Leviton 8200-IGW Hospital Grad...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$5,099.03

Leviton 8200-IGW Hospital Grade Isolated Ground Duplex Receptacle, 15A-125V, Pack of 100

(No reviews yet) Write a Review

Model: 8200-IGW

In Stock (leaves warehouse same day if ordered before 3pm ET)

$5,099.03
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Leviton 8200-IGW Hospital Grade Isolated Ground Duplex Receptacle, 15A-125V

The Leviton 8200-IGW is a Hospital Grade Isolated Ground Duplex Receptacle rated 15A-125V, engineered for environments where reliable, low-noise power delivery is essential. Featuring a white finish and Leviton's Hospital Grade construction, this duplex receptacle is built to withstand the demands of healthcare, institutional, and commercial electrical systems. The isolated ground (IG) design helps minimize electrical noise interference for connected equipment, making it a dependable choice for professional installers specifying Leviton devices for critical power applications. Whether used in a hospital wing, laboratory, or any facility where clean, stable power is a priority, the 8200-IGW is intended to be a long-term, code-conscious wiring device solution.

Key Features

  • Electrical Rating: Rated 15A at 125V, suitable for standard branch-circuit duplex receptacle applications in commercial and institutional wiring systems.
  • Duplex Configuration: Two-outlet duplex design delivers convenient, space-efficient power access at a single wiring location, reducing the number of devices needed per circuit.
  • Hospital Grade Construction: Built to Hospital Grade performance standards, providing the durability, contact retention, and reliability required in demanding healthcare and heavy-use environments.
  • Isolated Ground (IG) Design: The isolated ground configuration separates the grounding path from the mounting strap to help reduce electrical noise for sensitive connected equipment such as diagnostic or data-sensitive devices.
  • Finish: White housing finish for a clean, professional appearance that integrates with standard wall plates and existing device layouts.
  • Model Identification: Cataloged under the Leviton 8200 series as model 8200-IGW, combining Hospital Grade (HG), Isolated Ground (IG), and white finish (W) attributes in a single duplex device.

Technical Specifications

  • Refer to manufacturer documentation for complete technical specifications.

Typical Applications

  • Hospital and Healthcare Facility Wiring
  • Isolated Ground Circuits for Sensitive Electronic Equipment
  • Commercial and Institutional Buildings
  • Patient Care Areas Requiring Hospital Grade Devices
  • Laboratories and Data-Sensitive Environments
  • Renovation and New Construction Electrical Projects

Why Leviton?

Leviton is a trusted name in professional electrical devices, and the 8200-IGW reflects that standard with Hospital Grade construction and an isolated ground design built for demanding, code-conscious installations. For electricians, contractors, and facility managers who need dependable 15A-125V duplex receptacles for healthcare and sensitive-equipment environments, the Leviton 8200-IGW is designed to deliver consistent, reliable performance backed by Leviton's reputation for quality electrical products and long-standing presence in the professional wiring device market.

Manufacturer Resources

Product Specs

Department:
Electrical
Product Subgroup:
Receptacles & Outlets
Product Type:
Duplex Receptacle
Pack size (unit):
100
Product Group:
Wiring Devices

Leviton 8200-IGW – Frequently Asked Questions

1) What is the Leviton 8200-IGW receptacle rated for, and where is it used?
The 8200-IGW is a hospital grade duplex receptacle rated 15A at 125V, white, with an isolated ground configuration. It's used on standard branch circuits in patient care areas, labs, and other spots where sensitive electronics need a quiet ground reference.
2) What does the isolated ground on the 8200-IGW actually change about how I wire it?
The grounding terminal is separated from the mounting strap, so the equipment ground does not bond to the yoke, box, or conduit. That means you need to run a separate insulated grounding conductor back to the panel ground point; the device will not pick up ground through the metal box the way a standard receptacle does. That isolated path is what keeps electrical noise off sensitive diagnostic and data equipment.
3) Can I use a regular 15A receptacle instead of a hospital grade one in a patient care area?
Not interchangeably. Hospital grade devices are built to tighter contact retention and durability requirements, and patient care spaces call for them specifically. The 8200-IGW covers both needs at once: hospital grade construction plus isolated ground. If the circuit does not feed noise-sensitive equipment, a hospital grade device without the isolated ground is the simpler choice, because it avoids running the extra insulated ground conductor.
4) How many receptacles come in a Leviton 8200-IGW order?
It ships as a pack of 100 devices. That quantity suits a healthcare wing rollout or a facility standardizing isolated ground outlets across multiple rooms; if you need two or three for a repair, this is more than the job calls for.
5) Do I need a special wall plate or a different box for a hospital grade isolated ground receptacle?
No. The 8200-IGW is a standard duplex device with a white finish, so it takes ordinary duplex wall plates and drops into existing device layouts. What changes is the wiring, not the plate or the opening: you still need the separate insulated ground conductor the isolated ground design requires.
6) What is the exact Leviton part number to order for a white 15A hospital grade isolated ground duplex?
Leviton 8200-IGW. The suffix reads as hospital grade with isolated ground in white, within the Leviton 8200 series. Specify that full number on the order, since the series also covers other finish and ground configurations.
7) Will the 8200-IGW work on a 20A circuit?
The device itself is rated 15A at 125V, so it can be fed by a 20A branch circuit only where the code allows a 15A receptacle on that circuit (multiple-receptacle branch circuits). If the drawing calls for a 20A receptacle face at that location, this is not the right device and you want the 20A hospital grade isolated ground version instead.
How fast can I get the Leviton 8200-IGW delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Leviton 8200-IGW come with a warranty?
Absolutely. The Leviton 8200-IGW is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Leviton 8200-IGW?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Leviton 8200-IGW from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.