Square D TeSys K Series 3-Pole Contactor, 24VDC Coil

The Square D TeSys K Series contactor from Schneider Electric is a compact 3-pole contactor line built for motor control and resistive-load switching in commercial and industrial control panels. This family is available in AC-3 ratings from 9A to 20A, each version equipped with a 24V DC control coil and 1 NO auxiliary contact for straightforward integration into control systems. Every model in the series carries UL 60947-4-1/60947-5-1 and CSA C22.2 No 60947-4-1/60947-5-1 listings, giving panel builders and OEMs a dependable, code-compliant switching solution across a range of motor full-load-amp requirements.

Key Features

  • 3-Pole Design: Compact TeSys K contactor configuration for motor control and resistive-load applications.
  • Rated Operational Current Range: AC-3 ratings spanning 9A to 20A (at <60°C) at <= 440V AC across the series, sized to the motor load.
  • Motor Power: Power ratings scale with the selected amperage, supporting 380...415V AC 50/60Hz AC-3 and 220...230V AC 50/60Hz AC-3 duty.
  • Control Coil: 24V DC standard control circuit shared across the family for reliable low-voltage actuation.
  • Auxiliary Contact: 1 NO auxiliary contact on each model for easy integration into control and signalling circuits.
  • Utilisation Categories: AC-1, AC-3, AC-3e, and AC-4 duty ratings for varied load types across the series.
  • Electrical Durability: Extended service life at rated AC-3e/AC-3 current up to 440V.
  • Connections: Screw clamp terminals rated 1.5-4 mm² solid / 0.75-4 mm² flexible conductors.

Certifications & Compliance

  • UL 60947-4-1 / UL 60947-5-1
  • CSA C22.2 No 60947-4-1 / No 60947-5-1
  • EN/IEC 60947-4-1 / EN/IEC 60947-5-1
  • GB/T 14048.4
  • UKCA, CB Scheme, CCC, EAC, CE
  • RoHS Compliant, Reach Compliant

Technical Specifications

  • Product Type: Contactor
  • Configuration: 3-Pole
  • Voltage Rating: 600V
  • Amperage Rating: 9A-20A (family range)
  • Listing: UL Listed
  • Toxic Heavy Metal Free: Yes
  • Warranty Period: 18 months
  • Sustainable Packaging: Yes
  • With Recycled Cardboard: Yes
  • Mercury Free: Yes
  • ROHS Eur In Scope: Yes

Typical Applications

  • Motor Control Circuits
  • Resistive Load Switching
  • Commercial and Industrial Control Panels
  • OEM Machine Building
  • Panel Builder and System Integrator Installations

Why Square D?

Square D's TeSys K contactor series delivers dependable motor and load switching backed by UL, CSA, and EN/IEC 60947 series listings, with an 18-month warranty and sustainable, recycled-content packaging across the range. Its screw-clamp terminals and shared 24V DC coil design provide code-compliant, reliable performance for professional electrical control panel work, whatever amperage in the 9A-20A range your application requires.

Manufacturer Resources

Product Specs

Product Type:
Contactor
Voltage Rating:
600V
Amperage Rating:
9A-20A
Series:
TeSys K
Connection Type:
Screw Clamp
Listing:
UL Listed
Standards:
UL 60947-4-1
Department:
Electrical
Product Group:
Motor Control & Automation
Configuration:
3-Pole
Product Subgroup:
Contactors & Relays

Square D LP1K0910BD – Frequently Asked Questions

1) Will a Square D LP1K contactor work with a 24V DC control circuit from my PLC?
Yes. Every LP1K TeSys K contactor in this family uses a 24V DC control coil, so it drops straight onto a 24V DC control circuit driven by a PLC output or control transformer with a DC supply. There is no AC coil option within this group, so if your panel runs a 120V AC control circuit you need a different coil voltage.
2) Which LP1K do I order for my motor, the 9A or the 20A?
Pick by the motor's full-load amps. The TeSys K line is offered here in two AC-3 sizes, 9A (LP1K0910BD) and 20A (LP1K09008BD), and the series range is 9A to 20A at under 60 degrees C up to 440V AC. Size the contactor so the motor FLA from the nameplate falls at or below the AC-3 rating, not above it.
3) I just need to rebuild an existing contactor, not replace the whole device. Is the LP1K the right thing to buy?
No. The LP1K is a complete 3-pole contactor, not a repair part. If you are refreshing a contactor already in the panel, look at renewal kits instead: Eaton offers a Freedom Series A1 contactor kit, a Citation B1 three-pole contactor renewal kit, and a Freedom coil and contactor kit for 220-240V AC in the 65mm frame. Those replace contacts and coils in their matching Eaton frames and will not fit a Square D TeSys K.
4) Does the Square D LP1K include overload protection for the motor?
No. The LP1K is the switching contactor only, with 3 power poles and one NO auxiliary contact. Motor overload protection has to come from a separate thermal overload relay or an electronic protection device, plus short-circuit protection upstream. If you want switching and overload in one package, an integrated starter such as the Eaton AE16 Series contactor/starter is the other approach.
5) What is the closest IEC equivalent to the Square D LP1K 3-pole contactor from another manufacturer?
The ABB AF16 contactor, part number AF-09301013, is the nearest match in form and function: it is a 3-pole IEC contactor with a 1 NO auxiliary contact and a 9-16A AC-3 rating, which overlaps the 9A-20A AC-3 range the Square D LP1K TeSys K family covers. Both are panel-mount IEC frames intended for motor control. Confirm the coil on the ABB unit matches your control circuit, since the LP1K versions are built around a 24V DC coil.
6) Can I use an Eaton AE16 contactor in place of a Square D LP1K TeSys K contactor?
The Eaton AE16 is a three-phase IEC contactor/starter for motor control, part number AE-16LN0A, so it addresses the same job as the Square D LP1K TeSys K 3-pole contactor in a motor control panel. The differences to verify before swapping are coil voltage - the LP1K family is specified with a 24V DC control coil - and the terminal arrangement, since the LP1K uses screw clamp terminals rated for 1.5-4 mm2 solid and 0.75-4 mm2 flexible conductors. Mounting footprint and DIN rail layout should also be checked against your existing panel.
7) My existing Eaton Freedom contactor failed - do I need a whole new contactor like the Square D LP1K, or is there a repair option?
If the existing device is an Eaton Freedom starter, Eaton publishes renewal parts rather than requiring a full replacement: the Freedom A1 contactor kit, part 6-44-2, and the Freedom coil and contactor kit 932563 for 220-240V AC 65mm frames are renewal parts that rebuild the unit in place. The Square D LP1K TeSys K 3-pole contactor is a complete new contactor with a 24V DC coil and 1 NO auxiliary contact, so it is the path when you are replacing the device outright or building a new panel, not when you are rebuilding an existing Eaton frame.
8) I need a contactor for a 240V AC control circuit - is the Square D LP1K the right choice?
Not as specified. The Square D LP1K TeSys K versions are built with a 24V DC control coil shared across the family, so they suit low-voltage DC control from a PLC or 24V supply. For a 220-240V AC control circuit on an Eaton Freedom frame, Eaton part 932563 is a coil and contactor kit rated 220-240V AC for a 65mm frame. Match the coil voltage to the control transformer or supply feeding the circuit before ordering either.
9) Do I need to add an auxiliary contact block to an LP1K for a run-status signal?
Not for a single signal. Each LP1K in this group ships with 1 NO auxiliary contact built in, which is enough for a seal-in circuit or a run indication back to the controller. If you need additional NO or NC contacts beyond that one, you will need a separate add-on auxiliary block.
10) Can the LP1K switch a resistive heater load rather than a motor?
Yes. The TeSys K series is rated for AC-1 duty as well as AC-3, AC-3e and AC-4, so resistive-load switching such as heater banks is within its intended use. Note that resistive loads are sized on AC-1, not the AC-3 motor rating, so do not read the 9A or 20A AC-3 figure as the heater rating.
11) What voltage can I switch through a TeSys K LP1K contactor?
The contactor carries a 600V rating on the power poles, and the AC-3 motor duty is specified up to 440V AC, with motor power figures given for 380 to 415V AC and 220 to 230V AC at 50/60Hz. For three-phase 480V motor circuits confirm the AC-3 rating at your voltage before committing.
12) What is a comparable 3-pole IEC contactor to the Square D LP1K if I need a different brand?
Two close alternatives sold alongside it: the ABB AF16, part AF-09301013, is a 3-pole contactor with a 1NO auxiliary contact rated 9-16A AC-3, which sits inside the same amperage band as the LP1K. The Eaton AE16 Series is a three-phase IEC contactor/starter for motor control in the same frame class. Both are IEC-style devices like the TeSys K, so panel layout and wiring practice carry over, though coil voltage and mounting dimensions differ by brand.
13) Is the Eaton Citation B1 renewal kit a substitute for a Square D LP1K contactor?
No. Eaton part 6364 is a Citation B1 three-pole contactor renewal kit, meaning it supplies replacement contactor components for an existing Citation B1 assembly rather than a standalone device. The Square D LP1K TeSys K is a complete 3-pole contactor rated 600V with a 9A-20A AC-3 range and UL 60947-4-1 listing. The two are not interchangeable: use the Eaton kit only to rebuild a Citation B1, and the LP1K where a full contactor is being installed.
14) For a UL-listed motor control panel, how does the Square D LP1K compare with the ABB AF16 on ratings I can submit?
The Square D LP1K TeSys K carries UL 60947-4-1 and UL 60947-5-1 plus CSA C22.2 No 60947-4-1 and No 60947-5-1 listings, is rated 600V, and covers AC-1, AC-3, AC-3e and AC-4 utilisation categories across the 9A-20A AC-3 range. The ABB AF16 comparable, AF-09301013, is published with a 9-16A AC-3 rating and a 1 NO auxiliary contact. If your submittal has to show AC-4 duty or the CSA listing explicitly, the LP1K documentation states both.
15) Are Square D TeSys K contactors RoHS compliant and free of heavy metals for a green building spec?
Yes on both counts. The TeSys K line is RoHS and REACH compliant, mercury free and toxic heavy metal free, and ships in sustainable packaging using recycled cardboard. That is usually enough documentation for a sustainability-driven procurement spec.
How fast can I get the Square D LP1K0910BD delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Square D LP1K0910BD come with a warranty?
Absolutely. The Square D LP1K0910BD is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Square D LP1K0910BD?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Square D LP1K0910BD from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.