Burndy 2 AWG Copper 1-Hole Com...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$3.43

Burndy 2 AWG Copper 1-Hole Compression Lug

(No reviews yet) Write a Review

Model: YA2CLBOX

In Stock (leaves warehouse same day if ordered before 3pm ET)

$3.43
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Burndy YA2CL6BOX 2 AWG Copper 1-Hole Compression Lug, 1/2" Stud

The Burndy YA2CL6BOX is a 2 AWG copper, 1-hole compression lug from Burndy's HYLUG™ line, featuring a 1/2" stud size and standard barrel construction. Built for compression termination of code conductors, it includes an inspection window and internal chamfer to verify proper conductor insertion, plus a tin-plated finish for corrosion resistance. This BROWN color-coded terminal is UL/CSA rated 90° up to 35kV and sized for die index 10 crimping tools, delivering secure, code-compliant electrical connections.

Key Features

  • Stud & Hole Size: 1/2" stud size with a 0.53" hole diameter for secure hardware mounting.
  • 1-Hole Mounting: single mounting hole with a 0.73" pad width for standard busbar and pad connections.
  • Durable Construction: copper body with a tin-plated finish for strong conductivity and corrosion resistance.
  • Compression Termination: standard barrel design with inspection window and internal chamfer, sized to die index 10 for verified, code-compliant crimp connections.
  • Conductor Range: engineered for 2 AWG copper conductors (60 (37) Navy stranding) with a 15/16" strip length and 2.30" overall length.
  • Voltage & Temperature Rating: UL/CSA rated 90° up to 35kV, minimum voltage rating of 600V, and a 194° temperature rating.
  • Color Code: BROWN color coding for quick die and size identification.

Certifications & Compliance

  • UL Listed
  • CSA Approved
  • UL/CSA Rated 90° Up to 35kV

Technical Specifications

  • Mounting Holes: 1
  • Product Material: Copper
  • Termination Method: Compression
  • Rating - KVA: 35 kV
  • Voltage - Maximum: 35000
  • UL Listed: Yes
  • Certification - CSA Approved: Yes
  • Dimension - Pad Width inch: 0.73 in
  • Dimension - Hole Size inch: 0.53 in
  • Dimension - Stud Size inch: 1/2
  • Dimension - Strip Length inch: 15/16
  • Dimension - Length Overall inch: 2.30 in
  • Conductor - Copper Str Navy Size Range: 60 (37) Navy
  • Temperature Rating: 194
  • Die Index: 10
  • Minimum Pack Quantity: 1
  • Application: For Code Conductor
  • Product Type: Terminal
  • Plating Type: Tin - Electro Plated
  • Trade Name: HYLUG™
  • UPC: 781810552100

Typical Applications

  • Copper Conductor Terminations in Electrical Panels and Switchgear
  • Grounding and Bonding Connections
  • Industrial and Commercial Power Distribution Systems
  • Code Conductor Terminations up to 35kV
  • Compression Lug Connections for Busbars and Pads

Why Burndy?

Burndy is a recognized manufacturer of compression connectors and terminals for the electrical industry, and the YA2CL6BOX HYLUG™ terminal reflects that standard with tin-plated copper construction, an inspection window for connection verification, and an internal chamfer for proper conductor seating. Backed by UL/CSA listing rated 90° up to 35kV and precise die index 10 sizing, this lug delivers dependable, code-compliant compression terminations for demanding electrical applications requiring verified conductor insertion and long-term connection reliability.

Product Specs

Trade Name:
HYLUG™
Termination Method:
Compression
Physical Attribute - Tongue Angle:
Straight
Conductor - Copper Str Size:
2 AWG
Plating Type:
Tin - Electro Plated
Physical Attribute - Tongue Type:
Standard
Die Index:
10
Product Material:
Copper
Insulated:
Yes
UL Listed:
Yes
Dimension - Outside Diameter inch:
0.42 in
Physical Attribute - Number of Holes:
1
Certification - cULus:
No
Wire Size:
2 AWG
Product Details:
Standard Barrel, Tin Plated
Temperature Rating:
194
Standards - RoHS Compliance Status:
CM
Color Code:
Brown
Connector Type:
STANDARD BARREL
Dimension - Strip Length inch:
15/16
Dimension - B Length inch:
0.88 in
Certification - ETL:
No
Certification - CSA Approved:
Yes
Feature - Barrel Type:
Standard
Minimum Pack Quantity:
1
Mounting Holes:
1
list_batch:
BURNDY-20260915
Voltage - Maximum:
35000
Conductor - Copper Str Navy Size:
60 (37) Navy
Product Type:
Compression Lug
Certification - UL Recognized:
No
Rating - KVA:
35 kV
Plating:
Tin Plated
Rating - Minimum Voltage:
600
Department:
Electrical
Product Group:
Wire Connectors & Terminals
Product Subgroup:
Lugs & Terminals
Sub Brand:
HYLUG
Conductor - Copper Str Navy Size Range:
60 (37) Navy
Plated:
Y
Conductor - Material:
Copper
Application:
For Code Conductor

Burndy YA2CLBOX – Frequently Asked Questions

1) Which stud sizes does the Burndy YA2CL 2 AWG copper compression lug come in?
Two stud sizes: a 1/2 inch stud version (YA2CL6BOX) and a 5/16 inch stud version (YA2CLBOX). Both are 2 AWG copper, one-hole, straight tongue lugs from the HYLUG line. Match the stud size to the bolt on your busbar or equipment pad, because the bolt hole is sized to the stud and is not interchangeable between the two.
2) What crimp die do I need for a Burndy YA2CL lug?
Die index 10. The lug is color coded brown, which is Burndy's quick visual match between the lug and the correct die on the tool. Crimp it with a compression tool set to index 10 and verify the conductor through the inspection window before you crimp.
3) How much insulation do I strip back for a 2 AWG Burndy compression lug?
Strip 15/16 inch. That fills the standard barrel to the internal chamfer so the strands seat fully, and you can confirm it visually through the inspection window before crimping. The barrel outside diameter is 0.42 inch and barrel length is 0.88 inch.
4) Will a Burndy YA2CL lug work on aluminum conductor?
No. It is a copper-bodied lug specified for 2 AWG copper code conductor, including 60 (37) Navy stranding. For aluminum or dual-rated AL9CU service you need a lug listed for aluminum; putting bare aluminum into a copper-only barrel is a dissimilar metal connection and is not what this part is listed for.
5) Will the 1/2 inch stud version bolt to my equipment pad?
The 1/2 inch stud lug has a 0.53 inch bolt hole on a 0.73 inch pad width, overall length 2.30 inch, with a single straight tongue. So it takes 1/2 inch hardware and needs a landing pad at least as wide as 0.73 inch. If your pad is drilled for 5/16 inch bolts, order YA2CLBOX instead.
6) Can I use a compression lug like this for grounding and bonding?
Yes, that is one of its normal uses. A one-hole copper compression lug terminates 2 AWG copper ground or bonding conductor onto a ground bar or equipment pad, and the crimped barrel gives a permanent connection rather than a set screw that can loosen. Pick the stud size to match the ground bar hardware, 1/2 inch or 5/16 inch.
7) Is this lug corrosion resistant enough for outdoor or damp electrical rooms?
The copper body is electro tin plated, which is the standard finish for resisting corrosion and oxidation at the connection. Tin plating also keeps the copper from oxidizing where it bolts to a plated busbar. It is a standard barrel, non-insulated-body compression lug, so in wet or outdoor locations you still need appropriate enclosure and taping or heat shrink per the application.
8) Do I have to buy these Burndy lugs in a box quantity?
No. Minimum pack quantity is 1, so you can order a single lug for a one-off termination or buy in bulk for a panel job.
How fast can I get the Burndy YA2CLBOX delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Burndy YA2CLBOX come with a warranty?
Absolutely. The Burndy YA2CLBOX is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Burndy YA2CLBOX?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Burndy YA2CLBOX from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.