Mersen TRS80R Class RK5 Time-Delay Fuse 80A 600VAC/600VDC Blade Terminal Tri-Onic
Professional Class RK5 Time-Delay Protection for Critical Electrical Systems
The Mersen TRS80R delivers reliable overcurrent protection with 80A capacity and dual-voltage compatibility at 600VAC/600VDC. This Class RK5 time-delay fuse features Tri-Onic technology with blade terminal connections and PolyTube insulating material for dependable performance in demanding electrical applications. The tin-plated copper terminals ensure secure connections while the clip mounting method provides convenient installation.
Professional Features & Benefits
- 80A Current Rating: Provides robust overcurrent protection for medium-duty electrical circuits and equipment loads.
- 600VAC/600VDC Dual Voltage: Versatile compatibility supports both AC and DC applications with consistent protection performance.
- Class RK5 Time-Delay: Allows temporary overloads while providing fast clearing of fault conditions to protect downstream equipment.
- 200 kA Breaking Capacity: High interrupting rating ensures reliable fault current interruption in demanding electrical environments.
- Blade Terminal Design: Tin-plated copper terminals with clip mounting enable secure connections and straightforward installation.
- PolyTube Insulation: Durable insulating material provides reliable electrical isolation and mechanical protection.
- Tri-Onic Technology: Advanced fuse element design delivers consistent performance and reliable protection characteristics.
Technical Specifications
- Ac Max I R Breaking Capacity I1: 200 kA
- Ac Or Dc: AC/DC
- Ampere Rating: 80 A
- Body Insulating Material: PolyTube
- Connection Terminal Material: Tin-Plated Copper
- Connection Terminal Type: Blade
- Frequency Hz : 50/60 Hz
- Fuse Class: Class RK5
- Mounting Method: Clip
- Product Length: 7.88 in
- Product Weight: 0.628 lb
- Rated Voltage Ac Ul: 600 V
- Rated Voltage Dc Ul: 600 V
- Speed Characteristic: Time Delay
Installation & Operation
- Mount the unit in a suitable location with appropriate clearance and access for connections and service.
- Connect utility and load conductors following applicable guidelines and the manufacturer's instructions.
- Wire generator or power input according to the provided voltage/phase specifications and compatible capacity.
- Configure any available load management or control features as supported by the provided specifications.
- Test automatic transfer or operational functionality and verify proper performance before placing into service.
- Complete final inspection and follow ongoing maintenance practices appropriate to the product category.
Professional Applications
- Industrial Motor Control Centers and Distribution Panels
- Commercial HVAC and Lighting Control Systems
- Manufacturing Equipment and Process Control Applications
- Data Centers and Critical Power Distribution
- Healthcare Facilities and Emergency Power Systems
- Educational and Institutional Electrical Infrastructure
- Renewable Energy and Battery Storage Systems
Why Choose Mersen Quality?
Mersen fuses deliver proven reliability with Class RK5 time-delay characteristics and 200 kA breaking capacity for demanding electrical protection applications. The PolyTube insulation and tin-plated copper terminals ensure long-term performance and dependable connections in professional electrical installations.
Manufacturer Resources
Product Specs
- Ac Max I R Breaking Capacity I1:
- 200 kA
- Ac Or Dc:
- AC/DC
- Ampere Rating:
- 80 A
- Body Insulating Material:
- PolyTube
- Connection Terminal Material:
- Tin-Plated Copper
- Connection Terminal Type:
- Blade
- Frequency Hz :
- 50/60 Hz
- Fuse Class:
- Class RK5
- Mounting Method:
- Clip
- Product Length:
- 7.88 in
- Product Weight:
- 0.628 lb
- Rated Voltage Ac Ul:
- 600 V
- Rated Voltage Dc Ul:
- 600 V
- Speed Characteristic:
- Time Delay