Mersen Class J Time-Delay Fuse 200A 600VAC/500VDC with SmartSpot Indication System
Professional Circuit Protection with Advanced Fault Indication Technology
The Mersen Class J Time-Delay Fuse delivers reliable circuit protection with 200A ampere rating and dual voltage capability of 600VAC/500VDC. Featuring SmartSpot indication system for visual fault status, GMG body insulating material for durability, and brass connection terminals with blade-type design for secure installation. This Amp-Trap 2000 series fuse provides 200 kA breaking capacity with clip or bolted mounting flexibility for professional electrical applications.
Professional Features & Benefits
- 200A Ampere Rating: Provides robust current-carrying capacity for high-demand electrical circuits and equipment protection.
- 600VAC/500VDC Dual Voltage: Versatile voltage compatibility supports both AC and DC applications across diverse electrical systems.
- SmartSpot Indication System: Visual fault indication technology enables quick status assessment and reduces troubleshooting time.
- 200 kA Breaking Capacity: High interrupting rating ensures reliable fault current interruption under extreme conditions.
- Class J Time-Delay Characteristic: Allows temporary overloads while providing fast response to fault conditions for optimal equipment protection.
- GMG Body Construction: Advanced insulating material provides superior electrical isolation and mechanical durability.
- Brass Blade Terminals: Corrosion-resistant connection terminals ensure reliable electrical contact and long-term performance.
Technical Specifications
- Ac Max I R Breaking Capacity I1: 200 kA
- Ac Or Dc: AC/DC
- Ampere Rating: 200 A
- Body Insulating Material: GMG
- Connection Terminal Material: Brass
- Connection Terminal Type: Blade
- Frequency Hz : 50/60 Hz
- Fuse Class: Class J
- Indication System: Yes
- Indication System Type: SmartSpot�
- Mounting Method: Clip or Bolted
- Product Length: 5.75 in
- Product Weight: 0.764 lb
- Rated Voltage Ac Ul: 600 V
- Rated Voltage Dc Ul: 500 V
- Rohs Compliant: Yes
- Speed Characteristic: Time Delay
Installation & Operation
- Mount the unit in a suitable location with appropriate clearance and access for connections and service.
- Connect utility and load conductors following applicable guidelines and the manufacturer's instructions.
- Wire generator or power input according to the provided voltage/phase specifications and compatible capacity.
- Configure any available load management or control features as supported by the provided specifications.
- Test automatic transfer or operational functionality and verify proper performance before placing into service.
- Complete final inspection and follow ongoing maintenance practices appropriate to the product category.
Professional Applications
- Industrial Motor Control Centers and Distribution Panels
- Commercial Building Electrical Systems
- Manufacturing Equipment Protection
- Power Distribution Switchgear
- HVAC System Circuit Protection
- Emergency Power Systems
- Critical Infrastructure Facilities
Why Choose Mersen Quality?
Mersen delivers proven reliability through advanced GMG insulating materials, precision-engineered brass terminals, and innovative SmartSpot indication technology. RoHS compliant construction ensures environmental responsibility while maintaining the high performance standards required for professional electrical protection applications.
Manufacturer Resources
Product Specs
- Ac Max I R Breaking Capacity I1:
- 200 kA
- Ac Or Dc:
- AC/DC
- Ampere Rating:
- 200 A
- Body Insulating Material:
- GMG
- Connection Terminal Material:
- Brass
- Connection Terminal Type:
- Blade
- Frequency Hz :
- 50/60 Hz
- Fuse Class:
- Class J
- Indication System:
- Yes
- Indication System Type:
- SmartSpot®
- Mounting Method:
- Clip or Bolted
- Product Length:
- 5.75 in
- Product Weight:
- 0.764 lb
- Rated Voltage Ac Ul:
- 600 V
- Rated Voltage Dc Ul:
- 500 V
- Rohs Compliant:
- Yes
- Speed Characteristic:
- Time Delay