Eaton Surge Protection Device Type 2 Service Entrance 120/240V Single-Phase NEMA 4 20kA Nominal Discharge
Professional Electrical Surge Protection Equipment
The Eaton Type 2 Service Entrance Surge Protection Device delivers exceptional electrical power protection performance for residential and commercial electrical service entrance applications. This 120/240V single-phase surge protector provides reliable electrical surge protection designed for professional electricians, electrical contractors, and facility managers, offering the proven reliability and advanced technology that professionals trust from the global leader in intelligent power management.
Professional Features & Benefits
Advanced Surge Protection Performance
- 20 kA Nominal Discharge Current Rating - Provides robust surge current handling capacity for reliable protection against electrical transients and power surges
- 108 kA Surge Current Capacity - Delivers exceptional surge withstand capability for maximum electrical system protection during severe surge events
- 200 kAIC Interrupt Rating - Ensures reliable fault current interruption performance for comprehensive electrical system protection
- 22 kA Short Circuit Current Rating - Provides dependable short circuit protection performance for enhanced electrical safety
Voltage Protection & Operating Specifications
- 120/240V Line Voltage Rating - Optimized for standard residential and light commercial electrical service entrance applications
- 150V L-N, 300V L-L Maximum Continuous Operating Voltage - Ensures proper surge protection device operation within normal voltage parameters
- Comprehensive Voltage Protection Ratings - Features 600V L-N, 1000V L-L, 800V N-G, and 600V L-G voltage protection ratings for complete electrical system protection
Professional Installation & Environmental Protection
- NEMA 4 Enclosure Rating - Provides weatherproof protection for outdoor and harsh environment installations with dust and water resistance
- Single-Phase 60 Hz Operation - Designed for standard North American electrical system compatibility and reliable performance
- Compact 7" x 5" x 2.5" Dimensions - Space-efficient design facilitates easy installation in electrical service entrance panels and equipment
Technical Specifications
Voltage Rating: 120/240V, Phase: Single-phase, Frequency: 60 Hz, Nominal Discharge Current: 20 kA, Surge Current: 108 kA, Interrupt Rating: 200 kAIC, Short Circuit Rating: 22 kA, Maximum Continuous Operating Voltage: 150V L-N, 300V L-L, Voltage Protection: 600V L-N, 1000V L-L, 800V N-G, 600V L-G, Enclosure: NEMA 4, Operating Temperature: -40 to 50°C, Dimensions: 7" L x 5" W x 2.5" H, Weight: 1 lb, Certifications: cUL Certified, Compliance: IBC 2006, CBC 2007, UBC Zone 4 requirements
Installation & Usage
- Verify electrical service entrance panel compatibility and available mounting space for surge protection device installation
- Ensure electrical power is safely disconnected and follow proper lockout/tagout procedures before beginning installation
- Mount surge protection device in appropriate location within service entrance panel or adjacent to main electrical disconnect
- Connect surge protector to electrical system according to manufacturer wiring diagrams and local electrical codes
- Verify proper grounding connections and surge protection device indicator status after installation
- Test surge protection device operation and document installation for electrical system maintenance records
Professional Applications
Ideal for:
- Residential Service Entrance Protection - Primary surge protection for single-family homes, townhomes, and residential electrical service panels
- Commercial Building Electrical Systems - Service entrance surge protection for small commercial buildings, retail facilities, and office complexes
- Light Industrial Electrical Applications - Surge protection for workshops, small manufacturing facilities, and industrial electrical distribution systems
- Electrical Panel Protection - Service entrance surge suppression for main electrical panels, load centers, and distribution equipment
- Critical Equipment Protection - Upstream surge protection for sensitive electronic equipment, computer systems, and telecommunications infrastructure
- HVAC System Protection - Electrical surge protection for heating, ventilation, and air conditioning equipment and controls
- Outdoor Electrical Installations - Weather-resistant surge protection for outdoor electrical equipment and service entrance applications
- Lightning Protection Systems - Coordinated surge protection as part of comprehensive lightning protection and electrical safety systems
Type 2 Surge Protection Advantage
Eaton's Type 2 service entrance surge protection devices provide the critical first line of defense against electrical transients and power surges entering electrical systems. The robust 20 kA nominal discharge current rating and 108 kA surge current capacity ensure reliable protection during severe electrical events, while the comprehensive voltage protection ratings safeguard all electrical system conductors. The NEMA 4 weatherproof enclosure enables reliable outdoor installation performance in harsh environmental conditions.
Why Choose Eaton Quality?
Eaton's century-plus experience in electrical power management innovation delivers surge protection devices engineered for maximum reliability and electrical safety performance. With cUL certification and compliance with IBC, CBC, and UBC building code requirements, Eaton surge protectors provide the proven quality and dependable protection that electricians, electrical contractors, and facility professionals trust worldwide for critical electrical system protection applications.
EAT-CHSPT2ULTRA - spec sheet
Manufacturer Resources
Product Specs
- Certifications:
- cUL Certified
- Enclosure:
- NEMA 4
- Frequency Rating:
- 60 Hz
- Interrupt Rating:
- 200 kAIC
- Nominal Discharge Current:
- 20 kA
- Operating Temperature:
- -40 to 50 °C
- Operating Voltage:
- 150V L-N, 300V L-L
- Phase:
- Single-phase
- Product Height:
- 2.5 in
- Product Length Depth:
- 7 in
- Product Type:
- Surge Protection Device
- Product Weight:
- 1 lb
- Product Width:
- 5 in
- Protection:
- 600V L-N, 1000V L-L, 800V N-G, 600V L-G
- Short Circuit Rating:
- 22000 kA
- Special Features:
- Meets or exceeds the requirments specified in IBC ®2006, CBC2007, and UBC®Zone 4
- Surge Current:
- 108 kA
- Voltage Rating:
- 120/240 V
- Product Group:
- Electrical
- Department:
- Electrical