Command Access CYREXKIT-ED Fie...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$95.22
$55.62

Command Access CYREXKIT-ED Field REX Kit for Corbin 5000/Yale 7000 Exit Devices with 5A Rating

(No reviews yet) Write a Review

Model: CYREXKIT-ED

In Stock (leaves warehouse same day if ordered before 3pm ET)

$95.22
$55.62
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Command Access Field REX Kit for Corbin 5000/Yale 7000 Exit Devices with 5A Rating

Professional Request to Exit Switch Solution

The Command Access CYREXKIT-ED provides field-installable request to exit functionality for mechanical Corbin ED4000/5000 and Yale 7000 exit devices. This complete kit features a 5A @120VAC rated switch with three-wire configuration including common, normally open, and normally closed contacts. The kit includes all necessary mounting hardware and installation accessories for professional integration with existing exit device systems.

Professional Features & Benefits

  • High-Current Rating: 5A @120VAC capacity handles demanding electrical loads for reliable switching performance in commercial applications.
  • Universal Exit Device Compatibility: Designed specifically for Corbin ED4000/5000 and Yale 7000 series exit devices for seamless integration.
  • Three-Wire Configuration: Green common, blue normally open, and gray normally closed connections provide flexible wiring options for various control systems.
  • Complete Installation Kit: Includes REX switch, Phillips screws, REX sticker, cable tie, and cable tie mount for professional field installation.
  • Field-Installable Design: Retrofit capability allows addition of REX functionality to existing mechanical exit devices without device replacement.
  • Professional Identification: Included REX sticker provides clear marking for code compliance and user identification.

Technical Specifications

  • Commercial/Residential: Commercial
  • Department: Door Hardware
  • Electronic: Yes
  • Parts and Accessories Type: Replacement Parts
  • Product Attribute: Parts and Accessories
  • Product Category: Electronic Access Controls
  • Product Group: Electronic Access Controls
  • Product Subgroup: Sensors, Switches, Relays and Timers
  • Product Type: Parts and Accessories
  • Series: CYREXKIT-ED Switch kits
  • Subcategory: Accessories

Professional Applications

  • Commercial Building Security Systems
  • Retail Loss Prevention
  • Healthcare Facility Access Control
  • Educational Institution Safety Systems
  • Industrial Facility Monitoring
  • Emergency Exit Compliance
  • Government and Municipal Buildings

Why Choose Command Access Quality?

Command Access electronic access control components deliver professional-grade reliability with 5A @120VAC rated switching capacity for demanding commercial applications. The complete kit design with all necessary mounting hardware ensures proper installation and long-term performance. Engineered for demanding commercial applications where dependable exit control functionality is essential.

Manufacturer Resources

Product Specs

Product Group:
Electronic Access Controls
Series:
CYREXKIT-ED Switch kits
Product Subgroup:
Sensors, Switches, Relays and Timers
Product Type:
Parts and Accessories
Subcategory:
Accessories
Commercial/Residential:
Commercial
Electronic:
Yes
Parts and Accessories Type:
Replacement Parts
Product Attribute:
Parts and Accessories
Product Category:
Electronic Access Controls
Department:
Door Hardware

Command Access CYREXKIT-ED – Frequently Asked Questions

1) Will the Command Access CYREXKIT-ED work on a Corbin Russwin ED4000 exit device?
Yes. The CYREXKIT-ED is built for mechanical Corbin ED4000/5000 and Yale 7000 series exit devices. Those are the devices it's cut to fit. If your opening has a different device, a Von Duprin 99 or a Precision 2000 for example, this kit won't mount to it.
2) Can I add request-to-exit to an existing mechanical exit device without replacing the whole device?
That's exactly what the CYREXKIT-ED is for. It's a field-installable REX switch kit that adds request-to-exit signalling to a mechanical Corbin ED4000/5000 or Yale 7000 device already hung on the door, so you keep the existing exit device and the existing prep. No device swap, no new door prep.
3) How do I wire the Command Access CYREXKIT-ED REX switch into an access control panel?
Three wires: green is common, blue is normally open, gray is normally closed. Pick NO or NC depending on what your panel or alarm shunt input expects, and cap the leg you don't use. Having both contacts on the same switch means one kit covers either convention.
4) What comes in the Command Access CYREXKIT-ED kit, and what do I still need to supply?
The kit ships with the REX switch, Phillips mounting screws, a REX sticker, a cable tie and a cable tie mount. That covers the mechanical install inside the device. You supply the wire run, the door loop or electric hinge transfer to get the three conductors off the door, and whatever panel or relay the contacts report to.
5) I am standardizing REX switches across a building with mixed exit device brands. Will one CYREXKIT-ED part number cover them all?
No. This kit covers Corbin ED4000/5000 and Yale 7000 devices only. On a mixed-brand building you'll need a different REX solution for the openings running other manufacturers' devices. Survey the devices first, count the Corbin and Yale openings, and order CYREXKIT-ED against that count rather than against the total door count.
6) If the exit device is not a Corbin ED4000/5000 or Yale 7000, what else gives a request to exit signal at that door?
The Command Access CYREXKIT-ED is a field-installable REX switch kit built specifically for mechanical Corbin ED4000/5000 and Yale 7000 exit devices, so on other exit hardware the signal usually has to come from the door rather than from inside the device. The DynaLock 6451 series exit sensor bar for a 36 inch door is the other common approach: it senses egress at the bar itself instead of being fitted into a particular manufacturer's exit device chassis, which is what you reach for when the device on the opening is not one the CYREXKIT-ED is cut for. A security integrator standardizing REX across a mixed-hardware building will typically use the kit where the Corbin or Yale devices are and the sensor bar elsewhere.
7) Is a delayed egress sounder the same thing as a REX switch kit?
No, and they are not interchangeable. The Command Access CYREXKIT-ED is a request to exit switch kit with common, normally open and normally closed contacts, rated 5A at 120VAC, that tells the access control system someone is legitimately leaving so the door is not reported as forced. The RCI 914 series delayed egress sounder is an annunciating device with field-selectable volume output up to 102dB, whose job is to sound at the opening during the egress delay. On a delayed egress opening you often have both: the sounder handles the audible side and the REX contact handles the signal back to the panel. Buying the sounder in place of the kit leaves the panel without a REX input.
8) What is the contact rating on the Command Access CYREXKIT-ED REX switch?
5A at 120VAC. That's a line-voltage-capable contact, so the switch can break a load directly rather than only feeding a low-voltage panel input, which matters if you're shunting an alarm circuit or driving something heavier than a dry-contact input.
9) Do I need to run power to the door for the CYREXKIT-ED REX switch?
Not for the switch itself. A REX kit like this is a mechanical switch actuated by the push bar, and it just closes or opens a contact. You do have to get three conductors from the device out through the door, so plan on a door cord or an electric transfer hinge. That's the wiring path, not a power supply for the kit.
10) What is the difference between a REX switch kit and a delayed egress sounder or exit sensor bar?
A REX kit signals your access control system that someone pushed the bar, so the system can shunt a door alarm or unlock a companion device. It doesn't sound, delay, or restrict egress. If you need an audible on the opening, that's a delayed egress sounder like the RCI 914 Series, which has field-selectable volume up to 102dB. If you need touchless egress detection rather than a switch inside the device, a DynaLock 6451 Series exit sensor bar for a 36 inch door does that job. The CYREXKIT-ED is the one that lives inside the Corbin or Yale device itself.
11) How do I get the REX wiring from the exit device off the door without a hinge transfer?
A mortise pin transfer is the other route. The RCI 9500/9501 Series is a tamper-resistant mortise pin transfer rated 1.5A at 24VAC. Note that rating against your load: it suits a low-voltage REX signal back to a panel, but it is well under the CYREXKIT-ED switch's own 5A at 120VAC capacity, so don't run a line-voltage load through it.
12) Can I switch a 120VAC load directly with the REX kit or do I need a relay board?
The Command Access CYREXKIT-ED switch is rated 5A at 120VAC and gives you one set of contacts, common, normally open and normally closed, at the exit device. If the door needs several switched outputs from one input, or you want the switching done at the panel instead of inside the device, the Locknetics RDB4 is a four-output relay distribution board that handles that fan-out on its own. The two are not alternatives so much as different points in the circuit: the kit provides the contact at the door, the RDB4 multiplies contacts at the enclosure. Ordering the RDB4 alone will not add REX to a mechanical exit device.
13) What looks like a REX kit in an exit device parts list but is not one?
Two parts get ordered by mistake against the Command Access CYREXKIT-ED, which is the field-installable request to exit switch kit for mechanical Corbin ED4000/5000 and Yale 7000 exit devices. The Securitron SB-MXD exit delay sex bolt is through-bolt mounting hardware for an exit application, not a switch, so it produces no signal. The Dortronics 6510/COV anti-tamper alarm cover fits 6500 series pull stations and 5000 series push buttons and protects a device that is already there rather than adding egress sensing to an exit device. If the requirement on the drawing is a REX contact back to the access control panel, neither one satisfies it.
14) Is the Command Access CYREXKIT-ED rated for commercial use or is it a residential part?
Commercial. It's an electronic access control component intended for commercial exit device applications, and the exit devices it fits, Corbin ED4000/5000 and Yale 7000, are commercial-grade panic hardware. It has no residential application.
15) Can I use the CYREXKIT-ED REX switch to control several devices or relays at once?
The kit gives you one set of dry contacts, common plus NO and NC. To fan that single input out to multiple outputs, you add a relay board, for example the Locknetics RDB4 four-output relay distribution board. Wire the REX contact to the board and take your separate outputs from there rather than trying to load the one switch with multiple circuits.
16) Is the REX sticker in the Command Access CYREXKIT-ED kit required, or can I skip it?
The sticker is included for marking and identification on the opening. It costs nothing to apply and it tells the next technician, and the inspector, that the device carries a request-to-exit switch. Skipping it doesn't affect how the switch works, but on a facility with an access control inspection it's worth putting on.
How fast can I get the Command Access CYREXKIT-ED delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Command Access CYREXKIT-ED come with a warranty?
Absolutely. The Command Access CYREXKIT-ED is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Command Access CYREXKIT-ED?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Command Access CYREXKIT-ED from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.