The Mersen Amp-Trap AG Series is a complete line of UL Listed Class G fuses featuring time-delay protection (above 5A rating) for branch-circuit applications. This family is available across a range of amp ratings from 6A through 50A, covering four physical fuse sizes to match the required current level. Every AG Series fuse uses ferrule-style construction with clip mounting and tin-plated copper terminals for durable, corrosion-resistant connections. With a 100 kA AC maximum interrupting rating and RoHS-compliant GMG body construction, the Amp-Trap AG series delivers reliable protection for lighting, heating, and appliance circuits across the full 6A-50A range.
Key Features
- Amp Rating Range: Available in ratings from 6A up to 50A, allowing selection of the exact fuse for your branch-circuit load.
- Class G Design: UL Listed Class G fuses manufactured in four physical sizes for precise branch-circuit coordination across the amp rating range.
- Time-Delay Protection: Time-delay characteristic (above 5A rating) rides through momentary inrush current without nuisance blowing.
- Ferrule Terminals: Ferrule connection/terminal type paired with clip mounting for straightforward installation and removal across all amp ratings in the series.
- Tin-Plated Copper Terminals: Tin-plated copper terminal material provides a corrosion-resistant, dependable connection point.
- High Interrupt Rating: 100 kA AC maximum interrupting/breaking capacity (I1) supports use in demanding fault-current environments regardless of the amp rating selected.
- AC Rated, 50/60 Hz: Engineered for AC circuits operating at 50/60 Hz across the entire 6A-50A range.
- GMG Body Material: GMG body/insulating material construction that is RoHS compliant.
Certifications & Compliance
- UL Listed
- RoHS Compliant
Technical Specifications
- Amp Rating Range: 6A - 50A
- ROHS Compliant: Yes
- AC or DC: AC
- Body/Insulating Material: GMG
Typical Applications
- Lighting Circuit Branch-Circuit Protection
- Heating Circuit Protection
- Appliance Circuit Protection
- Commercial and Industrial Electrical Panels
- Panelboard and Load Center Fuse Replacement
Why Mersen?
Mersen's Amp-Trap AG series combines UL Listed Class G construction, tin-plated copper ferrule terminals, and a 100 kA AC interrupting rating to deliver dependable, code-compliant circuit protection across its full 6A-50A amp rating range. RoHS-compliant GMG body materials and time-delay performance make these fuses a trusted choice for professional electrical installations requiring reliable branch-circuit fusing, whatever amp rating the application calls for.
Manufacturer Resources
Product Specs
- Connection/Terminal Type:
- Ferrule
- Mounting Method:
- Clip
- Connection/Terminal Material:
- Tin-Plated Copper
- AC Max I.R./Breaking Capacity: I1:
- 100 kA
- ROHS Compliant:
- Yes
- Frequency (Hz):
- 50/60 Hz
- Speed/Characteristic:
- Time Delay
- AC or DC:
- AC
- Fuse Class:
- Class G
- Body/Insulating Material:
- GMG
- list_batch:
- MERSEN-20260825
- Department:
- Electrical
- Product Group:
- Wiring Devices
- Product Type:
- Fuse
- Configuration:
- Class G Time-Delay Ferrule
- Amperage Rating:
- 6A - 50A
- Finish:
- Tin-Plated Copper
- Listing:
- UL Listed
- Standards:
- RoHS