Bussmann T-4 Type T Time-Delay Dual-Element Plug Fuse, 4A 125VAC

The Bussmann T-4 is an Eaton Bussmann series Type T plug fuse built for heavy-duty, time-delay overcurrent protection in plug-fuse panelboards. This dual-element fuse is rated 4A at 125VAC and delivers a 10kAIC (RMS Symmetrical) interrupt rating along with a 10kA short circuit rating, giving installers and facility maintenance teams a dependable replacement option for legacy panels that still rely on Type T threaded plug fuses. The time-delay, dual-element construction allows the T-4 to ride through momentary overload conditions, such as motor starting inrush, without nuisance tripping, while still opening quickly on sustained overloads and short-circuit fault currents. The threaded mount base allows the fuse to thread directly into a compatible Type T plug-fuse holder, making replacement fast and straightforward without special tools.

Key Features

  • Amperage Rating: 4A rating is sized for branch-circuit and equipment overcurrent protection in plug-fuse panelboards.
  • Voltage Rating: 125VAC rating matches standard residential and light commercial plug-fuse panel voltage.
  • Time-Delay Operation: time-delay characteristic allows the fuse to hold through brief overload conditions, such as motor starting inrush current, reducing nuisance opening.
  • Dual-Element Construction: dual-element design combines a short-circuit element with a thermal overload element for balanced protection against both fault currents and sustained overloads.
  • Heavy Duty Rating: heavy-duty classification supports demanding overcurrent protection duty where reliable performance is required.
  • Interrupt Rating: 10kAIC (RMS Symmetrical) interrupt rating supports dependable fault clearing on high fault-current circuits.
  • Short Circuit Rating: 10kA short circuit rating provides an added layer of protection against damaging fault currents.
  • Threaded Mount: Type T threaded base installs directly into compatible Type T plug-fuse holders for quick, tool-free replacement.

Technical Specifications

  • Refer to manufacturer documentation for complete technical specifications.

Typical Applications

  • Residential and Light Commercial Plug-Fuse Panels
  • Legacy Panelboards Using Type T Threaded Fuse Holders
  • Motor and Equipment Circuits Requiring Time-Delay Protection
  • Branch Circuit Overcurrent Protection
  • Replacement Fuse for Existing Type T Fuse Holders

Why Bussmann?

Bussmann by Eaton has long been a trusted name in circuit protection, and the T-4 Type T plug fuse continues that reputation with time-delay, dual-element construction engineered for heavy-duty branch-circuit protection. Backed by a 10kAIC interrupt rating and a 10kA short circuit rating, this threaded-mount plug fuse gives electrical contractors and facility maintenance teams a dependable, code-compliant replacement for panels that use Type T plug fuses, helping keep legacy electrical systems protected and operating safely.

Manufacturer Resources

Product Specs

Product Type:
Plug Fuse
Voltage Rating:
125VAC
Connection Type:
Threaded
Series:
Type T
Department:
Electrical
Product Subgroup:
Fuses
list_batch:
BUSS-20260919
Installation Category:
Threaded
Product Details:
Time Delay
Interrupt Rating:
10 kiloamps
Product Group:
Circuit Protection

Bussmann T-2 – Frequently Asked Questions

1) Will a Bussmann Type T plug fuse thread into my existing fuse panel socket?
The Bussmann Type T plug fuse uses a threaded base that screws directly into a compatible Type T plug-fuse holder, so replacement takes no tools. It is a Type T base specifically, not an S-type (rejection base) fuse, so it will only go into a holder prepped for Type T. If your panel has had Type S adapters installed in the sockets, a Type T fuse will not thread in and you need the matching Type S fuse instead.
2) Why does my fuse blow on motor startup, and will a time-delay fuse fix it?
That is exactly what the dual-element time-delay design addresses. The Type T carries a thermal overload element alongside a short-circuit element, so it rides through the brief inrush of a motor starting without opening, then still clears on a sustained overload or a fault. If you are blowing fast-acting plug fuses on a small motor, compressor, or transformer load, a time-delay fuse of the same amp rating is the right swap.
3) What amp ratings does the Bussmann Type T time-delay plug fuse come in?
Two ratings: 2 amp (T-2) and 4 amp (T-4). Both are time-delay dual-element fuses rated 125VAC. Order by the amp rating that matches the circuit you are protecting, and never go up a size to stop a fuse blowing, the rating has to match the conductor and equipment it protects.
4) What interrupting rating does the Bussmann T-4 plug fuse have?
10 kA interrupting (10kAIC RMS symmetrical), with a 10kA short circuit rating. That matters when you are checking that the overcurrent device is rated for the available fault current at the panel, which is a question an inspector or facility engineer will ask on a legacy plug-fuse board. Ordinary non-time-delay plug fuses are often rated well below this.
5) Is a Type T plug fuse the right choice for an old fuse panel in a rental property?
If the panel's sockets are Type T threaded holders, yes, a Type T time-delay fuse is the direct like-for-like replacement and keeps the legacy board in service. Stocking a few 2A and 4A units covers low-amp branch and control circuits. For a property manager standardizing across units, note that the fuse must match the socket type in each panel, Type T and Type S bases are not interchangeable.
6) What is the difference between a dual-element and a single-element plug fuse?
A single-element fuse has one link that responds to both overload and fault current, so it opens quickly and can nuisance-blow on inrush. The Bussmann Type T is dual-element: one element handles short-circuit current, a separate thermal element handles sustained overload. That split is what gives it the time-delay characteristic and makes it suited to motor and equipment circuits rather than purely resistive lighting loads.
How fast can I get the Bussmann T-2 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Bussmann T-2 come with a warranty?
Absolutely. The Bussmann T-2 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Bussmann T-2?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Bussmann T-2 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.