Mersen TR15R Class RK5 Time-Delay Fuse 15A 250VAC/160VDC Ferrule Terminal
Professional Time-Delay Circuit Protection with High Breaking Capacity
The Mersen TR15R delivers reliable Class RK5 time-delay fuse protection with 15A rating for both AC and DC applications. Engineered with 250VAC/160VDC voltage capability and 200kA breaking capacity, this ferrule terminal fuse provides professional-grade overcurrent protection with PolyTube insulation and copper connection terminals for dependable performance in diverse electrical systems.
Professional Features & Benefits
- 15A Current Rating: Provides precise overcurrent protection for medium-load circuits and equipment applications.
- Class RK5 Time-Delay: Allows temporary overloads while protecting against sustained overcurrent conditions for motor and inductive load compatibility.
- 200kA Breaking Capacity: Delivers exceptional fault current interruption capability for high-demand electrical systems and industrial applications.
- Dual Voltage Rating (250VAC/160VDC): Supports both AC and DC applications with appropriate voltage specifications for versatile installation requirements.
- Ferrule Terminal Design: Ensures secure connection and reliable contact with copper terminal material for consistent electrical performance.
- PolyTube Body Construction: Provides durable insulation and mechanical protection with lightweight 0.037 lb design for easy handling.
- RoHS Compliant: Meets environmental compliance standards for professional electrical installations and regulatory requirements.
Technical Specifications
- Ac Max I R Breaking Capacity I1: 200 kA
- Ac Or Dc: AC/DC
- Ampere Rating: 15 A
- Body Insulating Material: PolyTube
- Connection Terminal Material: Copper
- Connection Terminal Type: Ferrule
- Frequency Hz : 50/60 Hz
- Fuse Class: Class RK5
- Mounting Method: Clip
- Product Length: 2 in
- Product Weight: 0.037 lb
- Rated Voltage Ac Ul: 250 V
- Rated Voltage Dc Ul: 160 V
- Rohs Compliant: Yes
- Speed Characteristic: Time Delay
Installation & Operation
- Mount the unit in a suitable location with appropriate clearance and access for connections and service.
- Connect utility and load conductors following applicable guidelines and the manufacturer's instructions.
- Wire generator or power input according to the provided voltage/phase specifications and compatible capacity.
- Configure any available load management or control features as supported by the provided specifications.
- Test automatic transfer or operational functionality and verify proper performance before placing into service.
- Complete final inspection and follow ongoing maintenance practices appropriate to the product category.
Professional Applications
- Motor Control Centers and Industrial Equipment Protection
- Commercial HVAC and Lighting Circuit Protection
- Power Distribution Panels and Switchgear Applications
- DC Power Systems and Battery Backup Circuits
- Process Control and Automation Equipment
- Electrical Maintenance and Replacement Projects
- Professional Electrical Contractor Installations
Why Choose Mersen Quality?
Mersen delivers proven reliability in circuit protection with RoHS compliant construction and professional-grade materials. The TR15R fuse combines time-delay characteristics with high breaking capacity and dual voltage capability, ensuring dependable overcurrent protection for demanding electrical applications with consistent performance and regulatory compliance.
Manufacturer Resources
Product Specs
- Ac Max I R Breaking Capacity I1:
- 200 kA
- Ac Or Dc:
- AC/DC
- Ampere Rating:
- 15 A
- Body Insulating Material:
- PolyTube
- Connection Terminal Material:
- Copper
- Connection Terminal Type:
- Ferrule
- Frequency Hz :
- 50/60 Hz
- Fuse Class:
- Class RK5
- Mounting Method:
- Clip
- Product Length:
- 2 in
- Product Weight:
- 0.037 lb
- Rated Voltage Ac Ul:
- 250 V
- Rated Voltage Dc Ul:
- 160 V
- Rohs Compliant:
- Yes
- Speed Characteristic:
- Time Delay