You may also like

Eaton Z48G31T75 Class 1 Div. 2 Groups A, B, C, and D Hazardous Location Transformer, EPTZ, Three-phase, Primary voltage: 480V, Taps: 2 at -5% FCBN, Secondary voltage: 220Y/127V, 115°C, 75 kVA, Aluminum windings, FR245H, 66A, Indoor-Outdoor, 60 Hz, NE
Model: EAT-Z48G31T75
Class 1 Div. 2 Groups A, B, C, and D Hazardous Location Transformer, EPTZ, Three-phase, Primary voltage: 480V, Taps: 2 at -5% FCBN, Secondary voltage: 220Y/127V, 115°C, 75 kVA, Aluminum windings,...
Eaton
$28,532.41
$28,482.41
Sale

Eaton Z48G22T06X Class 1 Div. 2 Groups A, B, C, and D Hazardous Location Transformer, EPTZ, Three-phase, Primary voltage: 480V, Taps: 2 at -5% FCBN, Secondary voltage: 240/120V, 115°C, 6 kVA, Aluminum windings, FR95H, 52A, Indoor-Outdoor, 50/60 Hz, N
Model: EAT-Z48G22T06X
Class 1 Div. 2 Groups A, B, C, and D Hazardous Location Transformer, EPTZ, Three-phase, Primary voltage: 480V, Taps: 2 at -5% FCBN, Secondary voltage: 240/120V, 115°C, 6 kVA, Aluminum windings,...
Eaton
$7,461.07
$7,411.07
Sale

Eaton Z48G37T25 Class 1 Division 2 Groups C and D, Hazardous Location Transformer, EPTZ, Three-phase, PV: 480V, Taps: 2 at -5% FCBN, SV: 380Y/220V, 115°C, 25 kVA, Al windings, Frame: 243H, Indoor-Outdoor
Model: EAT-Z48G37T25
Class 1 Division 2 Groups C and D, Hazardous Location Transformer, EPTZ, Three-phase, PV: 480V, Taps: 2 at -5% FCBN, SV: 380Y/220V, 115°C, 25 kVA, Al windings, Frame: 243H, Indoor-Outdoor
Eaton
$16,610.39
$16,560.39
Sale

Eaton Z48G37T45CU Class 1 Division 2 Groups C and D, Hazardous Location Transformer, EPTZ, Three-phase, PV: 480V, Taps: 2 at -5% FCBN, SV: 380Y/220V, 115°C, 45 kVA, Cu windings, Frame: 244H, Indoor-Outdoor
Model: EAT-Z48G37T45CU
Class 1 Division 2 Groups C and D, Hazardous Location Transformer, EPTZ, Three-phase, PV: 480V, Taps: 2 at -5% FCBN, SV: 380Y/220V, 115°C, 45 kVA, Cu windings, Frame: 244H, Indoor-Outdoor
Eaton
$31,411.30
$31,361.30
Sale

Eaton Z48G28T15CUS6 Class 1 Division 2 Groups A, B, C, and D Hazardous Location Transformer, EPTZ, Three-phase, Primary voltage: 480V, Taps: 2 at -5% FCBN, Secondary voltage: 208Y/120V, 115°C, 15 kVA, Copper windings, FR95H, 70A, 60 Hz, NEMA 3R
Model: EAT-Z48G28T15CUS6
Class 1 Division 2 Groups A, B, C, and D Hazardous Location Transformer, EPTZ, Three-phase, Primary voltage: 480V, Taps: 2 at -5% FCBN, Secondary voltage: 208Y/120V, 115°C, 15 kVA, Copper windings,...
Eaton
$19,753.19
$19,703.19
Sale
Eaton Class 1 Div. 2 Groups A, B, C, and D Hazardous Location Transformer, EPTZ, Three-phase, Primary voltage: 480V, Taps: 2 at -5% FCBN, Secondary voltage: 380Y/220V, 115°C, 50 kVA, Aluminum windings, FR245H, 66A, Indoor-Outdoor, 60 Hz
Manufacturer Resources
Product Specs