20 Amp Feed- Through, 125 Volt Receptacle, SmartlockPro Slim Blank GFCI, monochromatic, back and side wired, wallplate sold separately, self grounding clip included - RACK PACK - White
Features
- Automatically test the GFCI every time the RESET button is pushed in. The GFCI will not reset if the GFCI circuit is not functioning properly.
- A line-load reversal diagnostic feature is provided which prevents the GFCI from being reset and stops power from being fed to the GFCI receptacle face or through to downstream devices. A green LED indicator on the GFCI's face also illuminates to alert the installer to the line-load wiring reversal.
- External back wire clamps provide visual indication of proper wire seating.
- Standard brass self-grounding clip.
- Compatible with all Decora devices and wallplates; available in select Decora colors.
- Improved immunity to high-frequency noise reduces nuisance tripping.
- By blocking reset of the GFCI if protection has been compromised, SmartlockPro® Slim GFCI reduces the possibility of end-users incorrectly assuming that a reset GFCI outlet is providing ground fault protection when it actually is not.
- Trip threshold meets or exceeds UL requirements for tripping time.
- UL Fed Spec WC-596 rated.
- Withstands high torque and resists wire pullout.
- Terminals allow for easy wiring options – back and side wire capable.
- Reduced depth of SmartlockPro® Slim GFCI makes it easier to install in any electrical box, even shallow ones.
- Advanced electronics design provides superior resistance to electrical surges and over-voltages.
Manufacturer Resources
Product Specs
- At Rated Voltage:
- 1 HP
- Body Material:
- Polycarbonate
- Csa C22 2 No 144 1 06:
- File LR-57811
- Csa C22 2 No 42:
- Yes
- Face Material:
- Thermoplastic
- Fed Spec Wc 596:
- Yes
- Feed Through Current:
- 20 Amp
- Grounding Screw:
- Plated Steel
- Line Contacts:
- Brass Double-Wipe .031 Thick
- Operating Temperature:
- -35C to +66C
- Product Id:
- Ratings are permanently marked on device
- Short Circuit Current Rating:
- 10KA
- Standards And Certifications:
- UL/CSA
- Strap Material:
- Galvanized Steel
- Terminal Accom:
- 14-10 AWG
- Terminal Id:
- Brass-Hot, Green-Ground, Silver-Neutral
- Terminal Screws:
- Plated Steel
- Trip Level:
- Class A, 5mA plus or minus 1mA
- Ul 943:
- File E48380
- Product Group:
- Outlets
- Department:
- Electrical
- Product Subgroup:
- Switches & Receptacles
- Ansi:
- C-73
- Clamps:
- Brass
- Feature:
- SmartlockPro® Slim
- Flammability Class:
- Rated V-2 per UL 94
- Grounding:
- Self Grounding
- Nema:
- WD-6
- Nom:
- 57
- Ordering Notes:
- Wallplate Sold Separately
- Pole:
- 2
- Termination:
- Back & Side
- Wire Count:
- 3
- Yoke:
- Zinc-Plated Steel
- Series:
- SmartlockPro
- Product Voltage:
- 125 VAC
- Product Details:
- Blank Face
- Product Color:
- White
- Product Type:
- Receptacle
Leviton GFRBF-KW – Frequently Asked Questions
1) What is a blank face GFCI like the Leviton GFRBF-KW actually for?
The GFRBF-KW is a dead front GFCI, meaning it has a blank face with no receptacle slots. You wire it into the line side of a circuit and it feeds ground fault protection downstream to standard receptacles wired to its load terminals. Feed through current is 20 amps at 125 VAC. Use it where you need Class A ground fault protection on a circuit but do not want, or cannot have, a plug in point at that location: behind an appliance, ahead of a run of standard outlets, in a wall box where an outlet would be blocked anyway. If you want protection and a place to plug in at the same box, a standard faced GFCI duplex is the part, not this one.
2) Will a Leviton SmartlockPro Slim blank GFCI fit in a shallow old work box?
That is what the Slim body is built around. The SmartlockPro Slim GFCI has reduced depth compared to a standard GFCI so it seats in shallow boxes, and the back wire clamps are external, which keeps the wire bundle from stacking up behind the device. The body is polycarbonate with a galvanized steel strap and zinc plated steel yoke. It still takes three wires (line hot, neutral, ground) plus the load pair if you are feeding downstream, so the box has to have room for that count regardless of how thin the device is.
3) Do I need a separate grounding pigtail for the Leviton GFRBF-KW, or does it self ground?
A brass self grounding clip is included on the GFRBF-KW, so the yoke bonds to a grounded metal box through the mounting screw. In a plastic box, or any box you cannot confirm is bonded, run the ground conductor to the green grounding screw. That screw is plated steel and takes the same 14 to 10 AWG the line terminals do. A GFCI that is not properly grounded will still trip on a fault through a person, but the ground is what the tester on your belt is looking for.
4) What happens if line and load get reversed on a Leviton SmartlockPro Slim GFCI?
The GFRBF-KW will not reset, and it will not pass power to downstream devices. A line load reversal diagnostic blocks the reset and a green LED on the face lights up to tell the installer the wiring is backwards. That is a real time saver on a punch list: instead of a device that appears to work but protects nothing, you get a device that refuses to come on until the feed is on the correct terminals. Same logic applies to the self test: the GFCI tests itself each time RESET is pushed in and will not reset if the protection circuit has failed.
5) How many standard outlets can I protect downstream of one blank face GFCI?
The GFRBF-KW carries 20 amps of feed through current, so the limit is the circuit, not the device: anything you can legally put on that 20 amp branch can sit downstream on the load terminals. Short circuit current rating is 10kA. The practical constraint on a multi family or hotel job is troubleshooting, not capacity. Every downstream outlet goes dead when this one trips, and the blank face is easy for a tenant to overlook, so put it somewhere a maintenance tech will find it and label the downstream devices as GFCI protected.
6) What should I buy instead if I need a GFCI outlet with actual receptacle slots?
The GFRBF-KW has a blank face, so nothing plugs into it. If you need protection and a plug in point in the same box, the Pass & Seymour 2097HGI is a 20A self test GFCI duplex, hospital grade, in ivory. For a patient care area or anywhere a hospital grade device is specified, that one is the part. Match the amperage to your circuit: both are 20 amp devices, so either drops onto a 20 amp branch.
7) What is a good substitute for the Leviton GFRBF-KW if the outlet needs to accept a plug?
The GFRBF-KW is a blank face device, so nothing plugs into it - it protects downstream outlets through its 20 amp feed-through current. If the opening needs a receptacle face with GFCI protection built in, the Pass & Seymour 2097HGI is a 20A duplex self-test GFCI receptacle in ivory. That gives you a plug-in face at the same 20 amp class, where the blank face Leviton only feeds the circuit.
8) If the circuit does not need ground fault protection, what 20 amp white decorator receptacle can replace the Leviton GFRBF-KW?
The Pass & Seymour 26352W is a 20A 125V heavy-duty spec grade decorator duplex receptacle in white. It matches the GFRBF-KW on 125 VAC product voltage and white product color, and on the decorator opening, but it is a straight duplex with no GFCI function - the Leviton is a SmartlockPro Slim GFCI with a Class A 5mA plus or minus 1mA trip level. Where code requires GFCI protection at the circuit, the 26352W does not provide it.
9) What wire size does the Leviton GFRBF-KW GFCI accept, and can I back wire it?
Terminals take 14 to 10 AWG copper, and the device is back and side wire capable, so you can land the conductor in the external clamp or wrap the side screw. The clamps are brass, terminal and ground screws are plated steel. Terminal identification follows the standard color code on the device: brass for hot, silver for neutral, green for ground. With 10 AWG on a 20 amp circuit the back clamp is usually the easier landing than trying to form a screw wrap in a crowded box.
10) Does a blank face GFCI need a special cover plate?
No special plate, but the wallplate is sold separately with the GFRBF-KW. It takes a standard Decora style opening, the same one a rocker switch or decorator receptacle uses, and it is compatible with all Decora devices and wallplates. Since the face is blank you are covering an opening with nothing but the TEST and RESET buttons showing, so a single gang Decora plate in white matches the device color. If the device shares a box with switches, a multi gang Decora plate gangs it with them.
11) Can I install the Leviton SmartlockPro Slim GFCI outdoors or in an unheated space?
Operating range on the SmartlockPro Slim GFCI is -35C to +66C, which covers most unconditioned mechanical rooms, garages, attics and crawl spaces, and outdoor locations in cold climates. The device itself is not a weather enclosure though. Outdoors or in any damp or wet location it has to sit in an appropriate enclosure and cover, and the blank face means you are typically protecting a downstream weather resistant outlet rather than plugging in at this box.
12) My GFCIs keep nuisance tripping near motors and electronics. Will the SmartlockPro Slim be any different?
The SmartlockPro Slim GFCI has improved immunity to high frequency noise specifically to cut nuisance tripping, plus an electronics design that resists electrical surges and over voltages. That is the design answer to a circuit with VFDs, LED drivers, or motor loads on it. It does not change the trip threshold: the device is still Class A at 5mA plus or minus 1mA, so a genuine leakage fault on your circuit will still trip it, and a device that trips repeatedly under load is telling you about the load rather than the GFCI.
13) Can I use the Leviton blank face GFCI to protect a 30 amp or 50 amp circuit?
No. The GFRBF-KW is a 20 amp, 125 volt device and cannot be installed on a circuit above its rating. For higher current single receptacle needs, ZenSupply carries the Pass & Seymour L2130R, a 30A L2130 locking single receptacle, and the Eaton 7379 industrial locking receptacle rated 50A at 600V/250V AC/DC. Neither of those is a GFCI device, so ground fault protection on those circuits has to come from a breaker at the panel.
14) I am standardizing 20 amp white decorator outlets across a building. What pairs with the Leviton blank face GFCI downstream?
Wire the downstream openings with standard decorator receptacles and let the GFRBF-KW protect the run. The Pass & Seymour 26352W is a 20A 125V heavy duty spec grade decorator duplex in white, which matches both the amperage and the white monochromatic finish of the Leviton device, and both take a Decora style plate. For lighter duty interior openings, the Pass & Seymour 3232TRW Trademaster tamper resistant duplex in white is the other white option, and tamper resistant is what dwelling unit openings generally call for.
15) Is the Leviton GFRBF-KW suitable for an industrial or explosionproof environment?
Not for a classified location. The GFRBF-KW has a polycarbonate body with a thermoplastic face and is a general purpose wiring device. Where the area is classified, the device has to be rated for it: Appleton's FSQC Series interlocked explosionproof receptacle is built for that duty, and the Appleton U-Line ECS factory sealed 15 and 20 amp plug and receptacle set covers factory sealed 3-pole applications. For heavy industrial but unclassified areas, Eaton's 5262W is an industrial specification grade duplex and the 6450W is an industrial spec grade decorator single taking #14-10 AWG.
16) Is the Pass & Seymour 3232TRW a substitute for the Leviton GFRBF-KW in a daycare or residential rental?
No. The 3232TRW is a Trademaster tamper-resistant duplex receptacle in white, which addresses child access to the slots, not ground fault current. The Leviton GFRBF-KW is a SmartlockPro Slim GFCI with a Class A 5mA plus or minus 1mA trip level that feeds 20 amp feed-through current to downstream devices. Tamper resistance and GFCI protection are separate requirements, and the 3232TRW answers only the first.
17) Can an Eaton 5262W be used where a Leviton GFRBF-KW is specified?
Not as a like-for-like. The Eaton Arrow Hart 5262W is an industrial specification grade duplex receptacle rated 15A 125V with a 5-15R configuration in gray. The GFRBF-KW is a blank face GFCI carrying 20 amp feed-through current in white, on a NEMA WD-6 and ANSI C-73 device. The 5262W is a 15 amp plug-in face at 125V; the Leviton passes 20 amps through to protected downstream outlets.
18) Which single receptacle works on the same #14-10 AWG wire as the Leviton GFRBF-KW?
The Eaton 6450W is a heavy-duty industrial specification grade decorator single receptacle listed for #14-10 AWG conductors, the same terminal accommodation the GFRBF-KW carries at 14-10 AWG. The Leviton terminates back and side with brass clamps and a self grounding clip; the 6450W is a single decorator face rather than a GFCI device, so it will not provide the Class A trip protection.
19) Will a locking receptacle like the Pass & Seymour L2130R or Eaton 7379 do the same job as the Leviton GFRBF-KW?
No - those are twist-lock devices for cord-connected equipment. The Pass & Seymour L2130R is a 30A L2130 single receptacle in black and the Eaton 7379 is an industrial locking receptacle rated 50A, 600V/250V AC/DC in black, an extra heavy duty grade device. The Leviton GFRBF-KW is a 125 VAC, 2 pole, 3 wire blank face GFCI on a decorator opening, so it neither locks a plug nor serves those higher voltage circuits.
20) Will the Leviton GFRBF-KW hold up to repeated plug cycling and hard tightening on a commercial job?
The contacts and the strap are the parts that matter on a device that gets torqued into a metal box. Line contacts are brass double wipe at .031 thick, the strap is galvanized steel and the yoke is zinc plated steel, and the device is built to withstand high torque and resist wire pullout. Bear in mind the face is blank, so nothing cycles in and out of this device itself. Wear happens at the downstream outlets it protects, and those are what to spec for duty cycle.
21) What is a simpler commercial grade receptacle than the Leviton GFRBF-KW for a general purpose outlet?
The Eaton 816W is a commercial specification grade single receptacle rated 15A. It is a plain single outlet with no ground fault electronics, where the GFRBF-KW is a SmartlockPro Slim GFCI with a 10KA short circuit current rating and a blank face that protects downstream devices. Choose the 816W only where the circuit does not require GFCI protection.
How fast can I get the Leviton GFRBF-KW delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the
continental
U.S.
Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit,
reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Leviton GFRBF-KW come with a warranty?
Absolutely. The Leviton GFRBF-KW is backed by a manufacturer’s warranty.
For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Leviton GFRBF-KW?
You can call, text, or email our expert support team for fast answers. We’re here to help with
product
selection,
installation tips, and troubleshooting. Contact Us
Why buy the Leviton GFRBF-KW from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support,
and
rewards on
every order.
Our team is always ready to help you choose the right product for your project.