Burndy YA2C2LN 2 AWG Copper 2-...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$4.90

Burndy YA2C2LN 2 AWG Copper 2-Hole Compression Lug, Tin Plated

(No reviews yet) Write a Review

Model: YA2C2LN

In Stock (leaves warehouse same day if ordered before 3pm ET)

$4.90
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Burndy YA2C2LN 2 AWG Copper 2-Hole Compression Lug, Tin Plated

The Burndy YA2C2LN is a 2 AWG copper compression lug engineered for secure, code-compliant terminations in panel and switchgear applications. This HYLUG™ connector features a 2-hole mounting pad on 1.75" spacing and is available with a stud size of 1/2" or 3/8" depending on the option selected, giving installers flexibility to match existing hardware without switching connector families. The standard barrel is skived and chamfered for easy conductor entry during crimping, and every lug in this family carries a tin-plated (electro-plated) finish for corrosion resistance. Rated 90°C with a voltage rating up to 35kV and a 600V minimum rating, this connector is built to UL/CSA construction standards for reliable code conductor applications.

Key Features

  • Conductor Size: Designed for 2 AWG copper conductors.
  • Copper Construction: Solid copper body with a tin-plated, electro-plated finish for corrosion resistance.
  • 2-Hole Mounting Pad: Two mounting holes on 1.75" spacing, available with a 1/2" or 3/8" stud size to suit the installation.
  • Standard Barrel Design: Chamfered, skived barrel entry with a straight tongue simplifies conductor insertion during crimping.
  • Voltage & Temperature Rating: Rated up to 35kV with a 600V minimum rating and 90°C operating temperature.
  • Termination Method: Compression termination for a secure, permanent mechanical and electrical connection.
  • Die Index 10: Color-coded Brown for quick identification of the correct compression die.
  • Application: Engineered for code conductor terminations using compression tooling.

Certifications & Compliance

  • CSA Approved
  • Built to UL/CSA electrical construction standards

Technical Specifications

  • Mounting Holes: 2
  • Product Material: Copper
  • Termination Method: Compression
  • Insulated: Yes
  • Connector Type: Standard Barrel
  • Product Details: Standard Barrel, Tin Plated
  • Physical Attribute - Tongue Angle: Straight
  • Feature - Barrel Style: Chamfered
  • Outside Diameter: 0.42 in
  • Plating Type: Tin - Electro Plated
  • Stud Size: 1/2 in or 3/8 in
  • Trade Name: HYLUG™
  • Dimension - Pad Width inch: 0.83 in
  • Dimension - Strip Length inch: 15/16
  • Dimension - B Length inch: 7/8 in
  • Rating - KVA: 35 kV
  • Rating - Minimum Voltage: 600
  • Product Type: Terminal
  • Certification - CSA Approved: Yes
  • Die Index: 10

Typical Applications

  • Electrical Panel and Switchgear Terminations
  • Grounding and Bonding of Copper Conductors
  • Industrial and Commercial Power Distribution
  • Code Conductor Compression Connections

Why Burndy?

Burndy's YA2C2LN HYLUG™ family is manufactured from copper with a tin-plated finish and a skived, chamfered barrel for dependable compression terminations, available with either a 1/2" or 3/8" stud to match your hardware. Backed by CSA approval and built to UL/CSA construction standards, it delivers consistent, code-compliant performance for professional electrical installations.

Manufacturer Resources

Product Specs

Wire Size:
2 AWG
Mounting Holes:
2
Plating:
Tin Plated
Termination Method:
Compression
Insulated:
Yes
Dimension - L Length Overall mm:
108 mm
Certification - ETL:
No
Connector Type:
STANDARD BARREL
Product Details:
Standard Barrel, Tin Plated
Physical Attribute - Tongue Angle:
Straight
Conductor - Copper Str Size:
2 AWG
Feature - Barrel Style:
Chamfered
Color Code:
Brown
Outside Diameter:
0.42 in
Physical Attribute - Tongue Type:
Standard
Dimension - Hole Size mm:
14 mm
Dimension - D inch:
3.02 in
Plating Type:
Tin - Electro Plated
Dimension - Z inch:
0.64 in
Dimension - B Length inch:
0.88 in
Dimension - Outside Diameter inch:
0.42 in
Product Bolt Size:
1/2 in
Conductor - Copper Str Navy Size:
60 (37) Navy
Trade Name:
HYLUG™
Feature - Barrel Type:
Standard
Voltage - Maximum:
35000
Standards - RoHS Compliance Status:
CM
Dimension - N inch:
0.63 in
Rating - KVA:
35 kV
UPC:
781810500767
Rating - Minimum Voltage:
600
Sub Brand:
HYLUG
Conductor - Material:
Copper
Dimension - Stud Size inch:
1/2
Conductor - Copper Str Navy Size Range:
60 (37) Navy
Dimension - Pad Width inch:
0.83 in
Dimension - Strip Length inch:
15/16
Dimension - B Length fraction:
7/8 in
Product Type:
Terminal
Certification - cULus:
No
Certification - CSA Approved:
Yes
Application:
For Code Conductor
Die Index:
10
Physical Attribute - Number of Holes:
2
Conductor - Copper Str Size Range:
2 AWG
Plated:
Y
Product Length:
4.27 in
list_batch:
BUR-20260916
Product Material:
Copper
Product Size:
3/8"
Product Size:
1/2"
Finish:
Tin Plated
Connection Type:
Compression
Trade Size:
3/8" - 1/2"
Voltage Rating:
35kV
Listing:
CSA Approved
Department:
Electrical
Product Subgroup:
Lugs & Terminals
Product Group:
Wire Connectors & Terminals

Burndy YA2C2LN – Frequently Asked Questions

1) What die index do I set my crimper to for a Burndy YA2C2LN 2 AWG copper lug?
Die index 10, color coded Brown. Set that die in your compression tool before crimping the 2 AWG copper conductor into the barrel. The brown color code is the quick visual check on the die and the lug so a crew doesn't crimp with the wrong index.
2) Is the YA2C2LN sized for a 3/8 inch or a 1/2 inch stud?
Both are offered, and they are different part numbers. Order the 1/2 inch size for YA2C2LN, or the 3/8 inch size for YA28TC38. Same 2 AWG copper barrel either way, so pick by the bolt already in your bus or breaker pad rather than changing connector families.
3) How far apart are the two mounting holes on this Burndy 2 AWG two-hole lug?
Two mounting holes on 1.75 inch centers, with a pad width of 0.83 inch. That is the standard NEMA two-hole pattern, so it lands on a bus bar or equipment pad drilled for 1.75 inch spacing. Check your pad has 0.83 inch of clear width for the tongue.
4) How much insulation do I strip off 2 AWG before crimping this lug?
Strip 15/16 inch. The barrel bore is 0.42 inch outside diameter and the entry is skived and chamfered, so the stranded 2 AWG copper feeds in without birdcaging once the strip length is right. Barrel length is 7/8 inch, which is why the strip is slightly longer than the barrel itself.
5) Can I use this lug on aluminum conductor?
No. The YA2C2LN is a copper-bodied lug specified for 2 AWG copper conductor only. For aluminum or a dual-rated run you need an AL9CU listed connector instead. Using a copper-only lug on aluminum risks a bad termination and is outside what this part is rated for.
6) What voltage and temperature is this Burndy HYLUG rated for?
Rated to 35kV maximum with a 600V minimum rating, and good for 90 degrees C conductor temperature. That covers 600V panel and switchgear work as well as medium-voltage terminations up to 35kV, so the same lug serves both jobs.
7) Is this lug approved for Canadian work?
CSA approved, and built to UL/CSA electrical construction standards. Note it does not carry a cULus or ETL mark, so if your spec or AHJ demands a UL listing mark specifically rather than CSA, confirm that before you commit the run.
8) Is the tongue straight or offset, and how long is the whole lug?
Straight tongue, standard type, on a standard barrel. Overall length is 4.27 inches, about 108 mm. If your gutter or termination compartment is tight behind the bus, measure that 4.27 inches plus the bend radius of the 2 AWG before you order; an angled-tongue lug is the answer when the conductor has to turn.
9) What size bolt hole are the pad holes drilled for on the 1/2 inch version?
The pad holes measure 14 mm, which is the clearance hole for 1/2 inch hardware. So the 1/2 inch size takes 1/2 inch bolts or studs through the pad. If your equipment lands on 3/8 inch hardware, order the 3/8 inch size (YA28TC38) rather than drilling this pad out.
10) Can I use this for grounding and bonding a 2 AWG copper ground conductor?
Yes. Compression is a permanent mechanical and electrical termination, and the two-hole pad on 1.75 inch centers keeps a ground lug from rotating on the bus, which is exactly why two-hole pads are specified for grounding and bonding. Crimp with die index 10 on 2 AWG copper.
11) Will the tin plating hold up in a damp or outdoor enclosure?
The copper body is electro tin plated for corrosion resistance, which is the usual choice for exterior enclosures, damp locations and anywhere you are bolting copper to a dissimilar metal pad. Plating also keeps the bolted joint surface cleaner over time than bare copper.
How fast can I get the Burndy YA2C2LN delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Burndy YA2C2LN come with a warranty?
Absolutely. The Burndy YA2C2LN is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Burndy YA2C2LN?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Burndy YA2C2LN from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.