Eaton GFCI Circuit Breaker 20A Single-Pole 120/240V 10kAIC CLGF Trip-to-Center Plug-On
Professional Ground Fault Circuit Interrupter Protection
The Eaton GFCI Circuit Breaker delivers exceptional ground fault protection and electrical safety performance for residential and commercial electrical applications. This 20A single-pole ground fault circuit interrupter provides reliable electrical protection with 10kAIC interrupt rating designed for professional electricians, electrical contractors, and facility managers, offering the proven reliability and advanced technology that professionals trust from the global leader in intelligent power management.
Professional Features & Benefits
Ground Fault Protection Performance
- 20 Ampere Current Rating - Provides reliable overcurrent protection for 20A branch circuits with professional-grade electrical performance and safety compliance
- Single-Pole Configuration - Optimized for 120V branch circuit protection in residential and light commercial electrical panel applications
- 10kAIC Interrupt Rating - Delivers dependable short-circuit protection capability for standard residential and commercial electrical distribution systems
- 120/240V Voltage Rating - Versatile voltage compatibility for diverse electrical system configurations and professional installation requirements
Installation & Safety Features
- Plug-On Connection Design - Simplified installation with secure plug-on mounting method for quick and reliable electrical panel integration
- Trip-to-Center Mechanism - Clear visual indication of tripped condition for easy identification and professional troubleshooting during electrical service calls
- #14-8 AWG Wire Compatibility - Accommodates standard residential and commercial wiring sizes for versatile electrical installation applications
Technical Specifications
Amperage Rating: 20A, Voltage Rating: 120/240V, Number of Poles: Single-pole, Interrupt Rating: 10kAIC, Wire Size: #14-8 AWG, Mounting Method: Plug-on, Trip Type: Trip-to-center, Circuit Protection: Ground fault circuit interrupter, Product Dimensions: 4" L x 3.5" W x 1" H, Product Weight: 0.45 lb, Series: CLGF, Certifications: Contact Manufacturer
Installation & Usage
- Verify electrical panel compatibility and ensure power is safely disconnected before beginning GFCI circuit breaker installation
- Remove existing circuit breaker from electrical panel and disconnect branch circuit wiring following proper electrical safety procedures
- Install Eaton GFCI circuit breaker using plug-on connection method, ensuring secure attachment to panel bus bar
- Connect branch circuit hot wire to circuit breaker load terminal and neutral wire to GFCI neutral terminal
- Test GFCI function using test and reset buttons to verify proper ground fault protection operation
- Restore electrical power and verify circuit operation, documenting installation for electrical code compliance and future service reference
Professional Applications
Ideal for:
- Residential Electrical Systems - Kitchen, bathroom, laundry, and outdoor outlet circuits requiring ground fault protection per NEC requirements
- Commercial Building Protection - Office buildings, retail spaces, and light commercial facilities needing GFCI protection for personnel safety
- Electrical Panel Upgrades - Modernizing existing electrical panels with advanced ground fault circuit interrupter technology for enhanced safety
- Code Compliance Projects - Meeting National Electrical Code requirements for GFCI protection in specified locations and applications
- Electrical Contractor Services - Professional electrical installations requiring reliable ground fault protection with visual trip indication
- Facility Maintenance - Replacement and upgrade applications in existing electrical distribution systems for improved personnel protection
- New Construction Electrical - Residential and commercial new construction projects requiring GFCI protection for wet and outdoor locations
- Electrical Safety Systems - Critical ground fault protection applications where personnel safety and electrical code compliance are essential
Ground Fault Protection Advantage
Eaton's GFCI circuit breaker technology provides superior ground fault detection and interruption capability, protecting personnel from dangerous ground fault conditions while maintaining reliable electrical service. The trip-to-center mechanism provides clear visual indication of ground fault trips, enabling quick identification and professional troubleshooting for electrical contractors and facility maintenance personnel.
Why Choose Eaton Quality?
With over a century of electrical power management innovation, Eaton delivers unmatched quality and reliability in ground fault circuit interrupter technology. Our commitment to electrical safety standards, professional-grade construction, and comprehensive testing ensures dependable performance that electricians, electrical contractors, and facility professionals trust worldwide for critical personnel protection applications.
Manufacturer Resources
Product Specs
- Amperage Rating:
- 20 A
- Certifications:
- Contact Manufacturer
- Circuit Protection:
- Ground fault circuit interrupter
- Connection:
- Plug-on
- Indicators:
- GFI
- Interrupt Rating:
- 10 kAIC
- Main Circuit Breaker:
- CLGF
- Mounting Method:
- Plug-on
- Number Of Poles:
- Single-pole
- Product Height:
- 1 in
- Product Length Depth:
- 4 in
- Product Type:
- Gfci Circuit Breaker
- Product Weight:
- .45 lb
- Product Width:
- 3.5 in
- Trip Rating:
- 15 A
- Trip Type:
- Trip-to-center
- Voltage Rating:
- 120/240 V
- Wire Size:
- #14-8 AWG
- Product Subgroup:
- Circuit Breaker
- Department:
- Electrical