Eaton Main Breaker Loadcenter 100A 30-Space 60-Circuit 120/240V Single-Phase CH Series NEMA 1
Professional Electrical Distribution Panel for Residential and Commercial Applications
The Eaton Main Breaker Loadcenter delivers exceptional electrical power distribution performance for residential and commercial electrical systems. This 100A single-phase loadcenter with 30 spaces and 60 circuits provides reliable electrical distribution designed for professional electricians, electrical contractors, and facility managers, offering the proven reliability and advanced technology that professionals trust from the global leader in intelligent power management.
Professional Features & Benefits
Electrical Distribution Performance
- 100A Main Breaker Capacity - Provides reliable overcurrent protection and electrical distribution for residential and light commercial applications with professional-grade performance
- 30 Spaces with 60 Circuit Capacity - Accommodates up to 60 circuits in 30 spaces allowing for tandem breaker installation and maximum electrical distribution flexibility
- 120/240V Single-Phase Configuration - Standard residential voltage rating perfect for homes, apartments, and light commercial electrical systems
- 10 kAIC Interrupt Rating - Professional interrupting capacity handles fault currents safely in typical residential and commercial electrical applications
Professional Construction & Protection
- CH Series Main Circuit Breaker - Eaton CH series thermal-magnetic main breaker provides reliable overcurrent protection with proven electrical performance
- Copper Bus Construction - High-conductivity copper bus material ensures excellent electrical conductivity and long-term reliability in power distribution
- NEMA 1 Metallic Enclosure - Professional indoor enclosure provides protection against accidental contact with live parts in dry locations
Installation & Wiring Features
- PON (Plug-On Neutral) Technology - Advanced plug-on neutral system simplifies AFCI and GFCI breaker installation while reducing installation time
- #6-1/0 AWG Wire Compatibility - Accommodates professional wire sizes for main service entrance connections with secure termination
- Three-Wire Service Ready - Designed for standard three-wire single-phase electrical service entrance applications
Technical Specifications
Amperage Rating: 100A, Voltage Rating: 120/240V, Phase: Single-phase, Number of Spaces: 30, Number of Circuits: 60, Main Circuit Breaker: CH Series, Interrupt Rating: 10 kAIC, Enclosure: NEMA 1, Enclosure Material: Metallic, Bus Material: Copper, Wire Size: #6-1/0 AWG, Number of Wires: 3, Special Features: PON (Plug-On Neutral), Dimensions: 29" L x 14.31" W x 3.88" H, Weight: 15.6 lbs, Certifications: UL 50
Installation & Usage
- Mount loadcenter securely to wall or electrical panel board in dry indoor location per NEC requirements
- Connect main service entrance conductors (#6-1/0 AWG) to main breaker terminals following proper torque specifications
- Install grounding and neutral conductors to designated bus bars ensuring proper electrical bonding
- Install individual circuit breakers in designated spaces, utilizing PON technology for AFCI/GFCI breakers when required
- Connect branch circuit conductors to circuit breakers following amperage ratings and wire size requirements
- Complete electrical connections, verify proper operation, and install cover with appropriate labeling
Professional Applications
Ideal for:
- Residential Electrical Systems - Single-family homes, townhouses, and residential electrical service upgrades requiring reliable power distribution
- Light Commercial Applications - Small offices, retail spaces, and commercial buildings with moderate electrical loads
- Electrical Service Upgrades - Replacing older electrical panels with modern safety features and increased circuit capacity
- New Construction Projects - Residential and light commercial new construction requiring professional electrical distribution
- Apartment and Condominium Units - Individual unit electrical panels in multi-family residential buildings
- Workshop and Garage Applications - Detached garages, workshops, and outbuildings requiring dedicated electrical distribution
- Electrical Contractor Projects - Professional installations requiring reliable loadcenters with modern safety features
- Code Compliance Upgrades - Electrical system modernization to meet current NEC requirements and safety standards
PON Technology Advantage
The integrated Plug-On Neutral (PON) technology simplifies installation of AFCI and GFCI circuit breakers by eliminating the need for pigtail neutral connections. This innovative design reduces installation time, improves reliability, and ensures proper neutral connections for enhanced electrical safety in residential and commercial applications.
Why Choose Eaton Quality?
Eaton's century-plus experience in electrical power management innovation ensures this loadcenter delivers the reliability and performance that professional electricians and electrical contractors demand. With UL 50 certification, proven CH series circuit breaker technology, and commitment to electrical safety standards, Eaton loadcenters provide the trusted performance for residential and commercial electrical distribution systems worldwide.
Manufacturer Resources
Product Specs
- Amperage Rating:
- 100 A
- Box Size:
- X5
- Bus Material:
- Copper
- Catalog Notes:
- Purchase Size X5 Cover Separately
- Certifications:
- UL 50
- Enclosure:
- NEMA 1
- Enclosure Material:
- Metallic
- Interrupt Rating:
- 10 kAIC
- Main Circuit Breaker:
- CH
- Number Of Circuits:
- 60
- Number Of Spaces:
- 30
- Number Of Wires:
- 3
- Phase:
- Single-phase
- Product Height:
- 3.88 in
- Product Length Depth:
- 29 in
- Product Weight:
- 15.6 lb
- Product Width:
- 14.31 in
- Special Features:
- PON
- Voltage Rating:
- 120/240 V
- Wire Size:
- #6-1/0 AWG
- Product Group:
- Electrical
- Type of Cover:
- X5
- Department:
- Electrical
- Product Details:
- Main breaker