Carlon 1/2 Inch Blue Non-Metallic ENT Flexible Raceway
Professional-Grade Electrical Conduit Solution
The Carlon 1/2 Inch Blue ENT Flexible Raceway delivers professional-grade electrical conduit performance for residential and commercial wiring applications. This non-metallic flexible tubing features industry-standard blue color coding designed for electrical contractors and installers, providing the reliable performance and UL Listed safety that electrical professionals demand for wall, floor, and non-plenum ceiling installations.
Professional Features & Benefits
Superior Construction Quality
- 0.56 inch inside diameter with 0.84 inch outside diameter - Optimal wire capacity and pull-through performance for 1/2 inch applications
- Non-metallic flexible construction - Lightweight design reduces installation time while providing excellent bend radius capabilities
- Industry-standard blue color coding - Easy identification and code compliance for electrical raceway systems
- Flexible raceway design - Accommodates complex routing through walls, floors, and ceiling spaces
UL Listed Safety & Compliance
- UL E73317 Listed certification - Meets stringent electrical safety standards for professional installations
- Code compliant installation - Approved for use in walls, floors, and non-plenum ceilings per electrical codes
- PVC fitting compatibility - Recognized for use with PVC rigid non-metallic conduit fittings for all ENT sizes
Technical Specifications
This 1/2 inch ENT flexible raceway features 0.56 inch inside diameter and 0.84 inch outside diameter construction in durable non-metallic material. UL E73317 Listed for electrical safety compliance with blue color coding for easy identification. Sold per foot for flexible project planning and precise material ordering.
Installation Process
- Plan raceway route ensuring compliance with electrical codes for wall, floor, or non-plenum ceiling applications
- Measure and cut ENT tubing to required length using appropriate cutting tools for clean, square cuts
- Install compatible PVC rigid non-metallic conduit fittings at connection points for secure raceway system
- Route flexible tubing through framing, maintaining proper support intervals per electrical code requirements
- Secure raceway system using appropriate fasteners and support methods for permanent installation
- Verify all connections are tight and raceway system provides smooth wire pulling path before wire installation
Professional Applications
Ideal for:
- Residential Wiring Systems - New construction and remodel projects requiring flexible conduit routing through walls and floors
- Commercial Electrical Installations - Office buildings, retail spaces, and light commercial applications with complex wiring paths
- Wall Cavity Wiring - Flexible routing through wall studs and around obstacles in residential and commercial construction
- Floor System Applications - Under-floor wiring systems where flexible conduit provides optimal routing capabilities
- Non-Plenum Ceiling Installations - Ceiling cavity wiring where plenum-rated materials are not required
- Retrofit Electrical Projects - Existing building upgrades where flexible conduit simplifies wire routing challenges
- Multi-Family Housing - Apartment and condominium electrical systems requiring efficient conduit installation methods
- Light Commercial Construction - Small office, retail, and service building electrical installations
Non-Metallic ENT Advantage
Carlon's non-metallic ENT construction provides superior corrosion resistance, lightweight handling, and excellent flexibility for complex routing applications. The blue color coding ensures easy identification and code compliance while the flexible design accommodates tight bends and obstacle navigation that rigid conduit cannot achieve, making it the preferred choice for electrical contractors working in challenging installation environments.
Why Choose Carlon Quality?
Carlon's commitment to UL Listed safety standards and reliable performance makes this ENT flexible raceway the trusted choice for electrical professionals. With decades of experience in non-metallic electrical solutions, Carlon delivers consistent quality and code compliance that electrical contractors depend on for successful project completion and long-term system reliability.
Manufacturer Resources
Product Specs
- Application:
- Flex-Plus Blue ENT is a non-metallic flexible raceway for use in walls, floors, and non-plenum ceilings.
- Color:
- Blue
- Inside Diameter:
- 0.56 in
- Material:
- Non-Metallic
- Nominal Size:
- 1/2 in
- Outside Diameter:
- 0.84 in
- Product Name:
- FLEXIBLE TUBING OF PLASTIC W/O FTG
- Product Net Depth Length:
- 1 fFT
- Product Type:
- ENT Flexible Raceway
- Selling Unit Of Measure:
- foot
- Special Functions:
- Recognized for use with PVC rigid non-metallic conduit fittings with all size of ENT.
- Standards:
- UL E73317
- Product Group:
- Conduit Systems
- Department:
- Electrical
- Product Sub group:
- Conduit & Components
- Product Type2:
- Electrical conduit