Square D BGA-260301 PowerPacT ...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$931.81

Square D BGA-260301 PowerPacT B 2-Pole Thermal Magnetic Circuit Breaker, 18kA

(No reviews yet) Write a Review

Model: BGA24100Y1

In Stock (leaves warehouse same day if ordered before 3pm ET)

$931.81
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Square D BGA-260301 PowerPacT B 2-Pole Thermal Magnetic Circuit Breaker, 600Y/347VAC, 18kA

The Square D PowerPacT B-Frame circuit breaker delivers thermal-mechanical circuit protection in a compact design built for I-Line panelboard installations. This 2-pole (AB frame) breaker is rated 600Y/347VAC (Ue 525V AC 50/60Hz per UL 489) with an 18kA interrupting rating (Ics) and a thermal magnetic trip for overcurrent protection, and is available with Motor FLA ratings from 30A to 100A to match the load requirements of the installation. It is UL 489 listed and HACR rated, making it a dependable choice for commercial and industrial distribution panels.

Key Features

  • Motor FLA Range: Available in ratings from 30A to 100A to suit a variety of motor and branch-circuit protection needs.
  • Pole Configuration: 2-pole (AB frame) design for I-Line panelboards.
  • Connection Type: I-Line connection on the line side, lug connection on the load side.
  • Electrical Rating: 600Y/347VAC operational voltage with an 18kA interrupting rating (Ics) at 500-525V AC per IEC 60947-2.
  • Trip Type: Thermal magnetic circuit protection for overload and short-circuit response.
  • Insulation & Withstand: Rated insulation voltage (Ui) of 800V and rated impulse withstand voltage (Uimp) of 8kV per IEC 60947-2.
  • Durability: 20,000 mechanical operating cycles and 10,000 electrical cycles per IEC 947-1 Annex K.
  • Wire Range: AWG 14-AWG 2/0 aluminum/copper, tightening torque 3.6-4.4 N.m (AWG 14-10) and 5-6.2 N.m (AWG 8-2/0).
  • Finish: Gray (RAL 7016) housing, IP40 degree of protection on the front cover.

Certifications & Compliance

  • UL 489 Listed
  • CSA C22.2 No. 5
  • NEMA AB1
  • EN/IEC 60947-2
  • EN/IEC 60947-5-1
  • GB 14048.2
  • NMX J-266
  • HACR Rated

Technical Specifications

  • Poles Description: 2P
  • Motor FLA Options: 30A, 100A
  • Voltage Rating: 600Y/347VAC
  • Interrupting Rating (Ics): 18kA
  • Insulation Voltage (Ui): 800V
  • Impulse Withstand (Uimp): 8kV
  • Wire Range: AWG 14 - AWG 2/0 aluminum/copper
  • Mechanical Life: 20,000 operating cycles
  • Electrical Life: 10,000 cycles

Typical Applications

  • Commercial and Industrial Electrical Distribution
  • I-Line Panelboard Installations
  • Load Center and Distribution Panel Protection
  • OEM and Control Panel Building
  • New Construction and Retrofit Upgrades

Why Square D?

Square D engineers the PowerPacT B-Frame breaker for reliable, code-compliant thermal magnetic protection backed by UL 489 listing and IEC 60947-2 certification. Its rugged construction supports 20,000 mechanical cycles, making it a dependable choice across the 30A to 100A Motor FLA range for I-Line panelboard installations in commercial and industrial distribution systems.

Manufacturer Resources

Product Specs

Product Type:
Circuit Breaker
Configuration:
2-Pole
Voltage Rating:
600Y/347VAC
Connection Type:
I-Line
Listing:
UL Listed
Standards:
UL 489
Product Color:
Gray
Department:
Electrical
Product Group:
Circuit Protection
Amperage Rating:
30A - 100A
Product Finish:
Gray (RAL 7016)
Product Subgroup:
Circuit Breakers

Square D BGA24100Y1 – Frequently Asked Questions

1) Will the Square D PowerPacT B-Frame BGA breaker mount in an I-Line panelboard?
Yes. The PowerPacT B-Frame 2-pole BGA breaker uses an I-Line connection on the line side, so it plugs onto I-Line bus stabs, with lug connections on the load side. That makes it a drop-in for I-Line panelboard distribution rather than a bolt-on or plug-on load center breaker.
2) What amp ratings does the Square D BGA 2-pole PowerPacT B breaker come in?
Two Motor FLA ratings are offered on the 2-pole BGA breaker: 30A (BGA260301) and 100A (BGA24100Y1). The published range is 30A to 100A, so if your branch circuit or motor load falls between those two values you need to pick the rating that matches the load, not an intermediate trip setting - this is a fixed thermal magnetic breaker, not an adjustable electronic trip unit.
3) Can I use this breaker on a 480V or 600V three-phase system?
The BGA 2-pole PowerPacT B breaker is rated 600Y/347VAC, which covers 480Y/277V and 600Y/347V wye-connected systems. Its UL 489 rated operational voltage is listed as Ue 525V AC 50/60Hz. Note the Y rating: it is intended for solidly grounded wye systems, so a 600V delta or corner-grounded delta service is outside what is published for it.
4) Is 18kA enough interrupting capacity for my panel?
The BGA 2-pole breaker carries an 18kA interrupting rating (Ics), stated at 500-525V AC per IEC 60947-2. Compare that against the available fault current at the panelboard from your utility or coordination study. If your calculated fault current at that point exceeds 18kA and you have no upstream series rating or current-limiting fuse to back it up, you need a higher AIC frame instead.
5) Can I use an ABB ST200M miniature circuit breaker instead of the Square D PowerPacT B breaker?
No. The ABB ST200M is a C-curve miniature circuit breaker listed to UL 1077, which is a supplementary protector standard. The Square D PowerPacT B BGA is UL 489 listed, which is the standard for branch-circuit protection. If the drawing calls for branch-circuit or feeder protection, the UL 489 device is required; a UL 1077 supplementary protector cannot take its place.
6) I need a 3-pole breaker instead of the Square D PowerPacT B 2-pole - what are the options?
The Square D PowerPacT B BGA breaker is a 2-pole configuration only. For three-pole molded case protection, the ABB XT4 Series 3-pole molded case circuit breaker kit and the ABB XT5 3-pole circuit breaker kit are both 3-pole molded case devices, and the ABB A2A150TT is a 3-pole molded case breaker in the A2 Series. Confirm the panelboard mounting system before ordering, since the PowerPacT B uses an I-Line connection.
7) What is the difference between the Square D PowerPacT B breaker and an Eaton BAB Quicklag breaker?
The Square D PowerPacT B BGA is a 2-pole thermal magnetic breaker rated 600Y/347VAC with an I-Line connection for panelboard bus mounting. The Eaton BAB Quicklag industrial thermal-magnetic breaker is a 240V, three-pole bolt-on style device. Both are thermal-magnetic, but the voltage class and the mounting method are different, so the BAB suits 240V bolt-on panel applications while the PowerPacT B covers 600Y/347VAC I-Line distribution.
8) What wire size and torque does the load side lug on this PowerPacT B breaker take?
The load lugs accept AWG 14 through AWG 2/0, aluminum or copper. Tighten to 3.6-4.4 N.m for AWG 14-10 and 5-6.2 N.m for AWG 8-2/0. At the 100A rating you will be at the upper end of that range, so plan conductor size accordingly before you pull wire.
9) Is this breaker approved for HVAC equipment and rooftop units?
Yes. The PowerPacT B-Frame BGA breaker is HACR rated and UL 489 listed, which is what inspectors look for when a breaker feeds heating, air conditioning and refrigeration equipment. It also carries CSA C22.2 No. 5, NEMA AB1 and EN/IEC 60947-2 compliance for projects that call for Canadian or international listings.
10) Thermal magnetic or electronic trip - which do I need for a motor feeder?
This BGA breaker is thermal magnetic, meaning fixed overload and short-circuit response with no adjustable pickup or time delay. For a standard motor branch circuit or feeder inside the 30A to 100A range that is normally all that is required, and it is the simpler and smaller option. Where you need adjustable long-time, short-time or ground-fault settings for selective coordination with downstream devices, an electronic trip unit frame is the better choice.
11) What else could I use instead of a Square D PowerPacT B 2-pole molded case breaker?
If the opening is not an I-Line panelboard, the alternatives are different in how they connect. ABB's A2A150TT is a 3-pole molded case breaker in the A2 Series, and ABB offers 3-pole kits in the XT4 and XT5 series. For bolt-on branch breaker applications rather than molded case, Eaton's BAB Quicklag thermal-magnetic line includes bolt-on 2-pole and 3-pole devices. None of those will land on an I-Line bus, so the choice follows the panel you are feeding, not just the amp rating.
12) I need a 3-pole breaker for a three-phase load. Does the BGA cover that?
The BGA breaker described here is a 2-pole AB frame device. For a three-phase load you need a 3-pole breaker. Among other brands we carry, the ABB A2A150TT is a 3-pole molded case breaker and the ABB XT4 and XT5 kits are 3-pole, and Eaton's BAB-302 Quicklag is a three-pole 240V thermal-magnetic unit. Match the connection method to your panel before you order.
13) The Square D PowerPacT B tops out at 100A motor FLA - what should I look at for a larger frame?
The PowerPacT B BGA breaker covers a 30A to 100A amperage range in a 2-pole build. For a substantially larger frame, the Eaton Series C K-Frame mining circuit breaker is a 400A 3-pole device with an interchangeable rating plug. Note the pole count and mounting differ from the I-Line 2-pole PowerPacT B, so verify the panel and the application before specifying it.
14) How many operations will this breaker take if it gets switched regularly?
Rated life on the BGA 2-pole breaker is 20,000 mechanical operating cycles and 10,000 electrical cycles per IEC 947-1 Annex K. That is adequate for routine maintenance switching in a distribution panel. For an application where the breaker is being used as a frequent on/off disconnect for process equipment, a contactor or motor starter ahead of it is the better way to absorb the cycling.
15) What is the enclosure protection rating and color on the Square D PowerPacT B BGA breaker?
Housing is gray, RAL 7016, with IP40 degree of protection on the front cover. IP40 means it is protected against solid objects over 1mm but has no water ingress rating, so it needs to live inside a panelboard or a suitably rated enclosure rather than in the open.
16) What insulation and impulse withstand voltage does this breaker hold for control panel builds?
Rated insulation voltage (Ui) is 800V and rated impulse withstand voltage (Uimp) is 8kV per IEC 60947-2. Those are the numbers an OEM panel builder needs for clearance and creepage calculations and for IEC-referenced panel documentation.
17) Does the Square D PowerPacT B BGA breaker include an undervoltage release like the Eaton NZM accessory?
No. The PowerPacT B BGA is a thermal magnetic breaker with a thermal magnetic trip for overload and short-circuit response, supplied as the breaker itself. The Eaton 10250T Series item is an undervoltage release accessory for NZM Series molded case breakers, not a breaker, and it is built for the NZM frame rather than the PowerPacT B.
How fast can I get the Square D BGA24100Y1 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Square D BGA24100Y1 come with a warranty?
Absolutely. The Square D BGA24100Y1 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Square D BGA24100Y1?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Square D BGA24100Y1 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.