B-Line Eaton series open rack...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$1,857.50
Image coming soon

B-Line Eaton series open racks, 72.625" height, 7" length, 10" width, Aluminum, RCM rack mounted vertical cable manager single sided, Direct pdu moun

(No reviews yet) Write a Review

Model: SB862810S078FB

In Stock (leaves warehouse same day if ordered before 3pm ET)

$1,857.50
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks
Eaton B-Line series open frame racks, 72.625" height, 7" length, 10" width, Aluminum, RCM rack mounted vertical cable manager single sided, Direct pdu mounting, Low density plastic gate, Flat black powder coat

Manufacturer Resources

Product Specs

Application:
Designed for routing cabling on and between racks
Certifications:
UL
Material Details:
Flat black powder coat, black plastic components
Mounting Method:
Direct PDU mounting
Product Height:
72.625 in
Product Length Depth:
7 in
Product Weight:
10.8 lb
Product Width:
10 in
Special Features:
Includes vertical cable section, push in fastener
Department:
Electrical
Product Model:
RCM rack mounted vertical cable manager single sided
Product Color:
Black
Product Style:
Low density plastic gate
Product Material:
Aluminum

B-LINE SB862810S078FB – Frequently Asked Questions

1) Will the Eaton B-Line SB862810S078FB vertical cable manager fit a 7-foot open frame rack?
The manager stands 72.625 inches tall, which lines up with a standard 7-foot (84 inch) open frame rack and leaves room at the top and bottom for the rack's own framing. It is a vertical section that mounts alongside the rack uprights rather than occupying rack units, so it does not consume any of your usable RU space.
2) How much side clearance do I need between racks for this B-Line cable manager?
Plan on 10 inches of width and 7 inches of depth for the channel body, SB862810S078FB measures 10 inches wide by 7 inches front to back. In a row of bayed open frame racks that width sits between or outboard of the uprights, so it needs to be accounted for in your total row length and in aisle-width calculations.
3) Is this a single-sided or double-sided cable manager?
Single sided. The RCM vertical manager routes and retains cable on one face only, so it is the choice for the end of a row or where you only need to dress cable on the front of the rack. If you are running both front and rear cabling in the same channel, a single-sided section will not cover the back side.
4) Can I mount a vertical PDU in this B-Line manager?
Yes, it is built for direct PDU mounting, so a vertical rack PDU fastens into the channel itself instead of eating rack units or needing a separate PDU bracket. That is the main reason to pick this version over a plain cable-only channel in a rack that is running a 0U vertical strip.
5) What kind of door or gate does this manager use to hold cable in?
It uses a low density plastic gate rather than a hinged metal cover. The gates flex open for adding or pulling a cable without removing hardware, and hold the bundle in place once released. Good for data center rows where moves and changes are frequent; if you need a lockable or fully enclosing metal door, this is not that style.
6) What is included with the SB862810S078FB, and do I need extra hardware to attach it?
The assembly ships with the vertical cable section and push in fasteners, so the cable retention hardware is in the box. Anything beyond that, rack-to-rack baying hardware or the PDU itself, is a separate order.
7) Is this B-Line vertical cable manager UL listed for a data center or institutional install?
UL is the certification carried on the SB862810S078FB vertical manager, which is typically what a facilities or institutional spec calls for on rack-mounted cable management. The finish is flat black throughout to match standard black open frame racks.
8) Do I need one of these per rack or one between each pair of racks?
Because this is a single-sided channel designed for routing cabling on and between racks, most rows use one section per rack bay plus one on the end of the row. If your cable volume is heavy on both front and rear, count on separate sections rather than expecting one single-sided manager to serve two directions.
9) Is this cable manager aluminum or steel, and what is the finish?
Body is aluminum with a flat black powder coat, and the gates and trim are black plastic. The aluminum keeps the weight down at 10.8 lb for a full 72.625 inch section, which matters when one tech is hanging it on a standing rack.
How fast can I get the B-LINE SB862810S078FB delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the B-LINE SB862810S078FB come with a warranty?
Absolutely. The B-LINE SB862810S078FB is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the B-LINE SB862810S078FB?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the B-LINE SB862810S078FB from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.