Bussmann KLM Series Fast-Actin...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$79.83

Bussmann KLM Series Fast-Acting Fuse

(No reviews yet) Write a Review

Model: KLM-2

In Stock (leaves warehouse same day if ordered before 3pm ET)

$79.83
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Bussmann KLM-8 Fast-Acting Ferrule Fuse, 600 Vac, 8A, 100 kAIC

This Bussmann fuse is part of the Eaton Bussmann series KLM fuse line, engineered to deliver reliable overcurrent protection for demanding electrical systems. This fast-acting, non-indicating fuse is dual-rated at 600 Vac and 600 Vdc, carries an 8A amperage rating, and offers a high interrupting capacity of 100 kAIC at 600 Vac and 50 kAIC at 600 Vdc. The fuse features ferrule end x ferrule end termination housed in a melamine tube body, with nickel-plated bronze ferrule ends providing durable, corrosion-resistant electrical contact. Designed for both AC and DC circuit protection, this fuse is well suited to industrial and commercial electrical applications where dependable, code-compliant performance is required. Its compact ferrule construction allows for straightforward installation in compatible fuse holders and blocks across a range of equipment.

Key Features

  • Amperage Rating: 8A fast-acting fuse element sized for precise overcurrent protection in low-amperage branch circuits.
  • Dual Voltage Rating: Rated 600 Vac and 600 Vdc, making this fuse suitable for both alternating current and direct current circuit applications.
  • High Interrupting Capacity: 100 kAIC at 600 Vac and 50 kAIC at 600 Vdc, providing dependable protection even in high fault-current environments.
  • Fast-Acting Response: Non-time-delay, fast-acting design clears short-circuit and overcurrent conditions quickly to help protect connected equipment.
  • Non-Indicating Design: Standard non-indicating construction delivers straightforward, cost-effective circuit protection without a blown-fuse indicator.
  • Ferrule End x Ferrule End Termination: Ferrule-to-ferrule configuration simplifies installation and replacement in compatible fuse holders, blocks, and disconnects.
  • Melamine Tube Body: Melamine tube construction provides a durable, electrically insulated housing that protects the internal fuse element.
  • Nickel-Plated Bronze Ferrules: Nickel-plated bronze ferrule ends resist corrosion and help maintain dependable, long-term electrical contact.

Technical Specifications

  • Refer to manufacturer documentation for complete technical specifications.

Typical Applications

  • Branch Circuit Overcurrent Protection
  • Industrial and Commercial Electrical Systems
  • Motor Control and Distribution Equipment
  • Panelboard and Switchgear Protection
  • AC and DC Circuit Protection Applications
  • Equipment and Component-Level Fuse Protection

Why Bussmann?

Bussmann fuses are engineered with rugged materials, including nickel-plated bronze ferrules and durable melamine tube bodies, to withstand demanding electrical environments. This fuse's high interrupting ratings of 100 kAIC at 600 Vac and 50 kAIC at 600 Vdc reflect the engineering standards behind the Eaton Bussmann series KLM line. As part of a well-established fuse family, this fuse combines fast-acting protection with dual AC/DC voltage ratings in a compact ferrule format. Choose Bussmann for dependable, code-compliant overcurrent protection on professional electrical projects.

Manufacturer Resources

Product Specs

Product Type:
Fast-Acting Fuse
Department:
Electrical
Product Group:
Circuit Protection
Product Subgroup:
Fuses
Product Height:
0.001 in
Product Width:
0.001 in
Product Length:
0.001 in
Product Weight:
0.18 lb

Bussmann KLM-2 – Frequently Asked Questions

1) What amp ratings does the Bussmann KLM fuse come in?
The KLM Series is offered in 2A, 5A, 6A, 8A and 20A, ordered as KLM-2, KLM-5, KLM-6, KLM-8 and KLM-20. All of them share the same 600 Vac / 600 Vdc dual rating, so you pick purely on the amperage your circuit needs.
2) Can I use a KLM fuse on a DC circuit, not just AC?
Yes, the KLM is dual rated 600 Vac and 600 Vdc. Interrupting capacity differs between the two: 100 kAIC at 600 Vac and 50 kAIC at 600 Vdc. If you are protecting a DC bus, size your available fault current against the 50 kAIC figure.
3) Is the KLM a time-delay fuse or fast-acting?
Fast-acting, non-time-delay. It clears short circuits and overcurrents quickly, which suits electronics, control circuits and equipment-level protection. If you are feeding a motor or a transformer with a heavy inrush, a fast-acting element will nuisance-open on startup, so a time-delay class fuse is the right choice there instead.
4) Will a KLM fuse fit my existing fuse holder?
The KLM has ferrule end by ferrule end termination, so it drops into ferrule-style fuse holders, blocks and disconnects rather than blade or bolt-down mountings. Ferrule fuses are held by clip or clamp contact, so match your holder's clip length and the fuse's diameter before ordering.
5) Does the KLM fuse show when it has blown?
No. The KLM is a non-indicating fuse, with no blown-fuse indicator pin or window. Troubleshooting means pulling the fuse and checking continuity, or relying on an indicating fuse holder. If a technician needs to see a blown fuse at a glance in a panel, specify an indicating type instead.
6) Is a 100 kAIC fuse overkill for a commercial panel?
Not usually. The 100 kAIC rating at 600 Vac is what lets the fuse be applied on services where available fault current is high, which is common downstream of large commercial transformers. Your fuse interrupting rating has to equal or exceed the available fault current at that point in the system, so a high AIC gives you headroom rather than a problem.
7) What is the KLM fuse body made of, and will it hold up in a dirty industrial enclosure?
The body is a melamine tube, an insulating material that handles the heat and mechanical abuse of industrial service, and the ferrule ends are nickel-plated bronze. The nickel plating is the part that matters for long-term reliability in damp or dusty gear, since corroded ferrules mean high-resistance contact and heat at the clips.
8) Where are KLM fuses typically used on an MRO parts shelf?
Common uses are branch circuit overcurrent protection, motor control and distribution equipment, panelboard and switchgear protection, and component-level protection inside equipment. Because the low ratings (2A through 20A) all share the same 600 V dual rating and ferrule format, facilities often stock the full amp range as one line item family for control panel repairs.
How fast can I get the Bussmann KLM-2 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Bussmann KLM-2 come with a warranty?
Absolutely. The Bussmann KLM-2 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Bussmann KLM-2?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Bussmann KLM-2 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.