Eaton Thermal Magnetic Circuit Breaker 35A Two-Pole 120/240V 10kAIC CL Type CH Compatible
Professional Classified Replacement Circuit Breaker for Type CH Loadcenters
The Eaton Thermal Magnetic Circuit Breaker delivers exceptional electrical protection performance for residential and commercial electrical systems. This 35A two-pole circuit breaker provides reliable thermal-magnetic protection designed for professional electricians, electrical contractors, and facility managers, offering the proven reliability and advanced technology that professionals trust from the global leader in intelligent power management.
Professional Features & Benefits
Electrical Protection Performance
- 35 Ampere Rating - Provides reliable overcurrent protection for medium-load residential and commercial circuits with precise thermal-magnetic trip characteristics
- Two-Pole Configuration - Delivers simultaneous protection for both hot conductors in 240V applications with common trip operation
- 10 kAIC Interrupt Rating - Safely interrupts fault currents up to 10,000 amperes for comprehensive electrical system protection
- 120/240V Voltage Rating - Compatible with standard residential and light commercial electrical systems for versatile installation applications
Installation & Compatibility
- Type CH Loadcenter Compatibility - Direct replacement for Type CH electrical panels ensuring proper fit and electrical connection
- Common Trip Operation - Both poles trip simultaneously for enhanced electrical safety and system protection
- #14-4 AWG Cu/Al Wire Compatibility - Accommodates copper and aluminum conductors for flexible wiring applications
Professional Quality Construction
- UL 489 Certified - Meets rigorous safety standards for molded case circuit breakers ensuring code compliance
- Classified Replacement Design - Engineered as direct replacement for multiple manufacturer breaker types including Square D Homeline, GE Type THQ, and others
Technical Specifications
Amperage Rating: 35A, Voltage Rating: 120/240V, Number of Poles: Two-pole, Interrupt Rating: 10 kAIC, Trip Type: Common breaker trip, Wire Size: #14-4 AWG Cu/Al, Circuit Breaker Type: CH, Main Circuit Breaker: CL, Certifications: UL 489, Product Dimensions: 3" H x 2" W x 2.5" D, Product Weight: 0.5 lb, Used With: Type CH Loadcenters
Installation & Usage
- Turn off main power and verify electrical system is de-energized using proper testing equipment
- Remove existing breaker from Type CH loadcenter by pulling straight out from bus connection
- Insert new Eaton circuit breaker firmly into loadcenter until fully seated on bus bars
- Connect circuit conductors to breaker terminals ensuring proper torque specifications
- Verify proper breaker operation by testing trip mechanism before energizing circuit
- Restore power and test circuit operation to confirm proper installation and protection
Professional Applications
Ideal for:
- Residential Electrical Systems - Main panel protection for 240V appliances, HVAC systems, and high-amperage household circuits
- Commercial Building Protection - Light commercial electrical distribution for office buildings, retail spaces, and small industrial facilities
- HVAC System Protection - Dedicated circuit protection for air conditioning units, heat pumps, and electrical heating systems
- Appliance Circuit Protection - Electric water heaters, electric dryers, ranges, and other 240V appliances requiring 35A protection
- Panel Upgrade Projects - Electrical contractor installations for panel modernization and code compliance upgrades
- Maintenance Replacement - Direct replacement for failed or outdated circuit breakers in existing Type CH electrical panels
- Multi-Family Housing - Apartment complexes, condominiums, and townhomes requiring reliable electrical protection
- Small Commercial Applications - Restaurants, shops, and service businesses with moderate electrical loads
Thermal-Magnetic Protection Advantage
Eaton's thermal-magnetic circuit breaker technology combines bimetallic thermal elements for overload protection with magnetic trip units for short-circuit protection, providing comprehensive electrical system safety. The thermal element responds to sustained overcurrent conditions while the magnetic element provides instantaneous protection against dangerous fault currents, ensuring reliable operation across all electrical load conditions.
Why Choose Eaton Quality?
With over a century of electrical power management innovation, Eaton leads the industry in intelligent power solutions trusted by electricians, electrical contractors, and facility professionals worldwide. Every Eaton circuit breaker undergoes rigorous testing and quality control processes, backed by UL certification and engineered for long-term reliability in demanding electrical applications. Choose Eaton for proven performance, electrical safety compliance, and the professional-grade quality that electrical professionals depend on for critical power protection applications.
Manufacturer Resources
Product Specs
- Amperage Rating:
- 35 A
- Catalog Notes:
- Replacement for Square D Homeline, GE Type THQ, Crouse-Hinds Type MP, Thomas and Betts Type TB, Murray Type MP, ITE/Siemens Type QP. Requires Two 1-inch (25.4 mm) spaces.
- Certifications:
- UL 489
- Circuit Breaker Type:
- CH
- Interrupt Rating:
- 10 kAIC
- Main Circuit Breaker:
- CL
- Number Of Poles:
- Two-pole
- Product Height:
- 3 in
- Product Length Depth:
- 2.5 in
- Product Type:
- Thermal Magnetic Circuit Breaker
- Product Weight:
- .5 lb
- Product Width:
- 2 in
- Trip Type:
- Common breaker trip
- Used With:
- Type CH Loadcenters
- Voltage Rating:
- 120/240 V
- Wire Size:
- #14-4 AWG Cu/Al
- Product Group:
- Electrical
- Product Subgroup:
- Circuit Breaker
- Department:
- Electrical