Mersen Amp-Trap 2000 A6D-R Class RK1 Time-Delay Ferrule Fuse
Mersen Amp-Trap 2000® A6D-R time-delay fuses are Class RK1 ferrule-terminal fuses rated 600V that deliver IEC Type 2 "no damage" protection to mains, feeders, and branch circuits serving both motor and non-motor loads. Built with a PolyTube body and tin-plated copper terminals for clip mounting, these fuses open fast under extreme fault conditions for maximum short-circuit protection while still providing the time-delay characteristic needed to ride through motor in-rush currents. A6D-R fuses are a direct replacement for older 600V Class H, K, or RK5 fuses already installed in the field.
Key Features
- Fuse Class: Class RK1 construction for IEC Type 2 "no damage" short-circuit protection.
- Speed/Characteristic: Time-Delay operation rides through motor in-rush without nuisance opening.
- Connection/Terminal Type: Ferrule terminals with tin-plated copper for reliable clip mounting.
- Durable Construction: PolyTube body/insulating material for long service life.
- AC Max I.R./Breaking Capacity: 200 kA interrupting rating for demanding fault-current environments.
- Rated Voltage: 600 V DC (UL) for use across 50/60 Hz systems.
- Mounting: Clip mounting for standard fuse holders and disconnect blocks.
Certifications & Compliance
- RoHS Compliant
Technical Specifications
- Connection/Terminal Type: Ferrule
- Mounting: Clip
- Connection/Terminal Material: Tin-Plated Copper
- AC Max I.R./Breaking Capacity: I1: 200 kA
- ROHS Compliant: Yes
- Frequency (Hz): 50/60 Hz
- Speed/Characteristic: Time Delay
- Rated voltage DC UL: 600 V
- Fuse Class: Class RK1
- Body/Insulating Material: PolyTube
Typical Applications
- Existing Mains, Feeders, and Branch Circuits
- Motor and Non-Motor Load Protection
- Replacement for Older 600V Class H, K, or RK5 Fuses
- Motor Starters, Switches, and Circuit Component Protection
- Commercial and Industrial Electrical Panels
Why Mersen?
Mersen Amp-Trap 2000® A6D-R fuses combine a rugged PolyTube body, tin-plated copper ferrule terminals, and a 200 kA interrupting rating to deliver IEC Type 2 "no damage" performance where existing equipment can't be damaged during a fault. The RoHS-compliant, Class RK1 time-delay design gives professionals a dependable, code-compliant upgrade path from legacy Class H, K, and RK5 fuses without reworking existing fuse holders.
Manufacturer Resources
Product Specs
- Connection/Terminal Type:
- Ferrule
- Mounting:
- Clip
- Connection/Terminal Material:
- Tin-Plated Copper
- AC Max I.R./Breaking Capacity: I1:
- 200 kA
- ROHS Compliant:
- Yes
- Frequency (Hz):
- 50/60 Hz
- Speed/Characteristic:
- Time Delay
- Rated voltage DC UL:
- 600 V
- Fuse Class:
- Class RK1
- Body/Insulating Material:
- PolyTube
- list_batch:
- MERSEN-20260825
- Department:
- Electrical
- Product Group:
- Wiring Devices
- Product Type:
- Fuse