Detex 800 Series Electronic Ac...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$1,596.00
$1,086.94

Detex 800 Series Electronic Access Control Power Supply with 2.0A Output and Door Operator Signal

(No reviews yet) Write a Review

Model: 82-800

In Stock (leaves warehouse same day if ordered before 3pm ET)

$1,596.00
$1,086.94
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Detex 800 Series Electronic Access Control Power Supply with 2.0A Output and Door Operator Signal

Professional Power Management Solution for Electrified Door Hardware

The Detex 800 Series logic and power supply controller delivers reliable 24VDC power conversion from 120VAC input for commercial access control applications. This 2.0A continuous output unit powers and controls electrified door hardware accessories including Detex latch retraction exit devices (ER Electrified option) for one pair of doors. Features filtered and regulated power output with integrated battery charging circuit and standard signal output for automatic door operators.

Professional Features & Benefits

  • High-Capacity Power Output: 2.0A continuous current capacity provides reliable power for demanding electrified hardware applications.
  • Filtered and Regulated 24VDC: Converts 120VAC to stable 24VDC output with surge and spike protection to safeguard connected circuitry.
  • Integrated Battery Backup: Standard battery charging circuit maintains system operation during power outages (batteries sold separately).
  • Door Operator Integration: Standard output signal capability for automatic door operator control and coordination.
  • Multi-Door Capability: Designed to power and control electrified hardware for one pair of doors in commercial applications.
  • Access Control Compatibility: Optimized for Detex latch retraction exit devices and other electrified door hardware accessories.
  • Commercial-Grade Construction: 800 Series design engineered for reliable performance in demanding commercial environments.

Technical Specifications

  • Commercial/Residential: Commercial
  • Current: 2A
  • Electronic: Yes
  • Product Category: Electronic Access Controls
  • Product Group: Electronic Access Controls
  • Product Model: 82-800
  • Product Subgroup: Sensors, Switches, Relays and Timers
  • Product Type: Power Supplies
  • Series: 800 Series
  • Subcategory: Power Supply

Installation & Operation

  1. Verify electrical requirements match available power supply. Confirm 120VAC input and ensure adequate circuit capacity for 2.0A continuous load.
  2. Disconnect power supply before beginning installation. Follow all applicable electrical codes and safety procedures.
  3. Mount the unit in the specified location ensuring adequate clearance for wiring access, ventilation, and future service requirements.
  4. Route and connect wiring according to manufacturer wiring diagrams. Use appropriate wire gauge and connectors for the 2.0A output application.
  5. Configure operational settings including door operator signal output per application requirements.
  6. Restore power and test all functions including 24VDC output regulation, battery charging circuit operation, and integration with connected electrified hardware and door operators.
  7. Complete final inspection and document settings. Refer to manufacturer documentation for complete wiring diagrams, programming instructions, and troubleshooting.

Professional Applications

  • Commercial Building Security Systems
  • Educational Institution Access Control
  • Healthcare Facility Electronic Hardware
  • Retail Security and Access Management
  • Industrial Facility Entry Control
  • Multi-Tenant Residential Properties
  • Government and Municipal Buildings

Why Choose Detex Quality?

Detex 800 Series power supply controllers deliver professional-grade reliability with filtered and regulated power output designed for demanding commercial access control applications. The integrated battery charging circuit and door operator signal capability provide comprehensive system integration for modern security installations. Engineered for dependable performance in commercial environments where consistent power management is essential.

Installation Instructions (81-800)
Installation Instructions (82-800 / 83-800)

Product Specs

Subcategory:
Power Supply
Series:
800 Series
Product Group:
Electronic Access Controls
Product Subgroup:
Sensors, Switches, Relays and Timers
Product Type:
Power Supplies
Commercial/Residential:
Commercial
Electronic:
Yes
Current:
2A
Product Model:
82-800
Product Category:
Electronic Access Controls
Department:
Door Hardware

Detex 82-800 – Frequently Asked Questions

1) How many doors will the Detex 82-800 power supply run?
The Detex 82-800 controller and power supply is sized to power and control electrified latch retraction (ER option) Detex exit devices on one pair of doors, plus a signal output for one automatic door operator. If you have more than a pair of openings off the same panel, you need a larger controller or a second unit.
2) Will the Detex 82-800 keep an electrified exit device working during a power outage?
The 82-800 has a battery charging circuit built in, so it will maintain the system through a utility loss once batteries are connected. The batteries themselves are not included and have to be ordered separately.
3) Can I use this Detex controller to tie a low energy door operator into my exit devices?
Yes. A standard signal output on the 82-800 is there to coordinate an automatic door operator with the latch retraction hardware, so the latches pull before the operator swings the door. One operator per unit.
4) What is a 2 amp 24VDC alternative to the Detex 82-800 power supply for latch retraction hardware?
The Detex 82-800 delivers 2A at 24VDC from a 120VAC input and controls Detex ER latch retraction exit devices for one pair of doors. If you need another 2A unit, the Command Access PS204/204B is a linear power supply rated 2A at 24VDC with battery backup, the SDC 632 Series is a 2 amp regulated and filtered low voltage supply with dual voltage selection, and the Von Duprin PS902 is a 2A base power supply with field selectable 12/24VDC. The Detex unit is the one that carries a standard signal output for an automatic door operator.
5) Which power supply should I use instead of the Detex 82-800 if I need to power motorized latch retraction exit devices from another manufacturer?
The Detex 82-800 is matched to Detex ER electrified latch retraction exit devices. For a motorized latch retraction device from the BEST/Precision line, the BEST RPSMLR2 Series is a power supply built for motorized latch retraction exit devices, and the BEST ELR150 Series is a power supply control module for electronic access control. For a delayed egress device, the BEST PS161-6 takes 120V input with 12/24V output at 6A capacity.
6) What should I specify instead of the Detex 82-800 when the job needs multiple fused outputs for a whole access control panel?
The Detex 82-800 is a single 24VDC supply and controller for one pair of doors. If the drawing calls for distributed outputs, the Altronix AL1024ULACMCB is a power supply and access power controller with 115VAC 60Hz input at 4.2A and eight PTC outputs delivering 24VDC at 10A in a grey enclosure, and the RCI DKPS-2A offers eight outputs at 12/24VDC and 2A. For high-current 12VDC loads, the Securitron AQS1210 is a 12VDC 10 amp switching supply.
7) If the load on the pair of doors exceeds 2 amps, what is a higher capacity alternative to the Detex 82-800?
The Detex 82-800 is rated 2A continuous. For more headroom, the SDC 634 Series is a 4 amp regulated and filtered low voltage supply with dual voltage selection, the Securitron AQL4 is a switching supply at 12/24VDC rated 4/3 amp, and the BEST PS161-6 offers 6A capacity with 120V input and 12/24V output.
8) Is the 82-800 a plain power supply or does it actually control the exit devices?
It is both. Detex calls it a logic and power supply controller: it converts and regulates the 24VDC and also sequences the latch retraction devices and the operator signal. A plain transformer style supply, like the Command Access PS1 24VDC 1 amp linear unit, only supplies power and leaves the logic to something else.
9) I need to power motorized latch retraction on more openings than one pair. What should I look at?
Step up in capacity. The 82-800 stops at 2.0A continuous and one pair of doors. For bigger loads, the Altronix AL1024ULACMCB is a 24VDC 10A access power controller with eight PTC outputs off a 115VAC 60Hz input, the SDC 634 is a 4 amp regulated dual voltage supply, and the BEST PS161-6 is a 120V input, 12/24V output 6A unit. The BEST RPSMLR2 is built specifically for motorized latch retraction devices.
10) Does the Detex 82-800 work with exit devices from other brands?
Detex specifies the 82-800 for its own electrified latch retraction exit devices (the ER option) and other electrified door hardware accessories. For latch retraction on another manufacturer's device, use that maker's controller, for example the BEST RPSMLR2 for motorized latch retraction exit devices.
11) What is the difference between the Detex 82-800 and the SDC 631 or SDC 632 power controllers?
The SDC 631 Series is a 1.5 amp regulated and filtered DC power controller and the SDC 632 Series is a 2 amp regulated and filtered supply, both with dual voltage selection, so one unit can be set for either output voltage. The Detex 82-800 is a 2A 24VDC logic and power supply controller with an integrated battery charging circuit and a standard signal output for an automatic door operator, matched to Detex ER latch retraction devices.
12) I only need to power one electric strike, not a pair of doors. Is there a smaller option than the Detex 82-800?
The Detex 82-800 is sized at 2A continuous to power and control hardware for one pair of doors. For a single low-draw device, smaller supplies include the Command Access PS1 Series at 1 amp 24VDC, the SDC 620 Series 1 amp regulated and filtered supply with dual voltage selection, the Securitron AQD1 switching supply at 12/24VDC 1 amp, and the Adams Rite PS-1 regulated supply at 1 amp 12/24VDC with battery backup.
13) Is the ROFU 10305-LA a substitute for the Detex 82-800?
No. The ROFU 10305-LA/10306-LA is a tamper resistant power transfer hinge rated 1.5A at 42V in a white plastic finish - it carries current from frame to door, it does not convert line voltage. The Detex 82-800 is the 120VAC to 24VDC supply and controller at 2A. On an electrified opening you may well need both.
14) I need a UL listed power supply for an access control kit rather than the Detex 82-800. What is comparable?
The Aiphone AC-PS1250 is a UL listed 12VDC 5A supply made for Aiphone AC Series access control kits, and the Command Access PS210 is a UL 6E/CSA linear supply rated 1.5A at 24VDC with boost circuitry. The Von Duprin PS902 is a Grade 1 2A base power supply with field selectable 12/24VDC. The Detex 82-800 remains the choice where you need the 24VDC output plus the operator signal for a Detex ER pair.
15) Is there an alternative to the Detex 82-800 for an opening with no 120VAC available?
The Detex 82-800 requires a 120VAC input to produce its regulated 24VDC output. Where line voltage is not run to the location, the Securitron BPSS is a boxed solar power supply. Plug-in options include the ROFU 9126T mini power supply at 12VDC 1.5A with time delay, and the ROFU 9102-12D UL/9102-24D operates on 10/120VAC 60Hz input.
16) Is the Detex 82-800 suitable for a residential application?
It is classed as commercial hardware, built for building security, schools, healthcare, retail, industrial entries, multi-tenant residential properties and government facilities. For a single house door, a small plug-in unit such as the ROFU 9126T mini supply is the more sensible scale.
17) What do I need to check on the branch circuit before installing the Detex 82-800?
Confirm you have 120VAC available and that the circuit has capacity for the 2.0A continuous draw of the unit. Mount it with clearance for wiring access, ventilation and later service, wire per the Detex diagrams with gauge suited to a 2.0A output, then power up and verify 24VDC regulation, the battery charging circuit and the operator signal.
18) Does the Command Access CAT Field Tester replace a Detex 82-800 on an install?
No. The Command Access CAT Field Tester is a portable 12-24VDC test supply that runs off DeWalt, Makita and Milwaukee batteries, intended for bench and field testing of hardware. The Detex 82-800 is the permanently mounted 120VAC to 24VDC supply and controller for the finished opening.
How fast can I get the Detex 82-800 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Detex 82-800 come with a warranty?
Absolutely. The Detex 82-800 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Detex 82-800?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Detex 82-800 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.