LCN 7982ES Dual Door Pneumatic...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$8,502.53
$6,192.13

LCN 7982ES Dual Door Pneumatic Control Box with Electric Strike Relay

(No reviews yet) Write a Review

Model: 7982ES

In Stock (leaves warehouse same day if ordered before 3pm ET)

$8,502.53
$6,192.13
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

LCN 7982ES Dual Door Pneumatic Control Box with Electric Strike Relay

Professional Two-Door Pneumatic Control Solution

The LCN 7982ES from the 7900 Series provides comprehensive pneumatic control for two door applications with integrated electric strike relay functionality. This self-contained control box and compressor combination enables independent or simultaneous operation of two door leaves through dual pneumatic circuits. The system accepts normally open (N.O.) inputs from both hardwired and RF wireless actuator/receiver combinations, offering flexible installation options for commercial access control applications.

Professional Features & Benefits

  • Dual Door Control: Independent pneumatic circuits allow for separate or simultaneous operation of two door leaves for versatile access management.
  • Self-Contained Design: Integrated control box and compressor combination eliminates the need for separate compressor equipment, simplifying installation and reducing system complexity.
  • Flexible Input Options: Accepts normally open (N.O.) inputs from both hardwired and RF wireless actuator/receiver combinations for adaptable system integration.
  • Electric Strike Integration: Built-in electric strike relay provides coordinated door hardware control for complete access management solutions.
  • Sequential Operation Available: Optional sequential operation (suffix "S") provides controlled door opening sequence for enhanced security protocols.
  • 7900 Series Engineering: Part of LCN's proven 7900 Series pneumatic control platform designed for reliable commercial performance.
  • ADA Compliant Design: Meets accessibility requirements for commercial building applications.

Technical Specifications

  • ADA Compliant: Yes
  • Commercial/Residential: Commercial
  • Department: Door Hardware
  • Electronic: Yes
  • Parts and Accessories Type: Installation Accessories
  • Product Attribute: Parts and Accessories
  • Product Category: Electronic Access Controls
  • Product Group: Electronic Access Controls
  • Product Subgroup: Parts and Accessories
  • Product Type: Safety Packages
  • Series: 7900 Series
  • Subcategory: Closer Parts and Accessories

Professional Applications

  • Commercial Building Access Control Systems
  • Healthcare Facility Security Entrances
  • Educational Institution Safety Systems
  • Retail Store Entry Management
  • Industrial Facility Access Points
  • Government and Municipal Buildings
  • Multi-Tenant Residential Properties

Why Choose LCN Quality?

LCN pneumatic control systems deliver professional-grade reliability with self-contained compressor design that eliminates external equipment dependencies. The 7900 Series platform provides proven performance in demanding commercial applications where dependable two-door coordination and electric strike integration are essential. Engineered for flexible installation with both hardwired and wireless input compatibility for adaptable access control solutions.

Product Specs

Subcategory:
Closer Parts and Accessories
Series:
7900 Series
Product Group:
Electronic Access Controls
Product Subgroup:
Parts and Accessories
Product Type:
Safety Packages
Commercial/Residential:
Commercial
Electronic:
Yes
ADA Compliant:
Yes
Parts and Accessories Type:
Installation Accessories
Product Attribute:
Parts and Accessories
Product Category:
Electronic Access Controls
Department:
Door Hardware

LCN 7982ES – Frequently Asked Questions

1) What does the LCN 7982ES control box actually do in an automatic door system?
The 7982ES is the pneumatic control box and compressor combined in one enclosure, and it runs two door leaves rather than one. Each leaf gets its own pneumatic circuit, so the pair can be opened independently or together off the same box. Because the compressor is built in, there is no separate air source to mount, run tubing from, or find room for above the ceiling. It also carries an electric strike relay, so the box releases the strike and drives the door on the same activation instead of needing a separate relay module in the loop.
2) I only have one automatic door. Is the 7982ES the right control box?
No. The 7982ES is built around two independent pneumatic circuits for two door leaves, so on a single opening you are paying for and wiring a second circuit you will never use. Look at the single-door control box in LCN's 7900 Series pneumatic line instead. Take the dual-door box when you have a pair of leaves, a vestibule with two openings you want sequenced, or a second door you expect to add later.
3) Will the LCN 7982ES work with a wireless push plate, or does it have to be hardwired?
Either. The 7982ES accepts normally open inputs, and it takes them from hardwired actuators and from RF wireless actuator/receiver combinations alike. That matters on a retrofit where you cannot get conduit across a lobby or through a masonry wall, put the receiver at the box and the wireless plates go wherever the traffic is. The one thing to confirm on whatever actuator you pair with it is that the output is dry N.O.; the box is not looking for a normally closed contact.
4) How do I order the LCN 7982ES for a vestibule where the doors need to open one after the other?
Sequential operation is an ordering option on the box, specified with the suffix S. Standard, the two circuits fire together or independently as the actuators call them. With the S option the box controls the order the leaves open, which is what you want in an air-lock vestibule or where an interior leaf should not swing until the exterior one has cleared. Decide it at order time, it is a suffix on the model, not a field setting.
5) Do I need a separate relay to release the electric strike with the LCN 7982ES?
No, the strike relay is built into the 7982ES. The box coordinates releasing the strike with driving the doors, so the latch is free before the leaf is pushed rather than the operator fighting a latched door. You still supply the strike and its power source; what the box removes is the standalone relay module and the extra wiring between it and the control.
6) Is the LCN 7982ES a complete automatic door package, or do I need more parts?
It is the control end of the system, not the whole system. The 7982ES supplies the control logic, the compressed air, and the strike relay for two leaves. You order separately the pneumatic operators on the doors, the actuators (hardwired push plates or wireless plate and receiver), and the electric strikes themselves. Budget the job that way rather than expecting one box to arrive and finish the opening.
7) Does the LCN 7982ES meet ADA requirements for a public building entrance?
ADA compliant, yes, and it is a commercial-rated product rather than a residential one. That covers the control side of the opening. The accessibility of the finished entrance also depends on the operator and the actuators you pair with it and how they are positioned, so the box being compliant is one part of a compliant opening, not the whole of it.
8) Can the two doors on an LCN 7982ES be activated from separate push plates?
Yes. The circuits are independent, so each leaf can have its own actuator and open on its own, or both can be tied to a single activation and open together. That is useful where a pair serves different traffic, say a main leaf on a lobby plate and a second leaf on a card reader output, and equally useful where you want one plate to open the whole pair for a gurney or a cart.
9) Is a pneumatic door control like the LCN 7982ES a good fit for a healthcare or high-traffic entrance?
That is the class of opening the 7900 Series pneumatic platform is built for, commercial rather than residential, and healthcare entrances, schools, retail entries, government buildings and multi-tenant residential are among its typical applications. Pneumatic control suits places where you want touchless or push-plate activation on a pair of doors and a single box handling both leaves. Being ADA compliant, it also fits the accessible entrance requirement those facility types usually carry.
How fast can I get the LCN 7982ES delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the LCN 7982ES come with a warranty?
Absolutely. The LCN 7982ES is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the LCN 7982ES?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the LCN 7982ES from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.