- Amperage Rating:
- 840A
- Connector Material:
- Aluminum
- Line:
- (2) #600-2 Cu/Al
- Load:
- (4) #3/0-8Cu/Al, (4) #4-14Cu/8 Al
- Number Of Poles:
- Three-pole
- Operating Temperature:
- 150°C
- Voltage Rating:
- 600V
- Department:
- Electrical
- Product Type:
- CH165
- Product Details:
- CH165
B-LINE CH16528-3 – Frequently Asked Questions
1) What wire sizes can I land on the B-Line CH16528-3 power distribution block?
The CH16528-3 takes two line conductors per pole at #600-2 Cu/Al, and on the load side four #3/0-8 Cu/Al plus four #4-14 Cu (or #8 Al) per pole. So you can feed it with large service conductors and tap off eight branch conductors per pole in two size ranges. Lugs are aluminum bodied, rated for both copper and aluminum conductors.
2) Is the CH16528-3 terminal block rated for a 600V three-phase system?
Yes. It is a three-pole block rated 600V, so it suits 600V and below three-phase distribution, including 480Y/277 and 208Y/120 systems. Each of the three poles is independent, with its own line and load terminations.
3) How much current will the B-Line CH16528-3 distribution block carry?
It is rated 840A. That is the block rating, so the feeder and the sum of the taps you land on it have to sit inside that figure, and each individual conductor is still limited by its own ampacity and the lug range it fits.
4) Can I use aluminum feeders on this B-Line power distribution block, or copper only?
Both. The connectors are aluminum bodied and dual rated Cu/Al across the line and load ranges, so aluminum feeder into the line side and copper branch conductors on the load side is a normal arrangement. One exception to watch: the smaller load position is #4-14 in copper but only #8 in aluminum.
5) I need to split one large feeder into several branch circuits in a panel. Is this the right part?
That is exactly what a power distribution block does, and the CH16528-3 is built for it: two line conductors in per pole up to #600, then eight load terminations per pole to feed the branches. It is not a breaker and provides no overcurrent protection, so each tap still needs its own protective device per the design.
6) What temperature is the CH16528-3 block rated for in a hot switchgear enclosure?
Operating temperature is rated to 150 degrees C, which covers the ambient plus rise you see inside a loaded gear section or a rooftop enclosure. Conductor insulation temperature rating and the terminal's listed conductor temperature still govern your ampacity calculation.
How fast can I get the B-LINE CH16528-3 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the
continental
U.S.
Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit,
reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the B-LINE CH16528-3 come with a warranty?
Absolutely. The B-LINE CH16528-3 is backed by a manufacturer’s warranty.
For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the B-LINE CH16528-3?
You can call, text, or email our expert support team for fast answers. We’re here to help with
product
selection,
installation tips, and troubleshooting. Contact Us
Why buy the B-LINE CH16528-3 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support,
and
rewards on
every order.
Our team is always ready to help you choose the right product for your project.