Dormakaba ES100 Power Supply f...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$856.00
$556.30

Dormakaba ES100 Power Supply for 1 DE Device or 2 LFSC / LFSF Trims

(No reviews yet) Write a Review

Model: ES100

In Stock (leaves warehouse same day if ordered before 3pm ET)

$856.00
$556.30
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks
  • Use with DE exit devices or LFSC/LFSF trim, powers up to 2 devices or 2 trim
  • Input: 120 Volts.
  • Output: 24 VDC, 6 AMP surge for 0.5 seconds, .65 AMP continuous, per zone.
  • Output circuit protection: 3 AMP Push to reset circuit breaker.
  • Enclosure: 8" high × 8" wide × 4" deep NEMA 1 Type enclosure for indoor use with hinged cover and knock-outs.

Manufacturer Resources

Product Specs

Product Group:
Electronic Access Controls
Product Subgroup:
Controllers, Power Supplies and Transformers
Product Type:
Power Supplies
Department:
Door Hardware

Dormakaba ES100 – Frequently Asked Questions

1) How many Dormakaba DE exit devices or LFSC/LFSF trims can the ES100 power supply run?
The ES100 powers one DE exit device, or two LFSC/LFSF electrified trims. It has two zones, each rated 24 VDC at .65 amp continuous with a 6 amp surge for 0.5 seconds. If you have a second DE device on another opening, you need a second supply.
2) Will the Dormakaba ES100 enclosure fit in my electrical closet, and can it be mounted outdoors?
The enclosure measures 8 inches high by 8 inches wide by 4 inches deep, with a hinged cover and knock-outs for conduit. It is a NEMA 1 type box, which is indoor use only. Exterior walls, parking structures, or anywhere it can get wet needs a different rated enclosure.
3) I need to power several electrified openings from one panel. Is the ES100 big enough?
No. The ES100 tops out at .65 amp continuous per zone across two zones, which covers a single DE device or a pair of LFSC/LFSF trims. A multi-door panel needs real amperage and multiple protected outputs: the Altronix AL1024ULACMCB gives 24VDC at 10A across 8 PTC outputs, and the RCI DKPS-2A gives 8 outputs at 12/24VDC 2A. Pick by total load, not door count.
4) The ES100 has no battery backup. Which comparable power supply includes one?
Three carry battery backup in the product itself: the Adams Rite PS-1 is a regulated 1 amp 12/24 volts DC supply with battery backup, the Command Access PS204/204B is a linear supply with 2A at 24VDC and battery backup, and the Detex 10-800 Series is a universal logic controller with a 120VAC/24VDC power supply and battery backup. If the delayed egress opening has to hold its function through a power loss, that requirement drives the selection rather than the ES100's zone output.
5) Will an ES100 run a motorized latch retraction exit device?
Motorized latch retraction has its own supply: the BEST RPSMLR2 Series is a power supply for motorized latch retraction exit devices. The ES100 is specified for one DE exit device or two LFSC/LFSF trims, with 24 VDC at .65 amp continuous per zone and a 6 amp surge for 0.5 seconds. MLR devices draw a sustained motor current rather than a half-second inrush, so match the supply to the device type rather than to the voltage alone.
6) What is the closest equivalent to the Dormakaba ES100 power supply for delayed egress exit devices?
The BEST PS161-6 is the nearest match on the electrical side. It is a power supply for delayed egress exit devices with a 120V input, 12/24V output and 6A capacity, which lines up with the ES100's 120 volt input, 24 VDC output and 6 amp surge rating. The difference to check before you order is device pairing: the ES100 is built to run one DE exit device or two LFSC/LFSF trims, so if the openings are Dormakaba DE hardware, the ES100 is the intended supply and the PS161-6 is the generic delayed egress alternative.
7) I need to power more than two openings from one enclosure. What should I use instead of the ES100?
Look at multi-output boards. The Altronix AL1024ULACMCB is a power supply and access power controller with eight PTC outputs delivering 24VDC at 10A from a 115VAC 60Hz input, and the RCI DKPS-2A gives eight outputs at 12/24VDC and 2A. The ES100 powers up to 2 devices - one DE device or two LFSC/LFSF trims - so a job with six or eight electrified openings on one riser is the case for a distributed-output board rather than additional ES100 units.
8) Does the ES100 have built-in circuit protection, and what happens if the output shorts?
Output protection on the ES100 is a 3 amp push-to-reset circuit breaker. A short or an overload trips it, and you reset it by hand at the board rather than replacing a fuse. That matters on a maintenance call: no spare parts to carry, but somebody has to physically get to the box.
9) Is the ES100 a controller or just a power supply?
Straight power supply. The ES100 converts 120 volt line power to 24 VDC on two zones with a 3 amp resettable breaker, and that is the whole job. It carries no relay logic, timing, or input sequencing. If you need delay timing or a control module in the same box, that is a different animal, like the BEST ELR150 power supply control module or the Detex 10-800 universal logic controller.
10) What do I need to run to the ES100 to get it wired in?
You need a 120 volt AC branch circuit to the box and low voltage runs out to the device. The enclosure comes with knock-outs and a hinged cover, so conduit lands at the box, but the conduit, fittings, and the wire itself are on you. Plan a location an electrician can reach for the line side and a maintenance tech can reach for the reset breaker.
11) I only need to power a single 24VDC electric strike, not an exit device. Is there a smaller supply than the ES100?
Yes. The Command Access PS1 is a 24VDC linear power supply with a 1 amp output, and the SDC 620 Series is a 1 amp regulated and filtered low voltage supply with dual voltage selection. Both are sized for a single small 24VDC load. The ES100 is built around 24 VDC at .65 amp continuous per zone with a 6 amp surge for 0.5 seconds, which is the inrush headroom a motorized or delayed egress device needs and a plain strike does not.
12) Is the ROFU 10305-LA a substitute for the ES100?
No. The ROFU 10305-LA/10306-LA is a tamper resistant power transfer hinge rated 1.5A at 42V in a plastic white finish - it carries current across the gap between frame and door leaf. The ES100 is the source of that current: 120 volt input, 24 VDC output in an 8 inch high by 8 inch wide by 4 inch deep NEMA 1 enclosure with a hinged cover and knock-outs. An electrified opening typically needs both, one to make the power and one to get it into the door.
13) Can I use a plug-in transformer instead of a boxed supply like the ES100?
The ROFU 9126T is a plug in mini power supply rated 12 VDC at 1.5A with a time delay, and the ROFU 9102-12D UL/9102-24D takes a 10/120VAC 60Hz input. A plug-in unit needs a receptacle near the opening and sits exposed, while the ES100 comes in an 8 inch by 8 inch by 4 inch NEMA 1 type indoor enclosure with a hinged cover and knock-outs for conduit, and includes a 3 amp push to reset circuit breaker on the output. Where the spec calls for hard-wired 120 volt supply in a wall-mounted can, the enclosure is the deciding difference.
14) Does the ES100 include the access control logic, or do I need a separate controller?
The ES100 is the power source - 120 volt input, 24 VDC output per zone with a 3 amp push to reset circuit breaker on the output. If the job also needs sequencing or logic, the Detex 10-800 Series is a universal logic controller that carries its own 120VAC/24VDC power supply, and the BEST ELR150 Series is a power supply control module for electronic access control. Those combine the two roles in one enclosure, which matters when panel space in the closet is tight.
15) I need a UL Listed power supply for an intercom-based access control kit. Is the ES100 the right one?
For an intercom entry kit, the Aiphone AC-PS1250 is the supply built for that system - 12V DC at 5A, UL Listed, for AC Series access control kits. The ES100 is scoped to Dormakaba DE exit devices and LFSC/LFSF trims at 24 VDC, so it belongs on the electrified exit hardware rather than on the intercom head end.
16) Which comparable power supply has more continuous output than the ES100 for a larger bank of devices?
The ES100 delivers .65 amp continuous per zone at 24 VDC. If the load list runs past that, the SDC 634 Series is a 4 amp regulated and filtered low voltage supply with dual voltage selection, the Securitron AQS1210 is a switching supply at 12 VDC and 10 amp, and the Altronix AL1024ULACMCB provides 24VDC at 10A. Add up the continuous holding current of every device on the circuit, not the surge, when you size against these.
17) Is there an alternative to the ES100 for an opening with no 120 volt service run to it?
The Securitron BPSS is a boxed solar power supply, which is the option when getting 120 volt branch circuit to the opening is the obstacle - a gate, a detached structure, a remote perimeter door. The ES100 requires a 120 volt input, so where that feed does not exist the choice is between pulling the circuit and using a supply that does not need it.
18) I only have one electrified trim to power. Is there a smaller option than the ES100?
For a single low-draw trim, a 1 amp class supply covers it and takes less wall space. The Command Access PS1 is a 24VDC linear supply with 1 amp output, and the SDC 620 is a 1 amp regulated and filtered supply with dual voltage selection. The ES100 is worth the box when you want its two independent 24 VDC zones for a pair of LFSC/LFSF trims.
19) What do I use to test an electrified device at the opening rather than power it permanently?
The Command Access CAT Field Tester is a 12-24VDC portable power supply compatible with DeWalt, Makita and Milwaukee batteries, meant for bench-checking a device before or during install. The ES100 is a fixed 120 volt input unit in an 8 inch by 8 inch by 4 inch NEMA 1 indoor enclosure and is not a portable tool, so most installers carry the field tester alongside the permanent supply rather than in place of it.
How fast can I get the Dormakaba ES100 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Dormakaba ES100 come with a warranty?
Absolutely. The Dormakaba ES100 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Dormakaba ES100?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Dormakaba ES100 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.