Norton Rixson 1028W 5800 Serie...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$692.84
$455.78

Norton Rixson 1028W 5800 Series Wireless Interface Module for Electronic Door Closers

(No reviews yet) Write a Review

Model: 1028W

In Stock (leaves warehouse same day if ordered before 3pm ET)

$692.84
$455.78
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Norton Rixson 1028W 5800 Series Wireless Interface Module for Electronic Door Closers

Professional Wireless Access Control Integration Solution

The Norton Rixson 1028W 5800 Series Wireless Interface Module is a high-performance access control module designed to integrate Norton Rixson 5800 Series electronic door closers with wireless access control systems. This compact interface module enables seamless communication between door hardware and networked systems, allowing for remote management of user access and door operations. Constructed with high-strength, durable plastic housing, the module is powered by the door closer or external power supply for flexible installation options.

Professional Features & Benefits

  • 5800 Series Compatibility: Specifically designed for Norton Rixson 5800 Series electronic door closers for seamless integration and optimal performance.
  • Wireless Communication Technology: Eliminates the need for hardwired connections while providing secure communication with networked access control systems.
  • Remote Access Management: Enables remote configuration and real-time monitoring of door operation and user access for centralized security control.
  • Compact Space-Efficient Design: Small module design allows easy installation in tight spaces and compatibility with a wide range of door systems.
  • Flexible Power Options: Powered by door closer or external power supply to accommodate various installation requirements and system configurations.
  • Durable Construction: High-strength, durable plastic housing provides long-term reliability in demanding commercial and institutional environments.
  • Low-Maintenance Operation: Designed for minimal maintenance requirements, providing long-term reliability and performance with simple setup and operation.

Technical Specifications

  • Commercial/Residential: Commercial
  • Compatibilty: All Low Energy Operators Except 5800
  • Department: Door Hardware
  • Electronic: Yes
  • Product Category: Electronic Access Controls
  • Product Group: Electronic Access Controls
  • Product Subgroup: Sensors, Switches, Relays and Timers
  • Product Type: Push Plates
  • Subcategory: Accessories

Installation & Operation

  1. Verify electrical requirements match available power supply from door closer or external source before proceeding with installation.
  2. Disconnect power supply before beginning installation. Follow all applicable electrical codes and safety procedures.
  3. Mount the wireless interface module in the specified location ensuring adequate clearance for wireless signal transmission and future service access.
  4. Route and connect wiring according to manufacturer wiring diagrams for integration with Norton Rixson 5800 Series door closers.
  5. Configure wireless communication settings and network integration parameters per application requirements and access control system specifications.
  6. Restore power and test all functions including wireless communication, door closer integration, and network connectivity with the access control system.
  7. Complete final inspection and document network settings. Refer to manufacturer documentation for complete wiring diagrams, programming instructions, and troubleshooting.

Professional Applications

  • Commercial Building Security Systems
  • Educational Institution Access Control
  • Healthcare Facility Security Networks
  • Government and Municipal Buildings
  • Corporate Office Access Management
  • Industrial Facility Entry Control
  • Multi-Tenant Commercial Properties

Why Choose Norton Rixson Quality?

Norton Rixson wireless interface modules deliver professional-grade reliability with high-strength, durable plastic housing designed for demanding commercial and institutional applications. The low-maintenance design ensures long-term performance with minimal service requirements. Engineered for seamless integration with Norton Rixson 5800 Series door closers where dependable wireless access control communication is essential.

Manufacturer Resources

Product Specs

Product Group:
Electronic Access Controls
Product Subgroup:
Sensors, Switches, Relays and Timers
Product Type:
Push Plates
Subcategory:
Accessories
Commercial/Residential:
Commercial
Electronic:
Yes
Compatibility:
All Low Energy Operators Except 5800
Product Category:
Electronic Access Controls
Department:
Door Hardware

Norton Rixson 1028W – Frequently Asked Questions

1) Is the Norton Rixson 1028W a wall push plate or actuator button for a door operator?
It isn't a push plate. The 1028W is a wireless interface module, an electronic device that links door hardware to a networked access control system for remote configuration and monitoring. If what you need is the thing people press on the wall to open the door, look at an actuator instead: the SDC 480 Series push plate actuators in 18 gauge stainless, the Camden CM-40 4-1/2 inch round switch, or the Locknetics PPH-100-PL large round push plate with box. For a vestibule with two doors, the SDC 480V Series uses dual switch activation.
2) How is the Norton Rixson 1028W wireless interface module powered? Do I need to run a separate power supply?
Two options, and that is the point of the flexible power design: the module can be powered from the door closer itself or from an external power supply. On an opening where the operator already has power available at the header, you can avoid pulling a dedicated supply. Verify the electrical requirements against the power you actually have at the door before you mount anything, and kill power before wiring.
3) Can I add access control monitoring to an existing opening without running new wire through the frame?
That is what the 1028W is for. It communicates wirelessly with networked access control systems, so you skip the hardwired run between the door hardware and the head end, which matters on retrofits where the frame is already closed up and fishing wire means cutting finishes. You still need power at the module, either from the closer or an external supply. Mount it where the wireless signal has clearance and where you can get back to it for service.
4) Is the Norton Rixson 1028W wireless interface module the same thing as a wireless push plate actuator?
No. The 1028W is a wireless interface module that links a door closer to a networked access control system for remote configuration and monitoring of door operation and user access. A wireless actuator such as the Camden CM-60 is a 6 inch round all-active switch offered wired or with a kinetic wireless transmitter, which is what a person presses to call the door open. The 1028W does not give the user something to press, and the CM-60 does not give the access control system a communication path to the closer, so on a low energy opening that needs both remote management and a knowing act by the user, the two are ordered together rather than one instead of the other.
5) What do I use instead of the 1028W if the goal is simply to open the door from a wall button without a network?
A push plate actuator covers that opening on its own. The SDC 480 Series push plate actuators are built in 18 gauge stainless steel, and the Camden CM-40 is a 4-1/2 inch round all-active switch for a smaller plate footprint. Either one activates the operator directly. The Norton Rixson 1028W is the wireless interface module that carries communication between the door hardware and a networked access control system, so it belongs on jobs where a central system needs to manage and monitor the opening, not on a standalone actuation job.
6) Are there different versions or options to specify when ordering the Norton Rixson 1028W?
No options to pick. The 1028W ships as a single configuration of the wireless interface module, so there is no finish, handing, or voltage variant to call out on the order. What you do need to sort out on site is the power source (closer or external supply) and your network settings, which get configured during commissioning per the access control system you are tying into.
7) I want wireless door activation without wiring a button. Is the 1028W the right part for that?
Not quite, and the distinction matters on a bid. The 1028W handles wireless communication between door hardware and an access control network, not wireless activation from a wall switch. If you want a push plate that transmits without wire, the Camden CM-60 Series 6 inch round switch is offered wired or with a kinetic wireless transmitter. Facilities that need a no-touch approach at an exterior lane often pair an actuator with the SDC BP Series square bollard post, 6 x 6 inch, in a BPS6 42 inch surface mount or BPG6 54 inch in-ground version.
8) For an exterior approach with no wall to mount to, what pairs with the 1028W?
A bollard carries the actuator where there is no adjacent wall. The SDC BP Series square bollard posts are 6 inch by 6 inch, offered as the BPS6 surface mount at 42 inches and the BPG6 in-ground at 54 inches. That is the mounting and actuation side of the opening. The Norton Rixson 1028W is the wireless interface module that ties the door hardware into the access control network, and its compact housing is meant to install in tight spaces at the door, so the bollard and the module do separate jobs on the same entrance.
9) We need a delay on the door before it recloses. Will the 1028W give me that?
No. Timing at the actuator comes from a pneumatic time delay device: the Alarm Controls JP Series is a pneumatic time delay jumbo push plate, and the Alarm Controls PD Series covers pneumatic time delay in the PD, PN, PS and PT vandal resistant push plates. The Norton Rixson 1028W is a wireless interface module whose role is communication with a networked access control system for remote configuration and monitoring, so a delay requirement is answered by the actuator selection.
10) The opening is a school corridor that gets abused. Which part of the package takes the abuse, the 1028W or the actuator?
The actuator does, and that is where to spend the specification. The Alarm Controls PD Series is a vandal resistant push plate line, and the SDC 480 Series uses 18 gauge stainless steel construction. The Norton Rixson 1028W is a commercial wireless interface module in a high-strength durable plastic housing, and it mounts back at the door hardware rather than out on the wall where hands and carts reach it, which is why its housing material is not the deciding factor on a high traffic corridor.
11) Is the Norton Rixson 1028W module rated for commercial and institutional use, or is it a residential product?
Commercial. Norton Rixson classes the 1028W as a commercial electronic device, with a high strength plastic housing meant to hold up in commercial and institutional service. It is the kind of part that goes on school, hospital, government, and multi-tenant office openings where the doors are tied into a central access control system.
12) Is there an ADA touch surface option that replaces a standard plate on the same opening as the 1028W?
The SDC 480AA Series is a 36 inch by 6 inch Ingress-R.E.X touch panel column for ADA compliant access control, which gives a tall touch surface instead of a small plate so the door can be called from a range of heights. It is an actuation choice. The Norton Rixson 1028W remains the wireless interface module handling communication with the access control system, and its selection does not change based on which touch surface is used at the approach.
13) How does the Locknetics PPH-100-PL differ from the Norton Rixson 1028W?
The Locknetics PPH-100-PL is a large round push plate supplied with a box, in black and aluminum, from the PPH Series. It is the user-facing device and its box is the enclosure it mounts into. The Norton Rixson 1028W is a wireless interface module that connects a door closer to a networked access control system and is powered by the door closer or an external power supply. One is chosen on appearance and mounting at the wall, the other on how the opening reports to and is managed by the security system.
How fast can I get the Norton Rixson 1028W delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Norton Rixson 1028W come with a warranty?
Absolutely. The Norton Rixson 1028W is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Norton Rixson 1028W?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Norton Rixson 1028W from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.