Dual-Laser Infrared Thermometer, 20:1
IR10 - spec sheet
Features
- User definable high/low limits with audible and visual alarms when limits are breached
- Not a medical device; thermometer is NOT intended for use on people or animals.
- Auto Power-Off conserves and extends battery life
- Bright backlit display for working in low ambient lighting conditions
- Includes custom pouch, K-Type probe and battery
- Measurement range for both IR and K-Type probe -40 to 1200-Degree Fahrenheit (-40 to 650-Degree Celsius)
- Soft-touch, over-mold housing; built to withstand a 9.9-Foot (3 m) drop
- U.S. patent D791,624
- Dual Targeting Lasers, 20:1 Distance-to-Spot Ratio; Hi/Low Limits with Simultaneous Audible and Visual Alarms When Limits are Breached; Bright Backlit Display; Works with K-Type Probe Also
- Uses one 9-volt alkaline battery, with battery life expectancy at 8 hours of continuous use with laser and backlight on
- Optical Resolution (Distance-to-Spot) is 20 -1
- Adjustable emissivity from 0.1-1.0 delivers flexibility to address multiple applications
- Dual targeting lasers offer more accurate determination of the area being tested
- Incorporates surface temperature measurement capability using IR emission and can also measure bulk temperatures of air, gas, or liquids using a standard K-Type probe
- IP54 ingress protections for dust and water resistance
- Statistical parameters for measurement event - max/min/avg/diff
Warnings
- Usage of this tester in any way other than that specified by the manufacturer can impair safe operation, resulting in severe injury or death.
- Read, understand and follow all instructions, cautions and warnings attached to and/or packed with all test and measurement devices before each use.
- LASER RADIATION, Class 2 laser. Do NOT stare into beam. Exposing eyes to laser radiation can result in severe and permanent eye injuries. NEVER look directly into the laser beam emitted by this instrument.
- Thermometer is NOT intended for use on people or animals.
IR10 - spec sheet
Manufacturer Resources
Product Specs
- Accuracy:
- IR - 32° F and Above - +/- 3° F or +/- 1.5% (Whichever is Greater); Less Than 32° F - +/- (3.6° F + 0.2° F per Degree); K-Type - 32° F and Above - +/- 2° F or +/-% (Whichever is Greater); Above 32° F - +/- 3° or +/1% (Whichever is Greater)
- Audible Alert:
- Yes
- Auto Calibration:
- No
- Batteries:
- 1 x 9V
- Calculations:
- Min/Max/Difference/Average
- Degree Format:
- F or C
- Depth:
- 4.5600 in
- Display:
- Digital Backlit
- Display Resolution:
- 0.1F (0.1 C)
- Distance To Spot:
- 20 -1
- Drop Protection:
- 3 m
- Height:
- 7.0500 in
- Ingress Protection:
- IP54
- Material:
- Plastic Housing, Electronic Compenents
- Overall Height:
- 4.49" (11.4 cm)
- Overall Length:
- 7" (17.8 cm)
- Overall Width:
- 2.05" (5.2 cm)
- Range:
- -40° to 1200° F (-40° to 650° C)
- Response Time:
- <150ms
- Standard:
- EN 61326-1:2013, EN 608251:2014, 21 CFR 1040.10 and 1040.11, Class II Laser, CE
- Type:
- Dual-Laser Infrared Thermometer
- Weight:
- 0.4630 lbs
- Width:
- 2.0500 in