Mersen TR80R Class RK5 Time-Delay Fuse 250VAC/250VDC 80A Blade Terminal
Professional Time-Delay Protection with High Breaking Capacity
The Mersen TR80R delivers reliable Class RK5 time-delay fuse protection with 80A rating and dual voltage capability at 250VAC/250VDC. Featuring blade terminal connections with tin-plated copper construction and PolyTube insulating material, this Tri-Onic fuse provides professional-grade overcurrent protection with 200 kA breaking capacity for demanding electrical applications.
Professional Features & Benefits
- 80A Ampere Rating: Provides robust overcurrent protection for medium-duty electrical circuits and equipment applications.
- Class RK5 Time-Delay: Delivers selective coordination and allows temporary overloads while protecting against sustained overcurrent conditions.
- 250VAC/250VDC Dual Rating: Offers versatile protection for both AC and DC electrical systems with consistent performance.
- 200 kA Breaking Capacity: Ensures reliable interruption of high fault currents for enhanced system safety and protection.
- Blade Terminal Design: Facilitates secure clip mounting with tin-plated copper terminals for reliable electrical connections.
- PolyTube Construction: Provides durable insulating material that maintains performance integrity in professional environments.
- RoHS Compliant: Meets environmental compliance standards for responsible electrical component selection.
Technical Specifications
- Ac Max I R Breaking Capacity I1: 200 kA
- Ac Or Dc: AC/DC
- Ampere Rating: 80 A
- Body Insulating Material: PolyTube
- Connection Terminal Material: Tin-Plated Copper
- Connection Terminal Type: Blade
- Frequency Hz : 50/60 Hz
- Fuse Class: Class RK5
- Mounting Method: Clip
- Product Length: 5.88 in
- Product Weight: 0.303 lb
- Rated Voltage Ac Ul: 250 V
- Rated Voltage Dc Ul: 250 V
- Rohs Compliant: Yes
- Speed Characteristic: Time Delay
Installation & Operation
- Mount the fuse in a suitable fuse holder or disconnect with appropriate clearance and access for connections and service.
- Connect utility and load conductors following applicable guidelines and the manufacturer's instructions.
- Wire generator or power input according to the provided voltage/phase specifications and compatible capacity.
- Configure any available load management or control features as supported by the provided specifications.
- Test automatic transfer or operational functionality and verify proper performance before placing into service.
- Complete final inspection and follow ongoing maintenance practices appropriate to the product category.
Professional Applications
- Industrial Motor Control Centers
- Commercial Electrical Panels
- HVAC Equipment Protection
- Manufacturing Process Equipment
- Power Distribution Systems
- Electrical Maintenance and Repair
- Professional Electrical Installations
Why Choose Mersen Quality?
Mersen delivers proven reliability with RoHS compliant construction and professional-grade materials including tin-plated copper terminals and PolyTube insulation. The 200 kA breaking capacity and Class RK5 time-delay characteristics ensure dependable overcurrent protection for critical electrical systems and equipment applications.
Manufacturer Resources
Product Specs
- Ac Max I R Breaking Capacity I1:
- 200 kA
- Ac Or Dc:
- AC/DC
- Ampere Rating:
- 80 A
- Body Insulating Material:
- PolyTube
- Connection Terminal Material:
- Tin-Plated Copper
- Connection Terminal Type:
- Blade
- Frequency Hz :
- 50/60 Hz
- Fuse Class:
- Class RK5
- Mounting Method:
- Clip
- Product Length:
- 5.88 in
- Product Weight:
- 0.303 lb
- Rated Voltage Ac Ul:
- 250 V
- Rated Voltage Dc Ul:
- 250 V
- Rohs Compliant:
- Yes
- Speed Characteristic:
- Time Delay