ABB 8-Circuit Main Lug 125A Lo...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$315.60

ABB 8-Circuit Main Lug 125A Load Center, Indoor Flush Mount

(No reviews yet) Write a Review

Model: TLM812FCUD

In Stock (leaves warehouse same day if ordered before 3pm ET)

$315.60
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

ABB 8-Circuit Main Lug 125A Load Center, Indoor Flush Mount

The ABB 8-Circuit Main Lug Load Center is a 125A, 120/240V AC, 1 Phase distribution enclosure engineered for indoor flush-mount installation with a hinged door. Configured for 3-wire service and either main or sub-feed applications, this UL-listed load center delivers a 65 kA interrupt rating for dependable overcurrent protection in residential and light commercial electrical systems. The enclosure design suits standard indoor flush wall installations where a clean, code-compliant finish is required.

Key Features

  • Circuit Capacity: 8-circuit main lug configuration for compact branch circuit distribution.
  • Amperage Rating: 125A rated bus for reliable power distribution in residential and commercial applications.
  • Service Voltage: 120/240V AC service voltage for standard single-phase electrical systems.
  • Phase Configuration: 1 Phase design suited to typical residential and light commercial loads.
  • Wiring Configuration: 3 Wire setup for standard split-phase service connections.
  • Interrupt Rating: 65 kA interrupt rating for enhanced short-circuit protection.
  • Mounting Style: Indoor flush enclosure with door for a finished, concealed installation.
  • Feeder Flexibility: Accepts either main or sub-feed configuration for versatile system design.

Certifications & Compliance

  • UL Listed

Technical Specifications

  • Number Of Feeders: Either
  • Interrupt Rating: 65 kA
  • Load Regulation: 120/240V AC
  • Phase: 1 Phase
  • Standard: UL
  • Enclosure: Indoor
  • Wiring Configuration: 3 Wire
  • Amperage Rating: 125 A
  • Packaging: 1 EA

Typical Applications

  • Residential Electrical Service Panels
  • Light Commercial Power Distribution
  • Indoor Flush-Mount Panel Installations
  • Branch Circuit Load Centers
  • Renovation and New Construction Wiring

Why ABB?

ABB engineers its load centers to UL-listed standards with a 65 kA interrupt rating, giving electrical professionals a dependable option for code-compliant power distribution. The indoor flush enclosure with door and flexible main/sub-feed configuration make this ABB load center a practical choice for residential and light commercial installations that demand reliable, long-term performance.

Manufacturer Resources

Product Specs

Product Type:
Load Center
Voltage Rating:
120/240V
Amperage Rating:
125A
Listing:
UL Listed
Configuration:
Indoor Flush Mount with Door
Department:
Electrical
Product Group:
Wiring Devices
Product Subgroup:
Panelboards & Load Centers

ABB TLM812FCUD – Frequently Asked Questions

1) Is the ABB 125A main lug load center suitable for standard residential 120/240V service?
Yes. It is rated 125A at 120/240V AC, single phase, 3 wire, which is the standard split phase residential service arrangement. That covers a typical house subpanel or a small service, plus light commercial branch circuit distribution.
2) Main lug versus main breaker: does this ABB 8-circuit panel have a main disconnect?
No, it is a main lug only panel. Feeders land directly on the lugs, so there is no integral main breaker to shut off the whole panel. That means upstream overcurrent protection has to exist somewhere else, which is why main lug panels are normally used as subpanels fed from a breaker in the upstream board. It is configured to accept either a main or a sub feed.
3) I need an outdoor panel - does the ABB flush mount load center work, or do I need something else?
Do not use the flush indoor version outdoors. The ABB 8-circuit 125A load center is offered two ways: TLM812FCUD as a flush mount indoor NEMA 1 enclosure, and TLM812RCU as a surface mount outdoor NEMA 3R enclosure. For an exterior wall, specify the NEMA 3R surface mount version. The Square D Homeline 225A and QO plug-on neutral main lug load centers are both NEMA 1 enclosures, so neither of those is an outdoor substitute.
4) What is a bigger alternative to the ABB 8-circuit 125A main lug load center for a panel that needs far more branch circuits?
The ABB TLM812 load center is rated 125A at 120/240V and holds 8 circuits, which suits a compact branch distribution or sub-feed panel. When the load schedule outgrows that, the Square D Homeline 60-space 120-circuit 225A convertible main lugs load center in a NEMA 1 enclosure is the step up - it carries a 225A bus, 60 spaces for up to 120 circuits, and converts to a main breaker panel. Both are main lug designs, so the ABB is the choice for a small indoor flush pocket panel and the Homeline for a full service-size panel.
5) If I want plug-on neutral breakers instead, what load center should I use in place of the ABB 125A main lug panel?
The ABB TLM812 is a conventional main lug load center where neutrals land on the neutral bar. If your specification calls for plug-on neutral so AFCI and GFCI breakers snap directly to the neutral bus without a pigtail, the Square D QO convertible main lugs load center is the plug-on neutral option, also in a NEMA 1 enclosure. Both are main lug convertible-style panels for indoor use; the difference is the breaker interface and the QO breaker line it accepts.
6) Will Square D Homeline or QO breakers fit the ABB 8-circuit load center?
No. The ABB TLM812 load center accepts ABB/Thomas & Betts style breakers for its bus; the Square D Homeline 225A main lugs load center and the Square D QO plug-on neutral main lugs load center are built around the Homeline and QO breaker series respectively. Breakers are not interchangeable across these bus designs, so order breakers matched to whichever panel you install rather than assuming a common fit.
7) What does the 65 kA interrupt rating on this ABB load center mean for my install?
The panel carries a 65 kA interrupt rating, so it is suited to installations where the available fault current at the panel location is high, such as a point close to a large service transformer. Confirm the calculated available fault current at your point of installation is at or below that figure. The panel is UL Listed.
8) How many circuits does the ABB TLM812 hold, and what if I need more spaces?
It is an 8-circuit panel, sized for compact branch circuit distribution, a small subpanel, an addition, or a garage feed. For anything larger, look to a higher-space board such as the Square D Homeline 60-space 120-circuit 225A convertible main lugs load center in NEMA 1, or the Square D QO convertible main lugs load center with plug-on neutral.
9) Can I use this ABB panel as a subpanel off my existing main service?
Yes, that is a common use. The panel accepts either a main or sub feed, and because it is main lug only, feeding it from a breaker in the upstream service panel gives it the overcurrent protection it needs. On a subpanel the neutral and ground have to be kept separate per code.
10) Can I use the ABB 8-circuit load center as a service entrance main breaker panel?
The ABB TLM812 is a main lug load center, meaning the feeder lands on lugs and overcurrent protection comes from an upstream device; it is configured to serve as either a main or sub-feed panel. If you need a panel that can be field-converted to accept a main breaker, both Square D comparables are convertible main lugs designs - the Homeline 225A 60-space and the QO plug-on neutral - and convert to main breaker configuration with the appropriate kit.
11) Does the flush mount version of this ABB load center come with a door?
Yes. The indoor flush mount configuration is supplied with a hinged door, so the panel finishes flush in the wall with the interior concealed behind the cover.
How fast can I get the ABB TLM812FCUD delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the ABB TLM812FCUD come with a warranty?
Absolutely. The ABB TLM812FCUD is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the ABB TLM812FCUD?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the ABB TLM812FCUD from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.