Sargent 60-8270-ALEVER Electro...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$1,980.91
$1,335.71

Sargent 60-8270-ALEVER Electromechanical Fail-Safe Mortise Lock with EcoFlex Technology and A Lever Design

(No reviews yet) Write a Review

Model: 60-8270-24V-LNA-26D-RH
From the 8200 Series Collection
$1,980.91
$1,335.71
Selected Finish is
Selected Rose is
Selected Lever is

In Stock (leaves warehouse same day if ordered before 3pm ET)

$1,980.91
$1,335.71
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Sargent 8200 Series Electromechanical Mortise Lock with EcoFlex Technology and A Lever Design

Industry Benchmark Heavy-Duty Mortise Lock with Advanced Power Management

The Sargent 8200 Series electromechanical mortise lock represents the industry benchmark for maximum security and performance in commercial applications. This fail-safe function lock operates from 12 to 24VDC and features revolutionary EcoFlex technology that reduces power consumption up to 96%. Built with heavy-duty components and tested to 16 million cycles, this Grade 1 mortise lock delivers exceptional reliability with a 2 3/4" backset and 3/4" latchbolt throw for standard 1 3/4" door thickness applications.

Professional Features & Benefits

  • Precision Engineering: 2 3/4" backset depth with 3/4" latchbolt throw designed for 1 3/4" door thickness applications with field-reversible handing.
  • Exceptional Durability: UL tested to 16 million cycles (Verification ID: V584148) for long-term reliability in high-traffic commercial applications.
  • Advanced Power Management: EcoFlex technology reduces power consumption up to 96% while operating from 12 to 24VDC for flexible system integration.
  • Fail-Safe Operation: Electromechanical fail-safe configuration provides secure operation with power loss protection for critical applications.
  • Heavy-Duty Construction: Grade 1 rated components engineered for maximum security and performance in demanding commercial environments.
  • Universal Key System Integration: Compatible with all SARGENT key systems including Degree, Signature, KESO, and XC for comprehensive access control.
  • Fire-Rated Performance: UL 10C positive pressure certified with 3-hour fire rating for critical life safety applications.
  • Manufacturer Warranty: 10-year limited warranty on mechanical components with 2-year coverage on electrical components for added confidence and protection.

Technical Specifications

  • Refer to manufacturer documentation for complete technical specifications.

Installation & Operation

  1. Verify electrical requirements match available power supply. Confirm voltage (12 to 24VDC) and current capacity before proceeding.
  2. Disconnect power supply before beginning installation. Follow all applicable electrical codes and safety procedures.
  3. Mount the unit in the specified location ensuring adequate clearance for wiring access, ventilation, and future service requirements.
  4. Route and connect wiring according to manufacturer wiring diagrams. Use appropriate wire gauge and connectors for the application.
  5. Configure operational settings including fail-safe operation per application requirements.
  6. Restore power and test all functions including normal operation, alarm/alert functions, and integration with connected systems.
  7. Complete final inspection and document settings. Refer to manufacturer documentation for complete wiring diagrams, programming instructions, and troubleshooting.

Professional Applications

  • Commercial Office Buildings
  • Educational Facilities
  • Healthcare Institutions
  • Retail Establishments
  • Industrial and Warehouse Facilities
  • Multi-Tenant Residential Properties
  • Government and Municipal Buildings

Why Choose Sargent Quality?

Sargent 8200 Series mortise locks deliver professional-grade reliability with heavy-duty construction tested to 16 million cycles and comprehensive fire-safety certifications including UL 10C 3-hour rating. The 10-year limited warranty on mechanical components with 2-year electrical coverage provides exceptional long-term value. Engineered for demanding commercial applications where dependable performance and advanced power management are essential.

Product Specs

Series:
8200 Series
Grade:
Grade 1
Keyed Function:
Single Cylinder
Product Group:
Mechanical Locks
Product Subgroup:
Bored Locksets
Subcategory:
Bored Locksets
Keyed:
Yes
Commercial/Residential:
Commercial
Lock Type:
Mortise
Lock Function:
Electromechanical
Product Type:
Mortise Locks
Duty Level:
Heavy Duty
Handle Type:
Lever
Product Attribute:
Mortise Locks
Electronic:
No
Product Function:
Electromechanical
Product Category:
Mechanical Locks
Collection:
8200 Series
Pin Cylinder:
LFIC, Less Core
Department:
Door Hardware

Sargent 60-8270-24V-LNA-26D-RH – Frequently Asked Questions

1) What happens to the Sargent 8270 mortise lock when power is lost?
It unlocks. The 8270 is the fail-safe function in the Sargent 8200 electromechanical line, so cutting power releases the outside lever and the door can be opened from either side. That is what you want on a stair tower or an egress-critical opening tied to a fire alarm. If you need the opposite behavior, where the door stays locked when power drops, a fail-safe lock is the wrong choice and you want a fail-secure (electrically locked) function instead.
2) Will the Sargent 8200 electromechanical mortise lock fit a 1-3/4 inch door with a 2-3/4 inch backset?
Yes, that's exactly what it's built for: 2-3/4 inch backset and 1-3/4 inch door thickness, with a 3/4 inch latchbolt throw. The 3/4 inch throw matches a standard ANSI mortise strike, so it drops into a properly prepped commercial frame. Thicker doors than 1-3/4 inches are outside what this lock is specified for.
3) Do I have to order the Sargent 8270 handed, or can I flip it in the field?
Handing is field reversible on the lock body, so you can correct it on site. You still pick LH or RH when ordering because the trim is supplied for a hand. Both left hand and right hand are offered in each rose and voltage combination.
4) What voltage power supply do I need for this Sargent electromechanical mortise lock?
It runs on 12 to 24VDC, and you order it as either a 12V or a 24V unit. EcoFlex power management cuts current draw by up to 96 percent, which matters when you are running several locks off one supply or through a wireless access control panel with a limited current budget.
5) Does the Sargent 8270 mortise lock come with a cylinder?
No. It ships prepped for a large format interchangeable core, less core, so you supply the LFIC to match your system. That is usually what a facility wants, since you can key it into an existing Sargent system without rekeying. Sargent lists it as compatible with all their key systems including Degree, Signature, KESO and XC. Keying is a required selection when you order: keyed different, keyed alike, to a key code, or none if you are supplying your own cylinder.
6) Is this Sargent mortise lock rated for a fire door?
Yes. The 8200 Series electromechanical mortise lock is UL 10C positive pressure certified with a 3-hour fire rating, so it can go on a 3-hour rated opening. Bear in mind that it is a fail-safe function, meaning it releases on power loss, so the electrical release has to be coordinated with your fire alarm and life safety sequence for the opening.
7) What is a comparable wired 12/24V electrified mortise lock from another brand?
Two close equivalents: the BEST 45HW Series wired electromechanical mortise lock, also heavy duty and 12V/24V, and the Schlage L9092EU with 03A lever, a heavy duty 12/24VDC mortise lock with request-to-exit for 1-3/4 inch doors. Note that the Schlage EU is electrically unlocked, so its power-loss behavior is the reverse of the fail-safe 8270. Command Access also offers the ML190 Series motorized mortise lock at 24VDC with field selectable EL/EU operation if you want to decide fail-safe versus fail-secure on site.
8) If I do not need access control wiring, what mechanical mortise lock can replace the Sargent 60-8270?
A hardwired lock only makes sense where there is a power supply and a credential system. For a straight mechanical opening, the Cal-Royal NM8080 is a Grade 1 heavy duty storeroom mortise lockset for 1-3/4 inch doors with an interchangeable core option, and the Accentra 8805FL is a Grade 1 storeroom mortise lock with the Arcadia lever. The Corbin Russwin ML2003 covers classroom function at Grade 1 on 1-3/4 inch doors. All are keyed mechanical locks with no voltage requirement, unlike the 12 to 24VDC Sargent 60-8270.
9) What is the closest wired electrified mortise lock to the Sargent 60-8270 if I need another brand?
The BEST 45HW Series is the nearest equivalent: a wired electromechanical mortise lock with 12V/24V operation and heavy duty construction, matching the Sargent 60-8270's 12 to 24VDC electromechanical operation and heavy duty rating. The Schlage L9092EU with the 03A lever is another wired option, an electric lock/unlock outside lever mortise lock with keyed outside and request-to-exit, rated 12/24VDC for 1-3/4 inch doors. The Sargent is a fail-safe function, so confirm the peer is ordered fail-safe rather than fail-secure before swapping.
10) Can I use a standalone keypad mortise lock instead of running wire for the Sargent 60-8270?
Yes, if the opening does not need to be on a panel. The Alarm Lock DL3500CR is a Grade 1 electronic mortise lock with 300 user codes in classroom function for 1-5/8 to 1-7/8 inch doors, and the BEST 45HZ EZ Series is an electronic keypad mortise lock with key override. The Schlage CO-100 is a standalone electronic mortise lock with a keypad reader, Grade 1 heavy duty, privacy function, for 1-3/4 inch doors. These operate on battery power at the door, where the Sargent 60-8270 draws 12 to 24VDC from a building supply and holds its fail-safe state from that circuit.
11) What credential-reading mortise lock should I specify if the Sargent 60-8270 has no reader?
The Sargent 60-8270 is the electrified lock body only and takes its unlock signal from a separate reader and panel. If you want the credential at the lock, the Schlage LEMD-GRW is a Grade 1 ENGAGE Series wireless mortise lock with a 125kHz proximity reader and 3 hour fire rating, the TownSteel FME-2000 is a Grade 1 heavy duty classroom mortise lockset with RFID for 1-3/4 inch doors, and the Accentra NTM623-NR nexTouch Generation 3 mortise lock uses a capacitive touchscreen keypad with cylinder override.
12) My doors are 1-5/8 inch - is the Sargent 60-8270 still the right lock?
The Sargent 8200 electromechanical mortise lock is built for 1-3/4 inch door thickness. For thinner doors, the Alarm Lock Trilogy line covers 1-5/8 to 1-7/8 inch: the DL2700CR is a Grade 1 classroom electronic mortise lock with a weatherproof design, the DL3500CR is Grade 1 classroom with 300 user codes, and the DL4500DB is a Grade 1 electronic mortise deadbolt with 2,000 user codes and a privacy keypad.
13) Should I pick the LN rose or the WT escutcheon for the Sargent 8200 lock?
LN is a 2 inch round sectional rose, which is the usual choice on a wood or hollow metal door where you want a compact trim and a separate cylinder. The WT escutcheon is a 2-1/2 by 7-3/8 inch plate, which covers a larger area of the door face, so it is the one to specify if you are replacing an older escutcheon lock and need to hide existing prep or scarring. Both come in satin chrome (26D) with the A lever, in either voltage and either hand.
14) Is the Sargent 8200 durable enough for a high traffic entrance in a school or hospital?
It is a Grade 1 heavy duty commercial mortise lock UL tested to 16 million cycles, which is well beyond what Grade 1 requires and is why it turns up on main entrances, corridors and healthcare openings. For standardizing a facility, the same 8200 body takes the full range of Sargent key systems, so you can put it on the high traffic doors and keep everything on one keyway.
15) What is the difference between this wired Sargent 8200 electromechanical lock and a battery keypad mortise lock?
The 8270 is a hard-wired lock: it needs 12 to 24VDC run to the door through a power transfer hinge or loop, and it is controlled by an access control system rather than by codes at the door. If you do not have power at the opening, a standalone keypad mortise lock makes more sense, for example the Alarm Lock DL3500CR Trilogy, a Grade 1 electronic mortise lock with 300 user codes in classroom function, or the BEST 45HZ EZ Series keypad mortise lock with key override. The tradeoff is that standalone locks are managed at the door, not from a head end.
16) Is the Schlage LEBMB-ADD a substitute for the Sargent 60-8270?
Not on a Grade 1 spec. The Schlage LEBMB-ADD is a Grade 2 mobile-enabled mortise lock with push button and LED, carrying a 3 hour fire rating for 1-3/4 inch doors. The Sargent 60-8270 is Grade 1. If the drawing calls Grade 1 electrified mortise, look instead at the Schlage LEMD-GRW, which is Grade 1 with the same 3 hour fire rating.
17) The BEST 45H lock body looks similar - what is the difference from the Sargent 60-8270?
The BEST 45HCAC is a mechanical heavy duty mortise lock body in public entrance function with field reversible operation, and the 45HCAINL is a heavy duty lockbody with intruder function. Neither takes power. The Sargent 60-8270 is an electromechanical fail-safe lock running 12 to 24VDC. Within the BEST line, the 45HW Series is the wired electromechanical version with 12V/24V operation.
18) What electrified mortise option works for a card-and-keypad opening on an aluminum stile door rather than the Sargent 60-8270?
The Sargent 60-8270 uses a 2-3/4 inch backset mortise body sized for 1-3/4 inch doors. For narrow or aluminum stile work, the Dormakaba E-Plex E2066 Series electronic pushbutton keyless mortise lock is listed for wide stile, and the Alarm Lock DL1300NW Trilogy Networx wireless electronic mortise lock with keypad is built for Adams Rite deadlatches. The Dormakaba E5086 adds pushbutton and card in a back-to-back Grade 1 mortise configuration.
19) Does the Dormakaba Saffire LX-I-M002 meet the same spec as the Sargent 60-8270?
Not on grade. The Dormakaba LX-I-M002 Saffire is an electronic RFID mortise lockset with BLE mobile access rated BHMA Grade 2. The Sargent 60-8270 is Grade 1. For a Grade 1 RFID mortise lockset, the TownSteel FME-2000 and FME-4000 are both Grade 1 heavy duty classroom mortise locksets with RFID for 1-3/4 inch doors, the FME-4000 adding electronic intruder classroom function.
20) Which mortise lock should I use on the non-access-controlled doors in the same job as the Sargent 60-8270?
Openings that only need latching or privacy do not need the electrified body. The Falcon MA101 is a Grade 1 heavy duty fire-rated mortise passage lock with field reversible operation, the Schlage PM010 is a Grade 1 passage latch mortise lock for 1-3/4 inch doors, and the Hager 3840S is a Grade 1 privacy mortise lock with a 2-3/4 inch backset for 1-3/4 to 2 inch doors - the same 2-3/4 inch backset the Sargent 8200 uses.
21) For a behavioral health or ligature-resistant opening, what replaces the Sargent 60-8270?
The TownSteel MRX-L-01 is a Grade 1 heavy duty anti-ligature lever mortise lockset in stainless steel for 1-3/4 inch doors, and the MRX-A-01 is the same Grade 1 heavy duty passage function with satin stainless ligature resistant arch trim. The Marks USA 5PDN is a Grade 1 hospital passage mortise push/pull paddleset, ligature resistant and ADA compliant. The Sargent 60-8270 uses a standard A lever with LN rose or WT escutcheon trim, which is not a ligature-resistant profile.
22) Are the Emtek and Baldwin mortise locks alternatives to the Sargent 60-8270?
No. The Emtek 3019 Brisbane, 3102 Memphis, 3104 Hamilton and 3106 Manhattan mortise entrance locksets are dummy function, meaning no latch operation at all. The Baldwin 6301LS entrance/apartment and 6310190RRLS entrance/storeroom mortise locks use a 2-1/2 inch backset. The Sargent 8200 electromechanical lock uses a 2-3/4 inch backset with a 3/4 inch latchbolt throw, so the Baldwin bodies will not drop into the same mortise pocket prep.
23) Is there an installation template for prepping the door for the Sargent 8200 mortise lock?
Yes. Sargent publishes a 7800 and 8200 Series mortise lock installation template that covers all sectional rose trims and escutcheon trims, so it works for both the LN rose and the WT escutcheon versions. There is also the full 7800/8200 mortise lock catalog for lock body and trim dimensions before you cut the pocket.
24) What finish and lever does the Sargent 8270 electromechanical mortise lock come in?
Satin chromium plated over nickel (26D) with the A lever, a straight return lever. 26D is the standard commercial satin chrome finish, so it matches most existing brushed chrome hinges, closers and exit devices already on a commercial building.
25) I need an escutcheon-trim mortise lock to match the Sargent 60-8270 WT escutcheon on adjacent doors - what works?
The Sargent 60-8270 offers a WT escutcheon at 2-1/2 inch by 7-3/8 inch or an LN rose at 2 inch. For matching escutcheon-trim mortise locks on non-electrified openings, the Hager 3810E is a Grade 1 passage mortise lock with escutcheon and 2-3/4 inch backset for 1-3/4 to 2-1/2 inch doors, and the Hager 3850E is a Grade 1 non-keyed office mortise lock with lever and escutcheon on the same 2-3/4 inch backset. Both share the Sargent's 2-3/4 inch backset.
How fast can I get the Sargent 60-8270-24V-LNA-26D-RH delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Sargent 60-8270-24V-LNA-26D-RH come with a warranty?
Absolutely. The Sargent 60-8270-24V-LNA-26D-RH is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Sargent 60-8270-24V-LNA-26D-RH?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Sargent 60-8270-24V-LNA-26D-RH from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.