Mersen AJT300 Class J Time-Delay Fuse 300A 600VAC/500VDC with SmartSpot Indication
Professional Class J Time-Delay Protection with Advanced Indication Technology
The Mersen AJT300 Class J Time-Delay Fuse delivers reliable overcurrent protection with 300A rating for both AC and DC applications. Featuring 600VAC/500VDC dual voltage capability and SmartSpot indication system, this blade-type fuse provides professional-grade protection with visual status monitoring. The GMG insulating material body and brass connection terminals ensure dependable performance in demanding electrical environments.
Professional Features & Benefits
- 300A Current Rating: Handles substantial electrical loads while providing precise overcurrent protection for critical circuits and equipment.
- Class J Time-Delay Design: Allows temporary overloads while quickly clearing dangerous fault conditions, protecting motors and other inductive loads.
- Dual Voltage Capability: 600VAC/500VDC rating provides versatility for both AC and DC applications in industrial and commercial systems.
- SmartSpot Indication System: Visual indication technology shows fuse status at a glance, reducing troubleshooting time and improving maintenance efficiency.
- 200kA Breaking Capacity: High interrupting rating safely clears severe fault currents, protecting downstream equipment and personnel.
- Blade Terminal Design: Brass blade terminals with clip or bolted mounting provide secure connections and flexible installation options.
- GMG Insulating Material: Advanced body material ensures reliable insulation and mechanical strength in demanding environments.
Technical Specifications
- Ac Max I R Breaking Capacity I1: 200 kA
- Ac Or Dc: AC/DC
- Ampere Rating: 300 A
- Body Insulating Material: GMG
- Connection Terminal Material: Brass
- Connection Terminal Type: Blade
- Frequency Hz : 50/60 Hz
- Fuse Class: Class J
- Indication System: Yes
- Indication System Type: SmartSpot�
- Mounting Method: Clip or Bolted
- Product Length: 7.13 in
- Product Weight: 1.79 lb
- Rated Voltage Ac Ul: 600 V
- Rated Voltage Dc Ul: 500 V
- Rohs Compliant: Yes
- Speed Characteristic: Time Delay
Installation & Operation
- Mount the unit in a suitable location with appropriate clearance and access for connections and service.
- Connect utility and load conductors following applicable guidelines and the manufacturer's instructions.
- Wire generator or power input according to the provided voltage/phase specifications and compatible capacity.
- Configure any available load management or control features as supported by the provided specifications.
- Test automatic transfer or operational functionality and verify proper performance before placing into service.
- Complete final inspection and follow ongoing maintenance practices appropriate to the product category.
Professional Applications
- Industrial Motor Control Centers and Distribution Panels
- Commercial HVAC and Lighting Systems
- Manufacturing Equipment Protection
- Data Center and Telecommunications Infrastructure
- Healthcare and Critical Facility Power Systems
- Renewable Energy and Battery Storage Systems
- Marine and Transportation Applications
Why Choose Mersen Quality?
Mersen delivers proven reliability with RoHS compliant construction and professional-grade materials. The SmartSpot indication system and robust GMG insulating material demonstrate Mersen's commitment to advanced protection technology and long-term performance in critical electrical applications.
Manufacturer Resources
Product Specs
- Ac Max I R Breaking Capacity I1:
- 200 kA
- Ac Or Dc:
- AC/DC
- Ampere Rating:
- 300 A
- Body Insulating Material:
- GMG
- Connection Terminal Material:
- Brass
- Connection Terminal Type:
- Blade
- Frequency Hz :
- 50/60 Hz
- Fuse Class:
- Class J
- Indication System:
- Yes
- Indication System Type:
- SmartSpot®
- Mounting Method:
- Clip or Bolted
- Product Length:
- 7.13 in
- Product Weight:
- 1.79 lb
- Rated Voltage Ac Ul:
- 600 V
- Rated Voltage Dc Ul:
- 500 V
- Rohs Compliant:
- Yes
- Speed Characteristic:
- Time Delay