Eaton BR Series GFCI Circuit Breaker, Two-Pole, 120/240V
Amperage Option 30A, 60A

Can I swap a standard two-pole BR breaker for the Eaton BR two-pole GFCI breaker in an existing panel?

Eaton BR Series GFCI Circuit Breaker, Two-Pole, 120/240V

Yes, the Eaton BR Series GFCI Circuit Breaker, Two-Pole, 120/240V lands in the same BR two-pole position, and the difference at install is the wiring.

  • The circuit neutral lands on the breaker and the coiled white pigtail goes on the panel neutral bar.
  • A circuit that shares a neutral with another circuit has to be separated first.
  • Lugs take #14-4 AWG, so existing conductors in that range reland directly.

Will the Eaton BR 70A two-pole breaker fit my Eaton BR load center?

Eaton Type BR 70A 2-Pole Plug-On Circuit Breaker 120/240V with 10 kAIC Interrupt Rating

Yes, if it is a Type BR panel: the Eaton Type BR 70A 2-Pole Plug-On Circuit Breaker 120/240V with 10 kAIC Interrupt Rating snaps onto the bus with no mounting hardware.

Replacing an Eaton CH two-pole breaker, do I need to match the amperage exactly?

Eaton CH Series Two-Pole Thermal Magnetic Circuit Breaker 240V 10kAIC Common Trip

Match it to the circuit's wire size and load, not just the old breaker, then order the Eaton CH Series Two-Pole Thermal Magnetic Circuit Breaker 240V 10kAIC Common Trip for a Type CH loadcenter.

  • A previous breaker may have been oversized, so check the wire before matching it.
  • Each two-pole unit takes two adjacent 3/4-inch spaces in the loadcenter.
  • Eaton lists it for main breaker duty in Type CH loadcenters, sized to the loadcenter's bus rating.
Eaton CH Series Two-Pole Thermal Magnetic Circuit Breaker 240V 10kAIC Common Trip
Amperage Option 60A, 70A, 80A, 90A, 100A, 125A

Is the Eaton CH three-pole breaker right for a three-phase rooftop unit in a small retail space?

Eaton CH Series Three-Pole Thermal Magnetic Circuit Breaker 240V 10kAIC Common Trip

Yes, for 240V or 208V three-phase equipment fed from a Type CH loadcenter, the Eaton CH Series Three-Pole Thermal Magnetic Circuit Breaker 240V 10kAIC Common Trip is the breaker.

  • Match the amperage to the nameplate on the rooftop unit, and take three adjacent spaces.
  • Where the nameplate calls for HACR-rated (heating and air conditioning) or fuse-only protection, follow the nameplate.
  • A fault on any one pole opens all three, so a motor is not left single-phasing.
Eaton CH Series Three-Pole Thermal Magnetic Circuit Breaker 240V 10kAIC Common Trip
Choose Amperage Rating 15A, 25A, 30A, 40A, 60A, 70A

Will an Eaton CL two-pole breaker fit a Square D Homeline panel?

Eaton CL Series 2-Pole Circuit Breaker 120/240V 10 kAIC Classified Replacement System

Yes, the Eaton CL Series 2-Pole Circuit Breaker 120/240V 10 kAIC Classified Replacement System is listed for Square D Homeline, GE Type THQ, Crouse-Hinds Type MP and Thomas and Betts Type TB panels, as well as Type CH loadcenters.

  • Confirm the panel label allows classified breakers, since some labels restrict replacements to their own brand.
  • On a property mixing CH and Homeline panels, one CL part number can cover both.
  • Lugs take #14 through #4 AWG, copper or aluminum, across the whole amperage range.
Eaton CL Series 2-Pole Circuit Breaker 120/240V 10 kAIC Classified Replacement System
Amperage Option 15A, 20A, 25A, 30A, 35A, 40A and 2 more
Security Feature Standard

Can I use an Eaton CHF breaker on an air conditioner or heat pump circuit?

Eaton CHF Series 2-Pole Plug-On Circuit Breaker 120/240V 10 kAIC with Switching Neutral

Yes, the Eaton CHF Series 2-Pole Plug-On Circuit Breaker 120/240V 10 kAIC with Switching Neutral is HACR rated, the qualification for heating, air conditioning and refrigeration equipment circuits.

  • Size it to the maximum overcurrent protection on the equipment nameplate, not to the wire alone.
  • It plugs onto Type CH loadcenters only, and is not interchangeable with BR breakers.
Eaton CHF Series 2-Pole Plug-On Circuit Breaker 120/240V 10 kAIC with Switching Neutral
Amperage Option 15A, 20A, 25A, 30A, 35A, 40A and 2 more
Security Feature Standard

What does an Eaton CHT twin half-slot breaker actually do for panel space?

Eaton CHT Series Twin Single-Pole Plug-On Circuit Breaker 120/240V 10k

The Eaton CHT Series Twin Single-Pole Plug-On Circuit Breaker 120/240V 10k puts two independent single-pole circuits into one full-size space, so you can add a circuit to a full panel.

Eaton CHT Series Twin Single-Pole Plug-On Circuit Breaker 120/240V 10k
Security Feature Standard
Amperage 15A, 20A
Amperage Option 15-20A, 15-15A, Standard

Will an Eaton QBHW breaker fit my existing panel, or do I need a specific type of panelboard?

Eaton QBHW Thermal Magnetic Circuit Breaker 22kAIC with 120-240V Shunt Trip

It needs a panel whose breakers screw in, because the Eaton QBHW Thermal Magnetic Circuit Breaker 22kAIC with 120-240V Shunt Trip fastens with screws instead of clipping on.

  • A panel built for plug-on breakers that snap over a stab will not seat it.
  • Bolt-on is standard on commercial and industrial panelboards, which is where this breaker belongs.
  • It is rated 22 kAIC, the fault current it can interrupt: check that against your panel's fault current.
Eaton QBHW Thermal Magnetic Circuit Breaker 22kAIC with 120-240V Shunt Trip
Pole Option 1P, 2P, 3P
Security Feature Standard
Voltage 120/240V, 240V
Choose Amperage Rating 15A, 20A, 25A, 30A, 35A, 40A and 6 more

Which Eaton BAB breaker should I use on a parking lot or warehouse lighting circuit?

Eaton BAB Series Quicklag Thermal-Magnetic Circuit Breaker, Bolt-On

Use the HID rated version of the Eaton BAB Series Quicklag Thermal-Magnetic Circuit Breaker, Bolt-On, built to ride through the long startup inrush of high intensity discharge lighting.

  • A standard breaker sized to the running load will nuisance-trip on that inrush.
  • It is bolt-on, so the panelboard has to take bolt-on breakers rather than plug-on ones.
  • It interrupts 10 kAIC, or 10,000 amperes, so check that against the fault current at your panel.
Eaton BAB Series Quicklag Thermal-Magnetic Circuit Breaker, Bolt-On
Security Feature Shunt-Trip (Low Voltage), HID Rated
Voltage 120/240V
Amperage Option 10A
Pole Option 1P, 2P

How do I order the right Eaton Quicklag QC breaker to replace a failed one in a Quicklag panelboard?

Eaton Quicklag QC Single-Pole Thermal-Magnetic Circuit Breaker, 120/240V

Match the amperage of the breaker coming out and order the same rating of the Eaton Quicklag QC Single-Pole Thermal-Magnetic Circuit Breaker, 120/240V.

  • With cable-in/cable-out terminations, a same-family replacement drops back into the same position and lands on the same conductors.
  • Cable-in/cable-out means line and load land on lugs on the breaker, not on a bus stab.
  • Do not step the amperage up to stop nuisance tripping, since the breaker is sized to the wire.
Eaton Quicklag QC Single-Pole Thermal-Magnetic Circuit Breaker, 120/240V
Amperage Option 10 amperes, 15 amperes, 20 amperes, 30 amperes, 40 amperes

What is the difference between an Eaton main breaker kit and just buying a main breaker?

Eaton Main Breaker Kit Pow-R-Stock Series ED Single/Three Phase Top/Bottom Mount

The Eaton Main Breaker Kit Pow-R-Stock Series ED Single/Three Phase Top/Bottom Mount is the ED-frame breaker plus the mounting hardware that converts a main lug panel into a main breaker panel.

  • A main lug panel has no main breaker: the feeder lands on lugs and protection sits upstream.
  • A loose ED breaker alone comes without the mounting hardware to fit it in the panel.
  • The kit mounts at the top or bottom of the panel, useful when the service feed enters from below.

Is 35 kAIC enough, or do I need the 65 kAIC version of the Eaton Pow-R-Xpress main breaker kit?

Eaton Pow-R-Xpress Convertible Main Circuit Breaker Kit

The available fault current at the panel decides it: if more than 35 kA reaches the panelboard, the Eaton Pow-R-Xpress Convertible Main Circuit Breaker Kit needs the 65 kAIC version.

  • Take the number from the fault current study for that panel location.
  • It is UL 67 Listed, the panelboard standard, which covers healthcare and school power systems.
Eaton Pow-R-Xpress Convertible Main Circuit Breaker Kit
Wire range Al/Cu (1) #4-4/0, (1) 250-500 kcmil, (2) 3/0-250 kcmil or (1) 3/0-500 kcmil, (2) #2-500 kcmil, (1) #14-1/0
Amperage Option 125A, 200A
Max. Voltage 240, 480
kAIC rating 35A, 65A
Configuration Option Standard

Will the Eaton main lug connector kit fit my Pow-R-Xpress panelboard?

Eaton Panelboard Main Lug Connector Kit 600A 1-Phase/3-Phase Pow-R-Xpress System

It fits Pow-R-Xpress PRL1X/2X and PRL1A/2A panelboards: the Eaton Panelboard Main Lug Connector Kit 600A 1-Phase/3-Phase Pow-R-Xpress System is the main lug assembly for those four designations.

  • Match the kit to the panelboard's main rating, not to the feeder breaker size upstream.
  • It ships as a separate assembly you mount into the panelboard interior in the field.
  • The same part number covers single-phase and three-phase panelboards in that range.
Eaton Panelboard Main Lug Connector Kit 600A 1-Phase/3-Phase Pow-R-Xpress System
Choose Amperage Rating 100A, 225A, 400A, 600A

Can the Eaton Type BR 125A main lug loadcenter be mounted outside?

Eaton Type BR Main Lug Loadcenter 125A 6/12 Circuit Single-Phase

Yes, if you order the outdoor enclosure of the Eaton Type BR Main Lug Loadcenter 125A 6/12 Circuit Single-Phase, with the same bus, rating and BR breaker fit as the indoor enclosure.

  • Ordering the indoor enclosure for a wall exposed to weather is the mistake to avoid on this panel.
  • It has no main breaker inside, so it has to be fed from a breaker upstream sized for the feeder.
  • It is built for 120/240V single-phase three-wire service, not a three-phase system.
Eaton Type BR Main Lug Loadcenter 125A 6/12 Circuit Single-Phase
Number os Spaces 6, 8
Trim Type Surface/Flush (RP/SP/FGP/FDGP)
Maximum Circuits 12, 16
Enclosure Option Indoor, Outdoor
Configuration Type Standard

Can I keep one breaker stock across an apartment portfolio of Eaton CH main lug loadcenters?

Eaton Type CH Main Lug Loadcenter, Single-Phase 120/240V, Copper Bus

Yes, every configuration of the Eaton Type CH Main Lug Loadcenter, Single-Phase 120/240V, Copper Bus, indoor or outdoor, uses the same CH breakers.

  • A tech pulling a 20A single pole does not need to know which building they are in.
  • Outdoor boxes carry a box size code ending in R, and indoor codes drop the R.
  • It is rated 25 kAIC, which covers most residential and light commercial services.
Eaton Type CH Main Lug Loadcenter, Single-Phase 120/240V, Copper Bus
Box Size Option X2R, X1, X0, X2, X0R, X5 and 1 more
Amperage Option 125A, 150A, 225A
Number Of Spaces Option 12, 16, 20, 24, 32, 42
Number of Poles Available 24, 32, 40, 48, 64, 84
EnclosureType Outdoor, Indoor
Wire Size Range Cu/Al 60C or 75C #6-2/0, #4-300 kcmil

Can an Eaton three-phase BR loadcenter be used as service entrance equipment?

Eaton Type BR Three-Phase Main Circuit Breaker Loadcenter

Yes, the Eaton Type BR Three-Phase Main Circuit Breaker Loadcenter is listed for service entrance use and ships with the neutral bonding strap already attached.

  • It is a three-phase, four-wire panel rated 208Y/120V and 240V, not for single-phase 120/240V service.
  • It takes Eaton Type BR 1-inch breakers.
  • It has no feed-thru lugs, so feed a downstream panel from a branch breaker instead.
Eaton Type BR Three-Phase Main Circuit Breaker Loadcenter
Maximum Circuits 42
Main Ampere Rating 200A
Enclosure Option Outdoor, Indoor
Main Breaker Type CC 10 kAIC
Bus Material Copper Bus

Can the Eaton CH loadcenter be mounted outdoors on the side of a house?

Eaton CH Loadcenter, NEMA 3R Main Breaker Panel, Copper Bus

Yes, the Eaton CH Loadcenter, NEMA 3R Main Breaker Panel, Copper Bus comes in a NEMA 3R metallic enclosure rated for outdoor and wet-location use against rain and sleet.

  • It is built for overhead-feed service entrances, so the feeder enters from the top.
  • An integrated main breaker gives the service disconnect and overcurrent protection in the same enclosure.
  • It is rated 120/240V single-phase, with the cover included.
Eaton CH Loadcenter, NEMA 3R Main Breaker Panel, Copper Bus
Amperage Option 200

Does the Eaton CH surface-mount loadcenter cover work on a recessed panel as well as a surface-mounted one?

Eaton CH Surface-Mount Loadcenter Cover, NEMA 1, Sandalwood

Yes, the Eaton CH Surface-Mount Loadcenter Cover, NEMA 1, Sandalwood is a surface or flush universal front, so one part number covers both mounting conditions.

  • On a multi-family turn, you stock one cover per space count rather than two.
  • It is the cover only, and the loadcenter box and bus are not included.
  • It is rated for indoor dry locations only, with no gasketing against rain.
Eaton CH Surface-Mount Loadcenter Cover, NEMA 1, Sandalwood
Type of Connection Main Lug, Main Breaker
Maximum Number 3/4-Inch (19.1 mm) of Poles 64, 84, 120
Maximum Number 3/4-Inch (19.1 mm) of Spaces 32, 42, 60
Choose Amperage Rating 100A, 225A

Do I need to buy fuses for the Eaton 60A air conditioning pullout disconnect?

Eaton Air Conditioning Disconnect Non-Fusible Pullout Device 60A Outdoor Safety Switch

No fuses are needed: the Eaton Air Conditioning Disconnect Non-Fusible Pullout Device 60A Outdoor Safety Switch breaks the circuit when the pullout block comes out, and overcurrent protection comes from the panel breaker upstream.

  • If the condenser nameplate gives a maximum fuse size, use the Eaton DH Heavy-Duty Fusible Safety Switch, Three-Pole, 600V instead.
  • It is built for outdoor installation alongside condensing units and heat pumps.
  • Size from the nameplate, not tonnage: above 60A, use the non-fusible Eaton DH Heavy-Duty Safety Switch 100A Professional Power Disconnect.
Eaton Air Conditioning Disconnect Non-Fusible Pullout Device 60A Outdoor Safety Switch
Choose Amperage Rating 60A

Will the Eaton NEMA 3R galvanized AC disconnect work for my outdoor condensing unit?

Eaton Air Conditioning Disconnect Switch Non-Fused Pullout NEMA 3R Galvanized Steel 120/240V

Yes, the Eaton Air Conditioning Disconnect Switch Non-Fused Pullout NEMA 3R Galvanized Steel 120/240V has a NEMA 3R galvanized steel enclosure rated for rain, sleet and ice on an outdoor wall or condenser pad.

Eaton Air Conditioning Disconnect Switch Non-Fused Pullout NEMA 3R Galvanized Steel 120/240V
Choose Amperage Rating 30A, 60A

Does the Eaton DH heavy-duty fusible three-pole switch come with fuses installed?

Eaton DH Heavy-Duty Fusible Safety Switch, Three-Pole, 600V

No, the Eaton DH Heavy-Duty Fusible Safety Switch, Three-Pole, 600V has the Class H fuse clips, and the fuses are sized and bought separately to match the load.

  • Class H is the standard non-current-limiting fuse clip arrangement, so Class H and Class K fuses drop in.
  • Lugs take #14 through #2 AWG, copper or aluminum, on a 3-wire configuration.
  • It serves as service entrance equipment once a neutral or ground lug kit is installed.
Eaton DH Heavy-Duty Fusible Safety Switch, Three-Pole, 600V
Enclosure / NEMA Rating NEMA 12/3R Painted Galvanized
Amperage Option 30 amperes, 100 amperes

Should I order a fusible or non-fusible Eaton DH safety switch?

Eaton DH Heavy-Duty Safety Switch 100A Professional Power Disconnect

Order the Eaton DH Heavy-Duty Safety Switch 100A Professional Power Disconnect in its fusible build when the switch has to carry the overcurrent protection itself, and its non-fusible build when a breaker upstream already protects the circuit.

  • Fusible is typical at a service disconnect or a motor branch circuit that needs its own fuses.
  • Non-fusible suits a local disconnect within sight of an AC unit or rooftop motor.
  • Fusible with neutral is for a circuit carrying a neutral you need to land and isolate.
Eaton DH Heavy-Duty Safety Switch 100A Professional Power Disconnect
Configuration Option 4-Wire (Three Blades, 3-Fuses, S/N) 480 Vac 600 Vac, 250 Vdc, 3P, 4-Wire (Three Blades, Three Fuses, S/N) 240 Vac, 250 Vdc, Standard, 3-Wire (Two Blades, Two Fuses, S/N) 240 Vac, 250 Vdc
Choose Amperage Rating 30A, 60A, 100A, 200A, 400A, 600A and 1 more
Fused Type Standard, Fusible with Neutral, Non-Fusible, Fusible
NEMA Option NEMA 1, NEMA 3R, NEMA 12, Standard

What does the lever bypass on the Eaton 200A Single-Phase Meter Socket let an electrician do?

Eaton 200A Single-Phase Meter Socket with Lever Bypass and Barrel Lock

The lever bypass on the Eaton 200A Single-Phase Meter Socket with Lever Bypass and Barrel Lock shunts current around the jaws, so the meter can be pulled and reset without dropping power to the load.

  • For occupied units or a retail tenant, meter swaps and testing happen without a service outage.
  • It is a single-position socket, so it meters one service only.
  • Line and load terminals take #6 through 350 kcmil, rated 200A at 600V.
Eaton 200A Single-Phase Meter Socket with Lever Bypass and Barrel Lock
Amperage Option 200A

Can I use the Eaton 200A ringless meter socket for an overhead drop, or only underground?

Eaton 200A Single-Position Ringless Meter Socket, Over/Under Feed

Either works: the Eaton 200A Single-Position Ringless Meter Socket, Over/Under Feed takes service from the top for an overhead drop or from the bottom for an underground lateral.

  • Ringless means the cover locks over the meter without a separate sealing ring.
  • Ringless and ring-type are not interchangeable, so order the style your serving utility specifies.
  • It is UL Listed and carries a Central Maine Power utility approval.
Eaton 200A Single-Position Ringless Meter Socket, Over/Under Feed
Model UTRS213CE

How many tenants will the Eaton 5-socket aluminum bus meter pack serve, and at what amperage each?

Eaton Aluminum Bus Meter Pack, NEMA 3R, 5-Socket

The Eaton Aluminum Bus Meter Pack, NEMA 3R, 5-Socket serves five tenants, with each socket rated 125A at 120/240V, single-phase in and single-phase out.

  • It suits a five-unit apartment building or a small strip of light commercial suites.
  • It has no bypass, so a meter pull drops that tenant's service.
  • The tenant breakers are ordered separately, so put them on the same order.
Eaton Aluminum Bus Meter Pack, NEMA 3R, 5-Socket
Model 1MP5206R

What is an Eaton multiple metering meter stack used for in an apartment building?

Eaton Multiple Metering Residential Meter Stack, Copper Bus, No Bypass

The Eaton Multiple Metering Residential Meter Stack, Copper Bus, No Bypass is the centralized metering assembly that lets each tenant be metered and billed individually off one service.

  • It stacks multiple meter positions in one vertical enclosure, so a meter room serves several units from one lineup.
  • It measures 7.01 inches wide and 12.26 inches deep, and stands 48.5 inches tall.
  • Power to a position drops when the utility removes the meter, so check your utility's bypass rules.
Eaton Multiple Metering Residential Meter Stack, Copper Bus, No Bypass
Configuration Option BC, AB

Shop the full line of Eaton breakers, loadcenters, meter sockets and disconnects at ZenSupply.

Need help speccing a job?
Our team answers spec and compatibility questions.
Contact our spec team