Eaton Crouse-Hinds 4-11/16" Square Surface Cover for Two GFI Receptacles
Professional-Grade Steel Surface Cover with Raised Design for Enhanced Protection
The Eaton Crouse-Hinds 4-11/16" Square Surface Cover is a professional-grade electrical cover engineered for dual GFI receptacle installations in commercial and industrial environments. This steel construction surface cover delivers superior protection and code compliance with a raised surface design that accommodates two GFI receptacles while providing 9.0 cubic inches of capacity for electrical contractors and facility managers.
Key Features & Benefits
Superior Steel Construction
- Heavy-duty steel material - Provides exceptional durability and impact resistance in demanding environments
- Corrosion-resistant finish - Ensures long-term performance in various environmental conditions
- Professional-grade construction - Engineered to withstand decades of service in commercial applications
- Raised surface design - Offers enhanced protection for receptacles and improved accessibility
Dual GFI Receptacle Configuration
- Two GFI receptacle compatibility - Specifically designed to accommodate dual GFCI outlets for maximum safety
- 9.0 cubic inch capacity - Provides ample space for proper wire management and connections
- 4-11/16" square dimensions - Standard sizing ensures compatibility with existing electrical boxes
- Precise manufacturing tolerances - Guarantees proper fit and professional appearance
Code Compliance & Safety
- NEC/CEC compliant design - Meets all current electrical code requirements for surface covers
- Ordinary/non-hazardous location rated - Suitable for standard commercial and industrial applications
- Professional installation compatibility - Designed for efficient contractor installation and maintenance
- Enhanced electrical safety - Raised design provides additional protection for GFI receptacles
Technical Specifications
This surface cover features a 4-11/16 inch square configuration with steel construction and raised surface design. The unit provides 9.0 cubic inches of internal capacity specifically engineered for two GFI receptacles. With dimensions of 4.69 inches length and width, 0.06 inches height, and weighing 0.43 pounds, this cover offers the perfect balance of protection and accessibility. The steel material construction ensures superior durability compared to plastic alternatives, while the raised surface design provides enhanced protection for receptacles and improved wire management capabilities.
Installation Process
- Verify electrical power is disconnected and test circuits before beginning installation
- Ensure the existing 4-11/16" square electrical box is properly mounted and level
- Install both GFI receptacles in the electrical box according to manufacturer specifications
- Carefully route all conductors within the 9.0 cubic inch capacity, ensuring proper wire management
- Position the steel surface cover over the receptacles, aligning with mounting holes
- Secure the cover using appropriate screws, ensuring even pressure and proper seating
- Test GFI receptacles for proper operation and verify all connections are secure
Applications
Perfect for:
- Commercial Buildings - Office complexes, retail spaces, and professional facilities requiring dual GFI protection
- Industrial Facilities - Manufacturing plants, warehouses, and processing facilities with elevated safety requirements
- Healthcare Facilities - Hospitals, clinics, and medical offices where reliable GFI protection is critical
- Educational Institutions - Schools, universities, and training facilities requiring code-compliant electrical systems
- Food Service Operations - Restaurants, commercial kitchens, and food processing areas with moisture concerns
- Outdoor Applications - Covered outdoor areas where dual GFI receptacles provide enhanced electrical safety
- Equipment Rooms - Mechanical rooms, electrical panels, and utility areas requiring professional-grade covers
- Renovation Projects - Electrical upgrades and modernization projects requiring reliable surface-mounted solutions
Surface Cover System Benefits
Surface covers provide superior accessibility and maintenance advantages compared to flush-mounted alternatives. The raised design allows for easier receptacle access while providing enhanced protection from physical damage. This configuration is particularly valuable in commercial and industrial environments where frequent equipment connections and disconnections occur, as the raised surface reduces wear on both the receptacles and connecting plugs.
Why Choose Steel Construction?
Steel construction offers significant advantages over plastic alternatives, including superior impact resistance, enhanced fire safety, and long-term dimensional stability. The steel material provides excellent electromagnetic shielding properties while maintaining structural integrity under temperature variations. For electrical contractors and facility managers, steel surface covers represent a professional-grade solution that delivers decades of reliable service with minimal maintenance requirements, making them the preferred choice for commercial and industrial GFI receptacle installations.
Manufacturer Resources
Product Specs
- Area Classification:
- Ordinary/Non-Hazardous Locations
- Box Size:
- 4-11/16"
- Material:
- Steel
- Product Height:
- .06 in
- Product Length Depth:
- 4.69 in
- Product Weight:
- .43 lb
- Product Width:
- 4.69 in
- Standards Type:
- NEC/CEC
- Type:
- For two GFI receptacles
- Product Type:
- Surface Covers
- Product Group:
- Electrical Covers
- Department:
- Electrical
- Product Subgroup:
- Surface Covers