Eaton GFCI Circuit Breaker 15A Single-Pole CH Series Plug-On Neutral
Professional Ground Fault Circuit Interrupter Protection
The Eaton CH GFCI Circuit Breaker delivers exceptional electrical protection and ground fault circuit interruption for residential and commercial applications. This 15A single-pole GFCI breaker with 10kAIC interrupt rating provides reliable electrical protection and ground fault safety designed for professional electricians, electrical contractors, and facility managers, offering the proven reliability and advanced technology that professionals trust from the global leader in intelligent power management.
Professional Features & Benefits
Ground Fault Protection Performance
- 15A Single-Pole Configuration - Provides reliable overcurrent protection and ground fault interruption for 120V branch circuits in residential and commercial electrical systems
- 10kAIC Interrupt Rating - Delivers professional-grade short circuit protection capability for safe electrical fault clearing in standard electrical distribution systems
- CH Series Compatibility - Engineered specifically for Eaton CH load centers and electrical panels, ensuring proper fit and reliable electrical connections
- Plug-On Neutral Design - Features innovative plug-on neutral connection for simplified installation and enhanced electrical safety in GFCI applications
Installation & Safety Features
- UL Listed Certification - Meets rigorous electrical safety standards for professional electrical installations and code compliance
- Compact Design - 4.5" x 3.25" x 0.75" dimensions and 0.5 lb weight for efficient panel space utilization
- Professional Construction - Built with quality materials and precision engineering for long-term electrical performance and reliability
Technical Specifications
Amperage Rating: 15A, Number of Poles: Single-pole, Interrupt Rating: 10kAIC, Circuit Breaker Type: CH, Special Features: Plug-on neutral, Type: GFCI circuit breakers, Dimensions: 4.5" L x 3.25" H x 0.75" W, Weight: 0.5 lb, Certifications: UL Listed
Installation & Usage
- Verify power is OFF and test electrical panel for proper voltage isolation before beginning installation
- Remove appropriate knockout in CH series load center and position GFCI breaker in designated single-pole slot
- Connect hot wire to breaker terminal and utilize plug-on neutral feature for proper neutral connection
- Secure breaker firmly into panel bus connection ensuring proper electrical contact
- Test GFCI function using test and reset buttons to verify proper ground fault protection operation
- Label circuit clearly and document GFCI protection for electrical system records and maintenance
Professional Applications
Ideal for:
- Residential GFCI Protection - Bathroom circuits, kitchen countertop outlets, outdoor receptacles, and wet location electrical protection
- Commercial Ground Fault Safety - Office buildings, retail spaces, and commercial facilities requiring GFCI protection for personnel safety
- Electrical Code Compliance - Meeting NEC requirements for GFCI protection in specified locations and electrical applications
- Wet Location Protection - Garages, basements, crawl spaces, and areas where moisture may be present
- Construction Site Safety - Temporary electrical installations and construction power distribution requiring ground fault protection
- Pool and Spa Circuits - Swimming pool equipment, hot tub installations, and aquatic facility electrical systems
- Outdoor Electrical Systems - Landscape lighting, outdoor receptacles, and exterior electrical equipment protection
- Workshop and Garage Circuits - Power tool outlets, workbench electrical supply, and automotive service electrical systems
CH Series Advantage
The CH series represents Eaton's commitment to residential and light commercial electrical protection with proven thermal-magnetic trip technology and reliable GFCI ground fault detection. The plug-on neutral design simplifies installation while ensuring proper neutral connection for optimal GFCI performance and electrical safety.
Why Choose Eaton Quality?
With over a century of electrical power management innovation, Eaton delivers the quality, reliability, and safety that electrical professionals demand. Our UL Listed GFCI circuit breakers provide the electrical protection and ground fault safety that electricians, electrical contractors, and facility professionals trust worldwide, backed by comprehensive testing and proven performance in millions of electrical installations.
Manufacturer Resources
Product Specs
- Amperage Rating:
- 15 A
- Application:
- CH GFCI Breaker, 15A, PON, 10kAIC
- Certifications:
- UL Listed
- Circuit Breaker Type:
- CH
- Interrupt Rating:
- 10 kAIC
- Number Of Poles:
- Single-pole
- Product Height:
- 3.25 in
- Product Length Depth:
- 4.5 in
- Product Weight:
- .5 lb
- Product Width:
- .75 in
- Special Features:
- Plug-on neutral
- Product Group:
- Electrical
- Department:
- Electrical
- Product Details:
- GFCI circuit breakers