1 1/2 In Lead Free Reduced Pressure Zone Backflow Preventer Assembly, Quarter Turn Shutoff Valves, Lever Handles
LF009M2-QT 1 1/2 - spec sheet
LF009M2-QT 1 1/2 - spec sheet
Manufacturer Resources
Product Specs
- Backflow Preventer Type:
- Reduced Pressure Zone Assembly
- Body Finish:
- Cast Bronze
- Body Material:
- Lead Free Bronze
- Body Pattern:
- Inline
- Buy American Act Compliant:
- USA
- Bypass:
- No
- Cap And Tether:
- No
- Disc Material:
- Silicone
- Ean:
- 98268051155
- Elbow Fitting:
- No
- Hazard Protection Level:
- Health Hazard
- Hot And Harsh Water:
- No
- Hydrant Connection:
- No
- Inlet Connection Size:
- 1 1/2 IN
- Inlet Connection Size Metric:
- 40 MM
- Inlet Connection Type:
- Female Threaded
- Inlet Shutoff Valve Type:
- Quarter Turn Ball Valve
- Inlet Thread Type:
- NPT
- Lead Free:
- Yes
- Maximum Temperature Fahrenheit:
- 180
- Maximum Working Pressure Bar:
- 12
- Maximum Working Pressure Psi:
- 175
- Meter Type:
- No Meter
- Minimum Temperature Celsius:
- 0.5
- Minimum Temperature Fahrenheit:
- 33
- Outlet Connection Size:
- 1 1/2 IN
- Outlet Connection Type:
- Female Threaded
- Outlet Shutoff Valve Type:
- Quarter Turn Ball Valve
- Outlet Thread Type:
- NPT
- Part Number:
- 391006
- Polymer Coating:
- No
- Pressure Operation:
- Continuous
- Protection Type:
- Backpressure and Backsiphonage
- Seat Material:
- Engineered Plastic
- Series:
- LF009
- Strainer:
- No
- Tradename:
- None
- Department:
- Plumbing
- Product Group:
- Plumbing
- Product Subgroup:
- Valves
- Product Type:
- Backflow Preventer
- Brand Name:
- Watts
- Product Details:
- Kit
Watts LF009M2-QT 1 1/2 – Frequently Asked Questions
1) What pipe connection does the Watts LF009M2-QT 1-1/2 backflow preventer need?
Both ends are 1-1/2 inch female NPT threaded (40 mm), inlet and outlet alike. So you thread into male NPT nipples on each side. There's no elbow fitting and no strainer included, so if the supply needs a strainer or a change of direction, plan those as separate fittings.
2) Can an RPZ like the Watts LF009M2-QT be used on a high hazard connection?
Yes. The LF009M2-QT is a reduced pressure zone assembly rated for health hazard protection, and it guards against both backpressure and backsiphonage. That is the combination you need where a cross connection could carry something harmful back into potable water, which is where a double check assembly is not enough.
3) Is the Watts LF009M2-QT lead free for potable water?
Yes, the body is lead free cast bronze and the assembly is flagged lead free, which is what a potable water installation in a commercial or multifamily building needs. Internals use a silicone disc and engineered plastic seat.
4) Does the LF009M2-QT come with shutoff valves, or do I buy those separately?
Shutoffs are included on both ends. The QT suffix means quarter turn ball valves with lever handles on the inlet and the outlet, so the assembly arrives as a complete kit ready to isolate for testing.
5) Is the Watts LF009M2-QT rated for continuous pressure service?
It is. Pressure operation is continuous, with a maximum working pressure of 175 psi (12 bar), so it can sit under constant line pressure on a domestic or irrigation feed rather than intermittent duty only.
6) What water temperature range can this 1-1/2 inch RPZ handle?
33 F to 180 F is the operating range on the LF009M2-QT. It is not built for hot or harsh water service, so keep it off recirculating hot water and boiler feed lines running above that. Freeze protection still matters at the low end, since 33 F leaves no margin in an unheated space.
7) Does this Watts RPZ include a bypass line or a water meter?
No. The LF009M2-QT is a plain inline assembly with no bypass, no meter, and no cap and tether. If your jurisdiction or fire service requires a metered bypass around the assembly, that has to be a separate configuration.
8) Is the Watts LF009M2-QT made in the USA for a Buy American job?
Yes, it is listed as Buy American Act compliant, country USA, which is what federal, school, and municipal procurement typically needs on the submittal. Order it by Watts model LF009M2-QT 1 1/2, part number 391006.
9) Should I use an RPZ assembly or a double check valve on my 1-1/2 inch service?
Go by the hazard. A reduced pressure zone assembly like the LF009 is the one approved for health hazard (high hazard) cross connections, covering backpressure and backsiphonage, and it has a relief port that discharges when the check seals fail, so it needs an air gap drain and cannot go in a pit that could flood. A double check assembly is for non health hazard service only and has no relief discharge, which is why it is often chosen where drainage is impossible.
How fast can I get the Watts LF009M2-QT 1 1/2 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the
continental
U.S.
Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit,
reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Watts LF009M2-QT 1 1/2 come with a warranty?
Absolutely. The Watts LF009M2-QT 1 1/2 is backed by a manufacturer’s warranty.
For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Watts LF009M2-QT 1 1/2?
You can call, text, or email our expert support team for fast answers. We’re here to help with
product
selection,
installation tips, and troubleshooting. Contact Us
Why buy the Watts LF009M2-QT 1 1/2 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support,
and
rewards on
every order.
Our team is always ready to help you choose the right product for your project.