Bussmann LIMITRON KTS-R Series...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$126.53

Bussmann LIMITRON KTS-R Series Class RK1 Fast-Acting Fuse

(No reviews yet) Write a Review

Model: KTS-R-15

In Stock (leaves warehouse same day if ordered before 3pm ET)

$126.53
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Bussmann LIMITRON KTS-R Series Class RK1 Fast-Acting Fuse

The Bussmann KTS-R Series is the Eaton Bussmann LIMITRON fast-acting fuse family, engineered for reliable overcurrent protection in panelboards and electrical distribution equipment. This Class RK1 fuse family is available in ratings from 15A through 250A (KTS-R-15, KTS-R-20, KTS-R-25, KTS-R-30, KTS-R-60, KTS-R-100, and KTS-R-250), with every option carrying a 600 Vac rating and a 200 kAIC interrupt rating at 600 Vac for dependable short-circuit protection in demanding commercial and industrial applications. Each KTS-R fuse features a non-indicating design with blade end x blade end terminals for secure panelboard mounting, along with durable 70/30 brass end caps for long-lasting electrical contact. As a LIMITRON fast-acting fuse line, the KTS-R Series is engineered to respond quickly to overcurrent conditions, helping protect panelboards, feeders, and connected equipment from damaging fault currents. Electrical contractors and facility engineers rely on the KTS-R Series for code-compliant fuse protection across a wide range of 600 Vac panelboard systems.

Key Features

  • Amperage Range: Available from 15A up to 250A to cover a broad range of panelboard circuit protection needs.
  • Voltage Rating: 600 Vac rating across the series, suitable for commercial and industrial power distribution systems.
  • Interrupt Rating: 200 kAIC at 600 Vac provides high fault-current withstand capability for demanding installations.
  • Fuse Class: Class RK1 fuse classification for standardized, code-recognized panelboard protection.
  • LIMITRON Fast-Acting Design: Fast-acting LIMITRON construction responds quickly to overcurrent and short-circuit conditions.
  • Terminal Configuration: Blade end x blade end terminals for secure, reliable panelboard fuse holder mounting.
  • End Cap Construction: 70/30 brass end caps deliver durable, corrosion-resistant electrical contact points.
  • Non-Indicating Design: Standard non-indicating construction simplifies installation in panelboard fuse blocks across the series.

Technical Specifications

  • Amperage Range: 15A - 250A (KTS-R-15, KTS-R-20, KTS-R-25, KTS-R-30, KTS-R-60, KTS-R-100, KTS-R-250)
  • Voltage Rating: 600 Vac
  • Interrupt Rating: 200 kAIC at 600 Vac
  • Fuse Class: RK1
  • End Cap Material: 70/30 Brass
  • Terminal Style: Blade End x Blade End

Typical Applications

  • Panelboard Overcurrent Protection
  • Commercial and Industrial Electrical Distribution Systems
  • Branch Circuit Fuse Protection
  • Short-Circuit and Fault Current Protection
  • Feeder Circuit Protection in 600 Vac Systems
  • Electrical Equipment and Panelboard Retrofits

Why Bussmann?

Bussmann fuses are engineered by Eaton to deliver dependable, code-compliant overcurrent protection backed by rigorous construction standards. The KTS-R Series combines a 200 kAIC interrupt rating at 600 Vac with durable 70/30 brass end caps, giving electrical professionals confidence across the full 15A-250A range in demanding panelboard applications. As part of the trusted LIMITRON Class RK1 fast-acting fuse family, the KTS-R Series is built to help protect equipment, wiring, and personnel from damaging overcurrent conditions. Choose Bussmann for consistent, reliable fuse performance in commercial and industrial electrical systems.

Manufacturer Resources

Product Specs

Product Type:
Fast-Acting Fuse
Series:
KTS-R
Amperage Rating:
15A-250A
Voltage Rating:
600V
Standards:
Class RK1
Department:
Electrical
Product Subgroup:
Fuses
list_batch:
BUSS-20260919
Product Material:
Brass
Class:
Class RK1
Product Group:
Circuit Protection
Compliances:
CE Marked

Bussmann KTS-R-15 – Frequently Asked Questions

1) Will a Bussmann KTS-R fuse drop into my existing Class R fuse block?
The KTS-R is a Class RK1 fuse with blade end x blade end terminals, so it mounts in Class R rejection fuse blocks and holders sized for the same amp range. Class R clips are designed so only Class R fuses seat, which is why an RK1 like the KTS-R goes in where an older non-rejection Class H or K fuse will not. Match the amp rating of the holder to the fuse you order: 15, 20, 25, 30, 60, 100 or 250 amp.
2) Is the KTS-R fast-acting or time-delay? Will it hold a motor inrush?
The LIMITRON KTS-R is a fast-acting fuse, not a dual-element time-delay type. It clears overcurrent quickly, which suits panelboards, feeders and non-motor loads. For a motor circuit or anything with a heavy inrush, a fast-acting fuse sized to the running load will open on starting current - you want a time-delay Class RK1 such as the Bussmann FRS-R (600 Vac) for that application.
3) I have 60A Class H cartridge fuses in an old panel - can I upgrade to the KTS-R-60?
Only if the holder takes Class R fuses. The KTS-R-60 is Class RK1 with a rejection feature, so it will not seat in plain non-rejection Class H clips unless a Class R rejection kit is installed. Going the other way, the RK1 fuse is the upgrade you want for fault current, since a Class H fuse is only rated 10,000 amps interrupting against 200 kAIC for the KTS-R.
4) Which amp ratings does the KTS-R series come in?
Seven ratings across the 15A to 250A range: KTS-R-15, KTS-R-20, KTS-R-25, KTS-R-30, KTS-R-60, KTS-R-100 and KTS-R-250. Order by the amp number in the part code - that number is the fuse rating, and the holder has to be rated for the same class and amp band.
5) Does the KTS-R have a blown fuse indicator?
No. All KTS-R fuses are non-indicating, so there is no mechanical flag or window to show which one opened. On a three-phase feeder you will need to meter or pull each fuse to find the open leg. If visual indication matters for your maintenance crew, specify an indicating fuse or add an open-fuse indicating light at the panel.
6) Is the KTS-R suitable for branch circuit and feeder protection in a 600V commercial distribution system?
That is its main use. The KTS-R is applied for panelboard overcurrent protection, branch circuit and feeder protection, and short-circuit protection in 600 Vac systems, as well as retrofits of existing panelboards and distribution equipment. Class RK1 is a standardized, code-recognized class, so it slots into a specified fuse schedule without a substitution request.
How fast can I get the Bussmann KTS-R-15 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Bussmann KTS-R-15 come with a warranty?
Absolutely. The Bussmann KTS-R-15 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Bussmann KTS-R-15?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Bussmann KTS-R-15 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.